The effect of interobserver differences in post-implant prostate CT image interpretation on dosimetric parameters.

Ben H Han1, Kent Wallner, Gregory Merrick, Kas Badiozamani, Wayne Butler.   

Abstract

The purpose of this study was to clarify where observers differ in their interpretation of CT scans, and to relate those differences to clinically relevant dosimetric parameters. Twenty unselected patients treated with I-125 or Pd-103 brachytherapy at the Veterans Affairs Puget Sound Health Care System (VAPSHCS) in 2001 were studied. Patients were implanted with I-125 (7 patients, 0.87 mCi/source) or Pd-103 (13 patients, 2.54 U/source). The number of I-125 sources implanted ranged from 52 to 78. The number of Pd-103 sources implanted ranged from 58-144. Post-implant 3 mm CT images were imported into a laptop running Varian Variseed and sent to the four physician investigators, who outlined the prostate independently. Investigators were not coached specifically for this study, beyond their having read prior reports regarding prostate volume determinations. There was moderate interobserver variability in CT volume determination, with the standard deviations as a percent of the mean ranging from 9% to 29% (median: 17%). An average of 14% of implants (range: 5%-20%) would have been judged inadequate based on a minimum V100 of 80%, versus 24% of implants (range: 5%-45%) being judged inadequate based on a minimum D90 of 90% of prescription dose. The greatest variability was seen in prostate length (median standard deviation: 0.57 cm), due to vagaries in base and apical localization. However, the prostatic width and thickness also varied substantially between observers, with median standard deviations of 0.24 and 0.32 cm, respectively. Treatment margin variability was greatest at the anterior border, with a median standard deviation of 0.21 cm +/- 0.10. We believe that CT-based dosimetry, while influenced by CT interpretation, still provides useful general dosimetric calculations, that are likely to be reproducible enough to provide clinically useful information between institutions. The V100 and TMs are less influenced by interobserver CT interpretation variability than is the D90, and may be better suited as interinstitutional quality indices.

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 12852533     DOI: 10.1118/1.1576232

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  4 in total

1.  Results of a dummy run of postimplant dosimetry between multi-institutional centers in prostate brachytherapy with 125I seeds.

Authors:  Manabu Aoki; Atsunori Yorozu; Takushi Dokiya
Journal:  Jpn J Radiol       Date:  2009-12-25       Impact factor: 2.374

2.  CT AND MRI FUSION FOR POSTIMPLANT PROSTATE BRACHYTHERAPY EVALUATION.

Authors:  Ehsan Dehghan; Yi Le; Junghoon Lee; Daniel Y Song; Gabor Fichtinger; Jerry L Prince
Journal:  Proc IEEE Int Symp Biomed Imaging       Date:  2016-06-16

3.  Post-implant computed tomography-magnetic resonance prostate image registration using feature line parallelization and normalized mutual information.

Authors:  Sandra Vidakovic; Hans S Jans; Abe Alexander; Ron S Sloboda
Journal:  J Appl Clin Med Phys       Date:  2006-07-05       Impact factor: 2.102

4.  Determining a reliably visible and inexpensive surface fiducial marker for use in MRI: a research study in a busy Australian Radiology Department.

Authors:  Maree T Izatt; Deborah Lees; Susan Mills; Caroline A Grant; J Paige Little
Journal:  BMJ Open       Date:  2019-08-01       Impact factor: 2.692

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.