Literature DB >> 27909495

The Wearable Cardioverter/Defibrillator - Toy Or Tool?

David Duncker1, Christian Veltmann1.   

Abstract

After the success story of implantable cardioverter/defibrillator systems, prevention of sudden cardiac death (SCD) remains one of the main duties in cardiology. For patients with unkown or transient risk profile for SCD, a wearable cardioverter/defibrillator (WCD) has been established for temporary and effective prevention of sudden arrhythmic death. Several studies have shown safety and efficacy of the WCD, even though randomized studies proving a mortality benefit are still lacking. This review provides an overview of actual WCD data and usage, special indications and possible risks and complications. WCD use is effective and adequate for temporary prevention of SCD in chosen populations. In particular, it provides secured time for sophisticated risk stratification to identify patients at persistent risk for SCD. Nevertheless, prospective randomized trials seem mandatory to prove a prognostic relevance and the economic value of this device.

Entities:  

Keywords:  Sudden Cardiac Death; Ventricular Arrhythmia; Wearable Cardioverter/Defibrillator

Year:  2016        PMID: 27909495      PMCID: PMC5089470          DOI: 10.4022/jafib.1367

Source DB:  PubMed          Journal:  J Atr Fibrillation        ISSN: 1941-6911


  51 in total

1.  Risk stratification for primary implantation of a cardioverter-defibrillator in patients with ischemic left ventricular dysfunction.

Authors:  Ilan Goldenberg; Anant K Vyas; W Jackson Hall; Arthur J Moss; Hongyue Wang; Hua He; Wojciech Zareba; Scott McNitt; Mark L Andrews
Journal:  J Am Coll Cardiol       Date:  2008-01-22       Impact factor: 24.094

2.  Prophylactic implantation of a defibrillator in patients with myocardial infarction and reduced ejection fraction.

Authors:  Arthur J Moss; Wojciech Zareba; W Jackson Hall; Helmut Klein; David J Wilber; David S Cannom; James P Daubert; Steven L Higgins; Mary W Brown; Mark L Andrews
Journal:  N Engl J Med       Date:  2002-03-19       Impact factor: 91.245

3.  Non-evidence-based ICD implantations in the United States.

Authors:  Sana M Al-Khatib; Anne Hellkamp; Jeptha Curtis; Daniel Mark; Eric Peterson; Gillian D Sanders; Paul A Heidenreich; Adrian F Hernandez; Lesley H Curtis; Stephen Hammill
Journal:  JAMA       Date:  2011-01-05       Impact factor: 56.272

4.  Early risk of mortality after coronary artery revascularization in patients with left ventricular dysfunction and potential role of the wearable cardioverter defibrillator.

Authors:  Edwin T Zishiri; Sarah Williams; Edmond M Cronin; Eugene H Blackstone; Stephen G Ellis; Eric E Roselli; Nicholas G Smedira; A Marc Gillinov; Jo Ann Glad; Patrick J Tchou; Steven J Szymkiewicz; Mina K Chung
Journal:  Circ Arrhythm Electrophysiol       Date:  2012-12-28

5.  Heart rhythm at the time of death documented by an implantable loop recorder.

Authors:  Uffe Jakob Ortved Gang; Christian Jøns; Rikke Mørch Jørgensen; Steen Zabell Abildstrøm; Jens Haarbo; Marc D Messier; Heikki V Huikuri; Poul Erik Bloch Thomsen
Journal:  Europace       Date:  2009-12-16       Impact factor: 5.214

6.  Use of a wearable defibrillator in terminating tachyarrhythmias in patients at high risk for sudden death: results of the WEARIT/BIROAD.

Authors:  Arthur M Feldman; Helmut Klein; Patrick Tchou; Srinivas Murali; W Jackson Hall; Donna Mancini; John Boehmer; Mark Harvey; M Stephen Heilman; Steven J Szymkiewicz; Arthur J Moss
Journal:  Pacing Clin Electrophysiol       Date:  2004-01       Impact factor: 1.976

7.  Evaluation of the effectiveness of a wearable cardioverter defibrillator detection algorithm.

Authors:  Katie A Dillon; Steven J Szymkiewicz; Thomas E Kaib
Journal:  J Electrocardiol       Date:  2010 Jan-Feb       Impact factor: 1.438

8.  Wearable cardioverter-defibrillator use in patients perceived to be at high risk early post-myocardial infarction.

Authors:  Andrew E Epstein; William T Abraham; Nicole R Bianco; Karl B Kern; Michael Mirro; Sunil V Rao; Edward K Rhee; Scott D Solomon; Steven J Szymkiewicz
Journal:  J Am Coll Cardiol       Date:  2013-07-31       Impact factor: 24.094

Review 9.  The cost-effectiveness of primary prophylactic implantable defibrillator therapy in patients with ischaemic or non-ischaemic heart disease: a European analysis.

