Literature DB >> 1416705

Ionising radiation: are orthopaedic surgeons at risk?

G L Smith1, T W Briggs, C B Lavy, H Nordeen.   

Abstract

Modern orthopaedic trauma practice involves increased exposure of the surgeon to ionising radiation. However, there have been no studies to investigate whether the doses received are within limits for non-classified workers. In this study, whole body, eye and extremity, namely hand, doses were measured in six orthopaedic surgeons during trauma cases requiring the use of X-rays in theatre. None of the subjects approached the recommended maximum dose levels for either the whole body, eyes or hands. This finding is reassuring. In orthopaedics, the limiting dose is that to the hands. This differs from previously studied groups, such as radiologists and cardiologists, in whom the limiting factor is the dose to the lens of the eye. Although current precautions appear to be adequate, safe practice in the future will depend on continuing vigilance and repetition of studies similar to this one as techniques and workloads change.

Entities:  

Mesh:

Year:  1992        PMID: 1416705      PMCID: PMC2497674     

Source DB:  PubMed          Journal:  Ann R Coll Surg Engl        ISSN: 0035-8843            Impact factor:   1.891


  2 in total

1.  An investigation of the radiation dose to staff during cardiac radiological studies.

Authors:  S P Jeans; K Faulkner; H G Love; R A Bardsley
Journal:  Br J Radiol       Date:  1985-05       Impact factor: 3.039

2.  An assessment of the radiation dose received by staff using fluoroscopic equipment.

Authors:  K Faulkner; B M Moores
Journal:  Br J Radiol       Date:  1982-04       Impact factor: 3.039

  2 in total
  11 in total

1.  Ionising radiation exposure to orthopaedic trainees: the effect of sub-specialty training.

Authors:  M J Oddy; C H Aldam
Journal:  Ann R Coll Surg Engl       Date:  2006-05       Impact factor: 1.891

2.  Radiation exposure to the orthopaedic surgeon during periacetabular osteotomy.

Authors:  Inger Mechlenburg; Henrik Daugaard; Kjeld Søballe
Journal:  Int Orthop       Date:  2008-10-29       Impact factor: 3.075

3.  Ionising radiation: are orthopaedic surgeons' offspring at risk?

Authors:  H G Zadeh; T W Briggs
Journal:  Ann R Coll Surg Engl       Date:  1997-05       Impact factor: 1.891

4.  Value of intraoperative image intensifier prints in trauma surgery.

Authors:  R L Williams; F S Haddad; A J Clarke
Journal:  Ann R Coll Surg Engl       Date:  1996-11       Impact factor: 1.891

5.  Using a dedicated spine radiology technologist is associated with reduced fluoroscopy time, radiation dose, and surgical time in pediatric spinal deformity surgery.

Authors:  Ali A Siddiqui; Lindsay M Andras; Kyle K Obana; Rajan Murgai; Kenneth D Illingworth; Vernon T Tolo; Michael Mariscal; Skorn Ponrartana; David L Skaggs
Journal:  Spine Deform       Date:  2020-08-11

6.  Awareness and attitudes amongst basic surgical trainees regarding radiation in orthopaedic trauma surgery.

Authors:  Fr Khan; Z Ul-Abadin; S Rauf; A Javed
Journal:  Biomed Imaging Interv J       Date:  2010-07-01

7.  Intra-operative fluoroscopic radiation exposure in orthopaedic trauma theatre.

Authors:  Mustafa S Rashid; Sheweidin Aziz; Syed Haydar; Simon S Fleming; Amit Datta
Journal:  Eur J Orthop Surg Traumatol       Date:  2017-08-10

8.  Radiation exposure from fluoroscopy during fixation of hip fracture and fracture of ankle: Effect of surgical experience.

Authors:  Rajesh Botchu; Kassetti Ravikumar
Journal:  Indian J Orthop       Date:  2008-10       Impact factor: 1.251

Review 9.  Radiation exposure of eyes, thyroid gland and hands in orthopaedic staff: a systematic review.

Authors:  Chandrasekharan Nair Kesavachandran; Frank Haamann; Albert Nienhaus
Journal:  Eur J Med Res       Date:  2012-10-30       Impact factor: 2.175

10.  Pulsation and Collimation During Fluoroscopy to Decrease Radiation: A Cadaver Study.

Authors:  Kazuta Yamashita; Kosaku Higashino; Hiroaki Hayashi; Fumio Hayashi; Yoshihiro Fukui; Koichi Sairyo
Journal:  JB JS Open Access       Date:  2017-12-19
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.