| Literature DB >> 28798994 |
Mustafa S Rashid1, Sheweidin Aziz2, Syed Haydar2, Simon S Fleming3, Amit Datta2.
Abstract
INTRODUCTION: Radiation exposure from intra-operative fluoroscopy in orthopaedic trauma surgery is a common occupational hazard. References for fluoroscopy use in the operating room for commonly performed operations have not been reported adequately. This study aimed to report appropriate intra-operative fluoroscopy use in orthopaedic trauma and compare the effect of surgery type and surgeon grade on radiation exposure.Entities:
Keywords: Exposure; Fluoroscopy; Radiation; Trauma operating room; X-ray
Mesh:
Year: 2017 PMID: 28798994 PMCID: PMC5754436 DOI: 10.1007/s00590-017-2020-y
Source DB: PubMed Journal: Eur J Orthop Surg Traumatol ISSN: 1633-8065
Frequency and type of trauma operations requiring fluoroscopy use including median dose area product, screening time, and number of fluoroscopy images taken for trauma cases where n > 9
|
| Median DAP (mGy/cm2) | Median screening time (mm:ss) | Median no. of fluoroscopy images | |
|---|---|---|---|---|
| Neck of femur (DHS) | 190 | 667.5 | 00:36 | 65 |
| Distal radius (MUA + K-wires) | 139 | 25.2 | 00:25 | 45 |
| PFN (short) | 75 | 1040 | 00:49 | 109 |
| Distal radius (ORIF) | 50 | 27.35 | 00:23 | 45 |
| IM femur nail (long) | 39 | 1720 | 02:36 | 243 |
| Neck of femur (cannulated screws) | 35 | 881 | 00:56 | 113 |
| Bimalleolar (ORIF) | 33 | 64.5 | 00:22 | 42 |
| Neck of femur (MUA-THR) | 29 | 186 | 00:08 | 12 |
| Forearm (MUA) | 24 | 11.05 | 00:09 | 17 |
| Fibula (ORIF) | 22 | 37.35 | 00:15 | 29 |
| Tibia (ORIF) | 19 | 185 | 00:43 | 84 |
| Distal radius (MUA) | 18 | 11.25 | 00:10 | 16 |
| Ankle (MUA) | 16 | 47.3 | 00:10 | 21 |
| Tibia (IM nail) | 14 | 359.5 | 01:44 | 202 |
| Femur (ORIF) | 14 | 613 | 01:14 | 133 |
| Elbow (MUA + pinning supracondylar) | 13 | 87 | 00:55 | 107 |
| Forearm (ORIF) | 12 | 24.35 | 00:18 | 34 |
| Elbow (MUA) | 12 | 33.85 | 00:11 | 17 |
| Elbow (ORIF) | 12 | 81.25 | 00:18 | 37 |
| Medial malleolus (ORIF) | 11 | 57 | 00:15 | 29 |
| Knee (ORIF-tibial plateau) | 11 | 225 | 00:26 | 52 |
| Tibia/fibula (MUA) | 10 | 37.85 | 00:16 | 33 |
| Humerus (ORIF) | 10 | 139.5 | 00:23 | 42 |
| Total | 808 |
Evidence-based recommendations for surgeons, radiographers, and institutions for minimizing ionization radiation exposure in conventional fluoroscopy in trauma operating room
| Personnel responsible | Recommendation | Reference |
|---|---|---|
| Surgeons | Reduce number of repeat fluoroscopic images required by consideration and clear communication | [ |
| Radiographers | Limitation of field size to area of interest (collimation) | [ |
| Institutions | Provide and maintain personal protective equipment including lead gowns, thyroid shields, and eye goggles | [ |
Reference radiation exposure values (median and 75th centile) for five commonest trauma operations using dose area product, screening time, and number of II images taken
|
| Median DAP (mGy/cm2) | 75th centile DAP (mGy/cm2) | Median screening time (mm:ss) | Median no. of fluoroscopy images | 75th centile no. of fluoroscopy images | |
|---|---|---|---|---|---|---|
| Neck of femur (DHS) | 190 | 667.5 | 20.2 | 00:36 | 65 | 88.5 |
| Distal radius (MUA + K-wires) | 139 | 25.2 | 0.43 | 00:25 | 45 | 69 |
| PFN (short) | 75 | 1040 | 24.45 | 00:49 | 109 | 143 |
| Distal radius (ORIF) | 50 | 27.35 | 0.47 | 00:23 | 45 | 58 |
| IM femur nail (long) | 39 | 1720 | 45.3 | 02:36 | 243 | 290.5 |