Repeated use of X-rays in orthopedic surgery poses the problem of irradiation of patient and caregivers. Seven common minimally invasive bone trauma surgical procedures requiring image intensifier use were investigated: percutaneous K-wire fixation of the wrist, minimally invasive fixation plating of the wrist, percutaneous intramedullary nailing of the tibia and of the femur, short and long trochanteric nail fixation of trochanteric and sub-trochanteric fracture, and percutaneous fixation of thoracolumbar fracture. The study analyzed three parameters: dose area product (DAP), radiation duration, and skin entrance dose (SED). Data were collected from 15 successive implementations of each procedure. The aim of the study was to establish a database for this kind of bone trauma surgery and a hierarchy of the X-ray doses delivered. Percutaneous spinal osteosynthesis involved the highest dose, followed in decreasing order by long trochanteric nailing, femoral nailing, short trochanteric nailing, tibial nailing, wrist K-wire fixation and frontal wrist plate osteosynthesis. One short trochanteric nail procedure delivered the same DAP as 13 wrist K-wire fixation procedures, and one spinal osteosynthesis was equivalent to 13 short trochanteric nail or 174 wrist K-wire procedures. The anatomic area X-rayed appeared to be the main radiation dose factor. A database was established, but actual patient and staff radiation levels remained unknown.
Copyright © 2011 Elsevier Masson SAS. All rights reserved.

Entities:  

Mesh:

Year:  2011        PMID: 21943776     DOI: 10.1016/j.otsr.2011.03.024

Source DB:  PubMed          Journal:  Orthop Traumatol Surg Res        ISSN: 1877-0568            Impact factor:   2.256


  12 in total

1.  Patient dose reference levels in surgery: a multicenter study.

Authors:  J Greffier; C Etard; O Mares; F Pereira; D Defez; C Duverger; P Branchereau; J P Beregi; R Coulomb; A Larbi
Journal:  Eur Radiol       Date:  2018-08-01       Impact factor: 5.315

2.  Influence of direct radiography in decision making during orthopaedic trauma surgery: A prospective study.

Authors:  Ibrahim Alper Yavuz; Utku Gurhan; Erman Ceyhan; Fatih Inci; Ozdamar Fuad Oken; Ahmet Ozgur Yildirim; Ozlem Ozkale Yavuz
Journal:  J Orthop       Date:  2022-10-07

3.  Reducing intraoperative duration and ionising radiation exposure during the insertion of distal locking screws of intramedullary nails: a small-scale study comparing the current fluoroscopic method against radiation-free, electromagnetic navigation.

Authors:  Darren Grimwood; Jane Harvey-Lloyd
Journal:  Eur J Orthop Surg Traumatol       Date:  2016-08-25

4.  Electromagnetic distal targeting system does not reduce the overall operative time of the intramedullary nailing for humeral shaft fractures.

Authors:  Lawrence Camarda; Stefania Zini; Marcello Butera; Sabastin Giambartino; Ugo Mattaliano; Francesco Raso; Roberto Sciortino; Michele D'Arienzo
Journal:  J Orthop       Date:  2018-08-24

5.  Comparison of our self-designed rotary self-locking intramedullary nail and interlocking intramedullary nail in the treatment of long bone fractures.

Authors:  Bailian Liu; Ying Xiong; Hong Deng; Shao Gu; Fu Jia; Qunhui Li; Daxing Wang; Xuewen Gan; Wei Liu
Journal:  J Orthop Surg Res       Date:  2014-07-21       Impact factor: 2.359

6.  Intra-operative fluoroscopic radiation exposure in orthopaedic trauma theatre.

Authors:  Mustafa S Rashid; Sheweidin Aziz; Syed Haydar; Simon S Fleming; Amit Datta
Journal:  Eur J Orthop Surg Traumatol       Date:  2017-08-10

7.  Orthopedic surgeons' knowledge regarding risk of radiation exposition: a survey analysis.

Authors:  Nejat Tunçer; Ersin Kuyucu; Şafak Sayar; Gökhan Polat; İrem Erdil; İbrahim Tuncay
Journal:  SICOT J       Date:  2017-04-07

8.  The Effect of C-Arm Mobility and Field of Vision on Radiation Exposure in the Treatment of Proximal Femoral Fractures: A Randomized Clinical Trial.

Authors:  Mahmut Kalem; Kerem Başarır; Hakan Kocaoğlu; Ercan Şahin; Hakan Kınık
Journal:  Biomed Res Int       Date:  2018-03-27       Impact factor: 3.411

9.  Radiation Exposure in Patients with Isolated Limb Trauma: Acceptable or Are We Imaging Too Much?

Authors:  James A Wheeler; Natasha Weaver; Zsolt J Balogh; Herwig Drobetz; Andrew Kovendy; Natalie Enninghorst
Journal:  J Clin Med       Date:  2020-11-09       Impact factor: 4.241

10.  Does a fluoro-assisted direct anterior approach for total hip arthroplasty pose an excessive risk of radiation exposure to the surgeon?

Authors:  Yuta Jinnai; Tomonori Baba; Xu Zhuang; Hiroki Tanabe; Sammy Banno; Taiji Watari; Yasuhiro Homma; Kazuo Kaneko
Journal:  SICOT J       Date:  2020-02-18
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.