A New Slim Modiolar Electrode Array for Cochlear Implantation: A Radiological and Histological Study.

Matti Iso-Mustajärvi1, Hanna Matikka, Frank Risi, Sini Sipari, Teemu Koski, Tytti Willberg, Antti Lehtimäki, Jyrki Tervaniemi, Heikki Löppönen, Aarno Dietz.   

Abstract

HYPOTHESIS: To explore the results of a new slim modiolar electrode array (SMA) with respect to intracochlear placement and trauma evaluated by detailed radiologic imaging and histology.
BACKGROUND: Hearing and structure preservation is the goal of cochlear implantation for advanced hearing outcomes. Currently, this is most consistently achieved with thin lateral wall electrodes. Modiolar electrodes are located nearer the modiolus and may provide some electrophysiological advantages, but have a greater tendency for causing insertion trauma.
METHODS: The SMA was implanted in 20 fresh-frozen human temporal bones (TB). All TBs were scanned pre- and postoperatively with cone beam computed tomography. For atraumatic insertion, the round window approach was preferred. Scalar localization and trauma were analyzed by three-dimensional image fusion reconstructions of the pre- and postimplant scans. The TBs underwent histologic examination to validate the radiologic findings.
RESULTS: Insertion through the round window was performed in 19 TBs and through a cochleostomy in one TB. In one TB trauma in the form of scala translocation was identified radiologically and histologically. In the remaining TBs there was no insertion trauma. Adequate modiolar localization of the SMA was found in 19 of 20 TBs. The mean angular insertion depth was 400 degrees without correlation to cochlea size. There was no significant statistical difference between the radiological and histological measurements of electrode localization.
CONCLUSION: The SMA showed consistent and atraumatic insertion results in TBs. Pre- and postimplant cone beam computed tomography with image fusion was shown to be very accurate for the assessment of electrode position and insertion trauma.

Entities:  

Mesh:

Year:  2017        PMID: 28796083     DOI: 10.1097/MAO.0000000000001542

Source DB:  PubMed          Journal:  Otol Neurotol        ISSN: 1531-7129            Impact factor:   2.311


  8 in total

1.  Evaluation of a new slim lateral wall electrode for cochlear implantation: an imaging study in human temporal bones.

Authors:  Aarno Dietz; Matti Iso-Mustajärvi; Sini Sipari; Jyrki Tervaniemi; Dzemal Gazibegovic
Journal:  Eur Arch Otorhinolaryngol       Date:  2018-05-24       Impact factor: 2.503

2.  Imaging evaluation of electrode placement and effect on electrode discrimination on different cochlear implant electrode arrays.

Authors:  Ángel Ramos de Miguel; Andrea A Argudo; Silvia A Borkoski Barreiro; Juan Carlos Falcón González; Angel Ramos Macías
Journal:  Eur Arch Otorhinolaryngol       Date:  2018-04-02       Impact factor: 2.503

3.  A New Application of CBCT Image Fusion in Temporal Bone Studies.

Authors:  Matti Iso-Mustajärvi; Sini Sipari; Antti Lehtimäki; Jyrki Tervaniemi; Heikki Löppönen; Aarno Dietz
Journal:  J Int Adv Otol       Date:  2019-12       Impact factor: 1.017

Review 4.  Review on cochlear implant electrode array tip fold-over and scalar deviation.

Authors:  Anandhan Dhanasingh; Claude Jolly
Journal:  J Otol       Date:  2019-01-09

5.  Simpler and effective radiological evaluations for modiolar proximity of a slim modiolar cochlear implant electrode.

Authors:  Sang-Yeon Lee; Jin Hee Han; Marge Carandang; Yun Jung Bae; Byung Yoon Choi
Journal:  Sci Rep       Date:  2020-10-19       Impact factor: 4.379

6.  Radiological evaluation of a new straight electrode array compared to its precursors.

Authors:  Manuel Christoph Ketterer; A Aschendorff; S Arndt; I Speck; A K Rauch; R Beck; F Hassepass
Journal:  Eur Arch Otorhinolaryngol       Date:  2020-10-22       Impact factor: 2.503

7.  Effect of initial switch-on within 24 hours of cochlear implantation using slim modiolar electrodes.

Authors:  Woongsang Sunwoo; Hyoung Won Jeon; Byung Yoon Choi
Journal:  Sci Rep       Date:  2021-11-23       Impact factor: 4.379

8.  Effects of in vivo repositioning of slim modiolar electrodes on electrical thresholds and speech perception.

Authors:  Sang-Yeon Lee; Young Seok Kim; Hyung Dong Jo; Yoonjoong Kim; Marge Carandang; Gene Huh; Byung Yoon Choi
Journal:  Sci Rep       Date:  2021-07-23       Impact factor: 4.379