Literature DB >> 26360538

Reduction of Radiation Exposure From C-Arm Fluoroscopy During Orthopaedic Trauma Operations With Introduction of Real-Time Dosimetry.

Rita Baumgartner1, Kiley Libuit, Dennis Ren, Omar Bakr, Nathan Singh, Utku Kandemir, Meir Tibi Marmor, Saam Morshed.   

Abstract

OBJECTIVES: The use of fluoroscopy for indirect guidance in orthopaedic trauma surgery has increased. The purpose of this investigation was to assess how real-time visualization of radiation exposure impacts dose levels during orthopaedic trauma operations.
DESIGN: Observational comparative study.
SETTING: Level 1 trauma center orthopaedic trauma surgery operating room. PATIENTS/PARTICIPANTS: The participants in this study were 83 patients with fractures of the ankle, tibia, femur, or acetabulum receiving definitive surgical fixation of their fracture; children under 18 years of age were excluded from the study. Fellowship trained orthopaedic trauma surgeons, resident orthopaedic surgeons, radiology technicians, and scrub nurses involved in the operations on included fracture patients were also participants. INTERVENTION: Real-time radiation exposure feedback from the Philips DoseAware device. MAIN OUTCOME MEASUREMENTS: Radiation exposure from fluoroscopy compared between phase 1, during which participants were blinded to exposure levels, and phase 2, during which participants were able to see exposure levels in real time.
RESULTS: Overall mean radiation exposure was decreased by 60% in phase 2 compared with phase 1 (P = 0.023). Mean surgeon (MS; average of primary and assistant surgeon) and mean nonsurgeon personnel (average of x-ray technician, scrub nurse, and patient) radiation exposures were decreased from phase 1 to phase 2, by 58% and 80%, respectively (MS, P = 0.034; mean nonsurgeon personnel, P = 0.043). From phase 1 to phase 2, MS radiation for femoral shaft fractures decreased by 80% or 162.0 μSv (P = 0.02) and by 81% or 128.9 μSv (P = 0.014) for acetabular fractures. DISCUSSION: Our data demonstrate that real-time visualization of radiation exposure during orthopaedic trauma operations can decrease radiation exposure in the highest exposure cases. Further research is necessary to determine whether the reduction in radiation exposure is sustained over time and to understand how real-time radiation exposure data mitigates exposure. LEVEL OF EVIDENCE: Therapeutic Level III. See Instructions for Authors for a complete description of levels of evidence.

Entities:  

Mesh:

Year:  2016        PMID: 26360538     DOI: 10.1097/BOT.0000000000000442

Source DB:  PubMed          Journal:  J Orthop Trauma        ISSN: 0890-5339            Impact factor:   2.512


  9 in total

1.  CORR Insights(®): A Radiation Safety Training Program Results in Reduced Radiation Exposure for Orthopaedic Residents Using the Mini C-arm.

Authors:  Peter D Fabricant
Journal:  Clin Orthop Relat Res       Date:  2015-12-08       Impact factor: 4.176

2.  Enabling machine learning in X-ray-based procedures via realistic simulation of image formation.

Authors:  Mathias Unberath; Jan-Nico Zaech; Cong Gao; Bastian Bier; Florian Goldmann; Sing Chun Lee; Javad Fotouhi; Russell Taylor; Mehran Armand; Nassir Navab
Journal:  Int J Comput Assist Radiol Surg       Date:  2019-06-11       Impact factor: 2.924

3.  Radiation exposure for the surgical team in a hybrid-operating room.

Authors:  Konard Schuetze; A Eickhoff; C Dehner; M Schultheiss; F Gebhard; P H Richter
Journal:  J Robot Surg       Date:  2018-05-10

4.  Factors influencing radiation exposure during internal fixation of hip fractures.

Authors:  G A Kelly; F E Rowan; C Hurson
Journal:  Eur J Orthop Surg Traumatol       Date:  2017-04-10

5.  Validation of the Artificial Floor Technique in First Metatarsophalangeal Joint Arthrodesis.

Authors:  John T Strony; Alexander S Rascoe; Randall E Marcus
Journal:  Clin Orthop Relat Res       Date:  2022-05-18       Impact factor: 4.755

6.  Radiation Safety Knowledge and Practices: Is the Indian Orthopaedic Community Well-informed?

Authors:  Ashish S Ranade; Gauri A Oka; Anurag Daxini; Gaurav Ardawatia; Debkumar Majumder; Shivashankar Bhaskaran
Journal:  Indian J Orthop       Date:  2020-07-31       Impact factor: 1.251

7.  Intra-operative fluoroscopic radiation exposure in orthopaedic trauma theatre.

Authors:  Mustafa S Rashid; Sheweidin Aziz; Syed Haydar; Simon S Fleming; Amit Datta
Journal:  Eur J Orthop Surg Traumatol       Date:  2017-08-10

8.  The Effect of C-Arm Mobility and Field of Vision on Radiation Exposure in the Treatment of Proximal Femoral Fractures: A Randomized Clinical Trial.

Authors:  Mahmut Kalem; Kerem Başarır; Hakan Kocaoğlu; Ercan Şahin; Hakan Kınık
Journal:  Biomed Res Int       Date:  2018-03-27       Impact factor: 3.411

9.  Similar function and complications for patients with short versus long hip nailing for unstable pertrochanteric fractures.

Authors:  Ioannis P Galanopoulos; Andreas F Mavrogenis; Panayiotis D Megaloikonomos; Christos T Vottis; Evanthia Mitsiokapa; Panayiotis Koulouvaris; Dimitrios S Mastrokalos; Panayiotis J Papagelopoulos; Vasilios A Kontogeorgakos
Journal:  SICOT J       Date:  2018-06-15
  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.