Literature DB >> 28762005

A Web-based searchable system to confirm magnetic resonance compatibility of implantable medical devices in Japan: a preliminary study.

Yasuhiro Fujiwara1, Hitoshi Fujioka2, Tomoko Watanabe2, Maiko Sekiguchi2, Ryuji Murakami3.   

Abstract

Confirmation of the magnetic resonance (MR) compatibility of implanted medical devices (IMDs) is mandatory before conducting magnetic resonance imaging (MRI) examinations. In Japan, few such confirmation methods are in use, and they are time-consuming. This study aimed to develop a Web-based searchable MR safety information system to confirm IMD compatibility and to evaluate the usefulness of the system. First, MR safety information for intravascular stents and stent grafts sold in Japan was gathered by interviewing 20 manufacturers. These IMDs were categorized based on the descriptions available on medical package inserts as: "MR Safe," "MR Conditional," "MR Unsafe," "Unknown," and "No Medical Package Insert Available". An MR safety information database for implants was created based on previously proposed item lists. Finally, a Web-based searchable system was developed using this database. A questionnaire was given to health-care personnel in Japan to evaluate the usefulness of this system. Seventy-nine datasets were collected using information provided by 12 manufacturers and by investigating the medical packaging of the IMDs. Although the datasets must be updated by collecting data from other manufacturers, this system facilitates the easy and rapid acquisition of MR safety information for IMDs, thereby improving the safety of MRI examinations.

Keywords:  MR compatibility; Magnetic resonance imaging (MRI); Management; Medical device; Safety

Mesh:

Year:  2017        PMID: 28762005     DOI: 10.1007/s12194-017-0409-2

Source DB:  PubMed          Journal:  Radiol Phys Technol        ISSN: 1865-0333


  10 in total

Review 1.  Pre-MRI procedure screening: recommendations and safety considerations for biomedical implants and devices.

Authors:  A M Sawyer-Glover; F G Shellock
Journal:  J Magn Reson Imaging       Date:  2000-07       Impact factor: 4.813

2.  [Collection of information regarding implants, internal and external metallic objects for MRI examinations].

Authors:  Masaki Kobayashi; Masato Kobayashi; Tatsuya Someno; Hiromi Uchiyama; Yuuki Ono
Journal:  Nihon Hoshasen Gijutsu Gakkai Zasshi       Date:  2011

3.  MR labeling information for implants and devices: explanation of terminology.

Authors:  Frank G Shellock; Terry O Woods; John V Crues
Journal:  Radiology       Date:  2009-10       Impact factor: 11.105

4.  ACR guidance document on MR safe practices: 2013.

Authors:  Emanuel Kanal; A James Barkovich; Charlotte Bell; James P Borgstede; William G Bradley; Jerry W Froelich; J Rod Gimbel; John W Gosbee; Ellisa Kuhni-Kaminski; Paul A Larson; James W Lester; John Nyenhuis; Daniel Joe Schaefer; Elizabeth A Sebek; Jeffrey Weinreb; Bruce L Wilkoff; Terry O Woods; Leonard Lucey; Dina Hernandez
Journal:  J Magn Reson Imaging       Date:  2013-01-23       Impact factor: 4.813

5.  [An investigative report concerning safety and management in the magnetic resonance environment: there are more accidents than expected].

Authors:  Tsukasa Doi; Yuya Yamatani; Tsuyoshi Ueyama; Shigeo Nishiki; Akio Ogura; Hideaki Kawamitsu; Toshio Tsuchihashi; Tomoyuki Okuaki; Tsuyoshi Matsuda; Masayuki Kumashiro
Journal:  Nihon Hoshasen Gijutsu Gakkai Zasshi       Date:  2011

6.  [Development of an magnetic resonance imaging safety management system for metallic biomedical products using an magnetic resonance compatibility database and inquiry-based patient records].

Authors:  Yasuhiro Fujiwara; Tomomi Kata; Shinichi Fujimoto; Takuya Yachida; Masayuki Kanamoto; Yousuke Nanbu; Kouichirou Seki; Nobuyuki Kosaka; Hirohiko Kimura; Toshiki Adachi
Journal:  Nihon Hoshasen Gijutsu Gakkai Zasshi       Date:  2014-12

7.  Response to Standardized MR Terminology and Reporting of Implants and Devices as Recommended by the American College of Radiology Subcommittee on MR Safety.

Authors:  Terry O Woods; Jana G Delfino; Mitchell J Shein
Journal:  Radiology       Date:  2015-11-23       Impact factor: 11.105

8.  Safety of magnetic resonance imaging in patients with cardiovascular devices: an American Heart Association scientific statement from the Committee on Diagnostic and Interventional Cardiac Catheterization, Council on Clinical Cardiology, and the Council on Cardiovascular Radiology and Intervention: endorsed by the American College of Cardiology Foundation, the North American Society for Cardiac Imaging, and the Society for Cardiovascular Magnetic Resonance.

Authors:  Glenn N Levine; Antoinette S Gomes; Andrew E Arai; David A Bluemke; Scott D Flamm; Emanuel Kanal; Warren J Manning; Edward T Martin; J Michael Smith; Norbert Wilke; Frank S Shellock
Journal:  Circulation       Date:  2007-11-19       Impact factor: 29.690

Review 9.  MR procedures: biologic effects, safety, and patient care.

Authors:  Frank G Shellock; John V Crues
Journal:  Radiology       Date:  2004-07-29       Impact factor: 11.105

Review 10.  MRI-conditional pacemakers: current perspectives.

Authors:  António M Ferreira; Francisco Costa; António Tralhão; Hugo Marques; Nuno Cardim; Pedro Adragão
Journal:  Med Devices (Auckl)       Date:  2014-05-07
  10 in total
  2 in total

1.  Torque property of titanium alloy cerebral aneurysm clips in a magnetic resonance scanner.

Authors:  Minghui Tang; Shingo Kawahira; Naoyuki Nomura; Toru Yamamoto
Journal:  J Mater Sci Mater Med       Date:  2019-12-14       Impact factor: 3.896

2.  Development of a Searchable System to Confirm MR Imaging Safety Information for Implantable Medical Devices.

Authors:  Yasuhiro Fujiwara; Hitoshi Fujioka; Maiko Sekiguchi; Haruna Tanaka; Tomoko Watanabe
Journal:  Magn Reson Med Sci       Date:  2019-02-19       Impact factor: 2.471

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.