Literature DB >> 28816148

Prompt Gamma Imaging for In Vivo Range Verification of Pencil Beam Scanning Proton Therapy.

Yunhe Xie1, El Hassane Bentefour2, Guillaume Janssens2, Julien Smeets2, François Vander Stappen2, Lucian Hotoiu2, Lingshu Yin1, Derek Dolney1, Stephen Avery1, Fionnbarr O'Grady1, Damien Prieels2, James McDonough1, Timothy D Solberg3, Robert A Lustig1, Alexander Lin1, Boon-Keng K Teo4.   

Abstract

PURPOSE: To report the first clinical results and value assessment of prompt gamma imaging for in vivo proton range verification in pencil beam scanning mode. METHODS AND MATERIALS: A stand-alone, trolley-mounted, prototype prompt gamma camera utilizing a knife-edge slit collimator design was used to record the prompt gamma signal emitted along the proton tracks during delivery of proton therapy for a brain cancer patient. The recorded prompt gamma depth detection profiles of individual pencil beam spots were compared with the expected profiles simulated from the treatment plan.
RESULTS: In 6 treatment fractions recorded over 3 weeks, the mean (± standard deviation) range shifts aggregated over all spots in 9 energy layers were -0.8 ± 1.3 mm for the lateral field, 1.7 ± 0.7 mm for the right-superior-oblique field, and -0.4 ± 0.9 mm for the vertex field.
CONCLUSIONS: This study demonstrates the feasibility and illustrates the distinctive benefits of prompt gamma imaging in pencil beam scanning treatment mode. Accuracy in range verification was found in this first clinical case to be better than the range uncertainty margin applied in the treatment plan. These first results lay the foundation for additional work toward tighter integration of the system for in vivo proton range verification and quantification of range uncertainties.
Copyright © 2017 Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2017        PMID: 28816148     DOI: 10.1016/j.ijrobp.2017.04.027

Source DB:  PubMed          Journal:  Int J Radiat Oncol Biol Phys        ISSN: 0360-3016            Impact factor:   7.038


  24 in total

Review 1.  Image guidance in proton therapy for lung cancer.

Authors:  Miao Zhang; Wei Zou; Boon-Keng Kevin Teo
Journal:  Transl Lung Cancer Res       Date:  2018-04

Review 2.  In vivo range verification in particle therapy.

Authors:  Katia Parodi; Jerimy C Polf
Journal:  Med Phys       Date:  2018-11       Impact factor: 4.071

Review 3.  Status and innovations in pre-treatment CT imaging for proton therapy.

Authors:  Patrick Wohlfahrt; Christian Richter
Journal:  Br J Radiol       Date:  2019-11-11       Impact factor: 3.039

4.  Compact Method for Proton Range Verification Based on Coaxial Prompt Gamma-Ray Monitoring: a Theoretical Study.

Authors:  F Hueso-González; T Bortfeld
Journal:  IEEE Trans Radiat Plasma Med Sci       Date:  2019-07-23

5.  Fast In Situ Image Reconstruction for Proton Radiography.

Authors:  Caesar E Ordoñez; Nicholas T Karonis; Kirk L Duffin; John R Winans; Ethan A DeJongh; Don F DeJongh; George Coutrakon; Nicole F Myers; Mark Pankuch; James S Welsh
Journal:  J Radiat Oncol       Date:  2019-05-25

Review 6.  Adaptive proton therapy.

Authors:  Harald Paganetti; Pablo Botas; Gregory C Sharp; Brian Winey
Journal:  Phys Med Biol       Date:  2021-11-15       Impact factor: 3.609

7.  A full-scale clinical prototype for proton range verification using prompt gamma-ray spectroscopy.

Authors:  Fernando Hueso-González; Moritz Rabe; Thomas A Ruggieri; Thomas Bortfeld; Joost M Verburg
Journal:  Phys Med Biol       Date:  2018-09-17       Impact factor: 3.609

Review 8.  Latest developments in in-vivo imaging for proton therapy.

Authors:  Katia Parodi
Journal:  Br J Radiol       Date:  2019-12-12       Impact factor: 3.039

9.  Prompt gamma imaging for the identification of regional proton range deviations due to anatomic change in a heterogeneous region.

Authors:  Yunhe Xie; Johannes Petzoldt; Guillaume Janssens; Fionnbarr O'Grady; Lingshu Yin; El Hassane Bentefour; Julien Smeets; Damien Prieels; Robert A Lustig; Alexander Lin; Boon-Keng Teo
Journal:  Br J Radiol       Date:  2020-10-06       Impact factor: 3.039

10.  Carbon-11 and Carbon-12 beam range verifications through prompt gamma and annihilation gamma measurements: Monte Carlo simulations.

Authors:  Ananta Raj Chalise; Yujie Chi; Youfang Lai; Yiping Shao; Mingwu Jin
Journal:  Biomed Phys Eng Express       Date:  2020-09-29
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.