Literature DB >> 28812129

[Device-based remote monitoring : Current evidence].

David Duncker1, Roman Michalski1, Johanna Müller-Leisse1, Christos Zormpas1, Thorben König1, Christian Veltmann2.   

Abstract

Telemedicine is increasingly used in clinical cardiology. It offers early detection of arrhythmias, technical device follow-up and support of heart failure management. Regarding technical device follow-up, remote monitoring significantly reduces usage of the health care system. Furthermore, remote monitoring is associated with a significantly reduced time from device malfunction to physician's perception of the event. Using remote monitoring, inappropriate ICD (implantable cardioverter defibrillator) shocks can be significantly reduced compared to routine in-office follow-up. In retrospective studies and meta-analyses a prognostic benefit with respect to mortality has been shown. Device-based detection of atrial fibrillation and atrial high rate episodes is feasible. However, clinical relevance is currently studied in prospective randomized clinical trials. Heart failure management based on surrogate parameters has not been shown to significantly improve outcome. However, therapeutic management based on pulmonary artery pressure has been shown to significantly reduce morbidity and mortality. This review offers a comprehensive overview on the role of remote monitoring in heart failure management, technical device follow-up and detection of atrial fibrillation and atrial high rate episodes.

Entities:  

Keywords:  Atrial fibrillation; Cardiac implantable electronic devices; Follow-up; Heart failure; Telemedicine

Mesh:

Year:  2017        PMID: 28812129     DOI: 10.1007/s00399-017-0521-3

Source DB:  PubMed          Journal:  Herzschrittmacherther Elektrophysiol        ISSN: 0938-7412


  44 in total

1.  Randomized trial of atrial arrhythmia monitoring to guide anticoagulation in patients with implanted defibrillator and cardiac resynchronization devices.

Authors:  David T Martin; Malcolm M Bersohn; Albert L Waldo; Mark S Wathen; Wassim K Choucair; Gregory Y H Lip; John Ip; Richard Holcomb; Joseph G Akar; Jonathan L Halperin
Journal:  Eur Heart J       Date:  2015-04-23       Impact factor: 29.983

2.  HRS Expert Consensus Statement on remote interrogation and monitoring for cardiovascular implantable electronic devices.

Authors:  David Slotwiner; Niraj Varma; Joseph G Akar; George Annas; Marianne Beardsall; Richard I Fogel; Nestor O Galizio; Taya V Glotzer; Robin A Leahy; Charles J Love; Rhondalyn C McLean; Suneet Mittal; Loredana Morichelli; Kristen K Patton; Merritt H Raitt; Renato Pietro Ricci; John Rickard; Mark H Schoenfeld; Gerald A Serwer; Julie Shea; Paul Varosy; Atul Verma; Cheuk-Man Yu
Journal:  Heart Rhythm       Date:  2015-05-14       Impact factor: 6.343

3.  Efficacy and safety of automatic remote monitoring for implantable cardioverter-defibrillator follow-up: the Lumos-T Safely Reduces Routine Office Device Follow-up (TRUST) trial.

Authors:  Niraj Varma; Andrew E Epstein; Anand Irimpen; Robert Schweikert; Charles Love
Journal:  Circulation       Date:  2010-07-12       Impact factor: 29.690

4.  Wireless pulmonary artery haemodynamic monitoring in chronic heart failure: a randomised controlled trial.

Authors:  William T Abraham; Philip B Adamson; Robert C Bourge; Mark F Aaron; Maria Rosa Costanzo; Lynne W Stevenson; Warren Strickland; Suresh Neelagaru; Nirav Raval; Steven Krueger; Stanislav Weiner; David Shavelle; Bradley Jeffries; Jay S Yadav
Journal:  Lancet       Date:  2011-02-19       Impact factor: 79.321

Review 5.  The Wearable Cardioverter/Defibrillator - Toy Or Tool?

Authors:  David Duncker; Christian Veltmann
Journal:  J Atr Fibrillation       Date:  2016-04-30

6.  A randomized study of remote monitoring and fluid monitoring for the management of patients with implanted cardiac arrhythmia devices.

Authors:  Lars Lüthje; Dirk Vollmann; Joachim Seegers; Christian Sohns; Gerd Hasenfuß; Markus Zabel
Journal:  Europace       Date:  2015-05-17       Impact factor: 5.214

7.  Effects of remote monitoring on clinical outcomes and use of healthcare resources in heart failure patients with biventricular defibrillators: results of the MORE-CARE multicentre randomized controlled trial.

Authors:  Giuseppe Boriani; Antoine Da Costa; Aurelio Quesada; Renato Pietro Ricci; Stefano Favale; Gabriele Boscolo; Nicolas Clementy; Valentina Amori; Lorenza Mangoni di S Stefano; Haran Burri
Journal:  Eur J Heart Fail       Date:  2016-08-28       Impact factor: 15.534

8.  A randomized study of remote follow-up of implantable cardioverter defibrillators: safety and efficacy report of the ECOST trial.

Authors:  Laurence Guédon-Moreau; Dominique Lacroix; Nicolas Sadoul; Jacques Clémenty; Claude Kouakam; Jean-Sylvain Hermida; Etienne Aliot; Michel Boursier; Olivier Bizeau; Salem Kacet
Journal:  Eur Heart J       Date:  2012-12-13       Impact factor: 29.983

9.  The MOnitoring Resynchronization dEvices and CARdiac patiEnts (MORE-CARE) randomized controlled trial: phase 1 results on dynamics of early intervention with remote monitoring.

Authors:  Giuseppe Boriani; Antoine Da Costa; Renato Pietro Ricci; Aurelio Quesada; Stefano Favale; Saverio Iacopino; Francesco Romeo; Arnaldo Risi; Lorenza Mangoni di S Stefano; Xavier Navarro; Mauro Biffi; Massimo Santini; Haran Burri
Journal:  J Med Internet Res       Date:  2013-08-21       Impact factor: 5.428

10.  Smart detection of atrial fibrillation†.

Authors:  Lian Krivoshei; Stefan Weber; Thilo Burkard; Anna Maseli; Noe Brasier; Michael Kühne; David Conen; Thomas Huebner; Andrea Seeck; Jens Eckstein
Journal:  Europace       Date:  2017-05-01       Impact factor: 5.214

View more
  1 in total

1.  Initial experience with telemonitoring in left ventricular assist device patients.

Authors:  Stephan Hohmann; Christian Veltmann; David Duncker; Thorben König; Dominik Berliner; Jasmin Hanke; Günes Dogan; Anamika Chatterjee; Christina Feldmann; Bryan Lynch; Daniel Burkhoff; Axel Haverich; Johann Bauersachs; Jan D Schmitto
Journal:  J Thorac Dis       Date:  2019-04       Impact factor: 2.895

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.