Authors:  Tim Smith; Luc Jordaens; Dominic A M J Theuns; Pascal F van Dessel; Arthur A Wilde; M G Myriam Hunink
Journal:  Eur Heart J       Date:  2012-05-14       Impact factor: 29.983

10.  First experience with the wearable cardioverter defibrillator in the Netherlands.

Authors:  R E Knops; K M Kooiman; J N Ten Sande; J R de Groot; A A M Wilde
Journal:  Neth Heart J       Date:  2012-02       Impact factor: 2.380

View more
  12 in total

Review 1.  [The wearable cardioverter/defibrillator : Temporary protection from sudden cardiac death].

Authors:  D Duncker; J Bauersachs; C Veltmann
Journal:  Internist (Berl)       Date:  2016-09       Impact factor: 0.743

Review 2.  Detection and management of arrhythmias in peripartum cardiomyopathy.

Authors:  Julian Hoevelmann; Lina Hähnle; Julia Hähnle; Karen Sliwa; Charle Viljoen
Journal:  Cardiovasc Diagn Ther       Date:  2020-04

3.  Ventricular arrhythmias in patients with newly diagnosed nonischemic cardiomyopathy: Insights from the PROLONG study.

Authors:  David Duncker; Thorben König; Stephan Hohmann; Johann Bauersachs; Christian Veltmann
Journal:  Clin Cardiol       Date:  2017-03-23       Impact factor: 2.882

Review 4.  [Device-based remote monitoring : Current evidence].

Authors:  David Duncker; Roman Michalski; Johanna Müller-Leisse; Christos Zormpas; Thorben König; Christian Veltmann
Journal:  Herzschrittmacherther Elektrophysiol       Date:  2017-08-15

Review 5.  [Wearable defibrillator : Current evidence].

Authors:  David Duncker; Christian Veltmann
Journal:  Herzschrittmacherther Elektrophysiol       Date:  2018-10-24

Review 6.  [Ventricular arrhythmias : What has been confirmed in therapy?]

Authors:  D Duncker; J Bauersachs; C Veltmann
Journal:  Internist (Berl)       Date:  2017-12       Impact factor: 0.743

7.  Comparison of the Outcome of Patients Protected by the Wearable Cardioverter Defibrillator (WCD) for <90 Wear Days versus ≥90 Wear Days.

Authors:  Tobias C Dreher; Ibrahim El-Battrawy; Susanne RÖger; Stephanie L Rosenkaimer; Stefan Gerhards; JÜrgen Kuschyk; Martin Borggrefe; Ibrahim Akin
Journal:  In Vivo       Date:  2020 Nov-Dec       Impact factor: 2.155

8.  Avoiding Untimely Implantable Cardioverter/Defibrillator Implantation by Intensified Heart Failure Therapy Optimization Supported by the Wearable Cardioverter/Defibrillator-The PROLONG Study.

Authors:  David Duncker; Thorben König; Stephan Hohmann; Johann Bauersachs; Christian Veltmann
Journal:  J Am Heart Assoc       Date:  2017-01-17       Impact factor: 5.501

9.  Risk for life-threatening arrhythmia in newly diagnosed peripartum cardiomyopathy with low ejection fraction: a German multi-centre analysis.

Authors:  David Duncker; Ralf Westenfeld; Torsten Konrad; Tobias Pfeffer; Carlos A Correia de Freitas; Roman Pfister; Dierk Thomas; Alexander Fürnkranz; René P Andrié; Andreas Napp; Jörn Schmitt; Laszlo Karolyi; Reza Wakili; Denise Hilfiker-Kleiner; Johann Bauersachs; Christian Veltmann
Journal:  Clin Res Cardiol       Date:  2017-03-08       Impact factor: 5.460

Review 10.  Role of the Wearable Defibrillator in Newly Diagnosed Heart Failure.

Authors:  David Duncker; Christian Veltmann
Journal:  Curr Heart Fail Rep       Date:  2018-12
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.