Literature DB >> 28718314

Techniques of Force and Pressure Measurement in the Small Joints of the Wrist.

Michael J Schreck1, Meghan Kelly1, Colin D Canham1, John C Elfar1.   

Abstract

BACKGROUND: The alteration of forces across joints can result in instability and subsequent disability. Previous methods of force measurements such as pressure-sensitive films, load cells, and pressure-sensing transducers have been utilized to estimate biomechanical forces across joints and more recent studies have utilized a nondestructive method that allows for assessment of joint forces under ligamentous restraints.
METHODS: A comprehensive review of the literature was performed to explore the numerous biomechanical methods utilized to estimate intra-articular forces.
RESULTS: Methods of biomechanical force measurements in joints are reviewed.
CONCLUSIONS: Methods such as pressure-sensitive films, load cells, and pressure-sensing transducers require significant intra-articular disruption and thus may result in inaccurate measurements, especially in small joints such as those within the wrist and hand. Non-destructive methods of joint force measurements either utilizing distraction-based joint reaction force methods or finite element analysis may offer a more accurate assessment; however, given their recent inception, further studies are needed to improve and validate their use.

Entities:  

Keywords:  DRUJ; biomechanics; joint forces; pressure transducers; pressure-sensing films

Mesh:

Year:  2017        PMID: 28718314      PMCID: PMC5755860          DOI: 10.1177/1558944716688529

Source DB:  PubMed          Journal:  Hand (N Y)        ISSN: 1558-9447


  34 in total

1.  The dorsopalmar stability of the distal radioulnar joint.

Authors:  P R Stuart; R A Berger; R L Linscheid; K N An
Journal:  J Hand Surg Am       Date:  2000-07       Impact factor: 2.230

2.  The distal radioulnar joint as a load-bearing mechanism--a biomechanical study.

Authors:  Hassan Shaaban; Giannis Giakas; Mike Bolton; Robert Williams; Louis R Scheker; Vivien C Lees
Journal:  J Hand Surg Am       Date:  2004-01       Impact factor: 2.230

3.  Measuring contact area, force, and pressure for bioengineering applications: using Fuji Film and TekScan systems.

Authors:  Kent N Bachus; Alyssa L DeMarco; Kyle T Judd; Daniel S Horwitz; Darrel S Brodke
Journal:  Med Eng Phys       Date:  2005-09-21       Impact factor: 2.242

4.  Ulnar-shortening effect on distal radioulnar joint pressure: a biomechanical study.

Authors:  Masao Nishiwaki; Toshiyasu Nakamura; Takeo Nagura; Yoshiaki Toyama; Hiroyasu Ikegami
Journal:  J Hand Surg Am       Date:  2008-02       Impact factor: 2.230

5.  Pressure distribution in the distal radioulnar joint.

Authors:  S Ishii; A K Palmer; F W Werner; W H Short; M D Fortino
Journal:  J Hand Surg Am       Date:  1998-09       Impact factor: 2.230

6.  Effect on force transmission across the carpus in procedures used to treat Kienböck's disease.

Authors:  E Horii; M Garcia-Elias; A T Bishop; W P Cooney; R L Linscheid; E Y Chao
Journal:  J Hand Surg Am       Date:  1990-05       Impact factor: 2.230

7.  The influence of wire positioning upon the initial stability of scaphoid fractures fixed using Kirschner wires A finite element study.

Authors:  F Ezquerro; S Jiménez; A Pérez; M Prado; G de Diego; A Simón
Journal:  Med Eng Phys       Date:  2006-10-25       Impact factor: 2.242

8.  Mathematical modelling for the comparison of plate and intramedullary osteosynthesis stability in intraarticular distal radius fractures.

Authors:  M Vlcek; I Landor; Z Horak; V Musil; A Sosna; D Jonas
Journal:  Bratisl Lek Listy       Date:  2014       Impact factor: 1.278

9.  A comparison of early and late reconstruction of malunited fractures of the distal end of the radius.

Authors:  J B Jupiter; D Ring
Journal:  J Bone Joint Surg Am       Date:  1996-05       Impact factor: 5.284

10.  Distal Radioulnar Joint Reaction Force Following Ulnar Shortening: Diaphyseal Osteotomy Versus Wafer Resection.

Authors:  Colin D Canham; Michael J Schreck; Noorullah Maqsoodi; Susan Messing; Mark Olles; John C Elfar
Journal:  J Hand Surg Am       Date:  2015-10-06       Impact factor: 2.230

View more
  1 in total

1.  Biomechanical evaluation of axial-loading simulated experiment in wrist fractures: a finite element analysis.

Authors:  You-Liang Fan; Hai-Yun Xu; Ming-Yang Xia; Wen Zhang; Hui-Long Wen; Li-Bo Gao; Yan-Hui Pei
Journal:  J Int Med Res       Date:  2020-10       Impact factor: 1.671

  1 in total