Measuring contact area, force, and pressure for bioengineering applications: using Fuji Film and TekScan systems.

Kent N Bachus1, Alyssa L DeMarco, Kyle T Judd, Daniel S Horwitz, Darrel S Brodke.   

Abstract

The goal of this study was to compare the TekScan I-Scan Pressure Measurement System with two methods of analysis involving the Fuji Film Prescale Pressure Measuring System in estimating area, force and pressure. Fuji Film and TekScan sensors were alternately placed between a cylindrical peg and a finely ground steel base plate, and compressed with known forces. All Fuji stains were digitally scanned and analyzed. The Erase method of Fuji Film analysis consisted of manually removing portions of the image judged by the user to be outside the perimeter of the stain. The second method of Fuji Film analysis, termed the Threshold method, used the threshold tool to analyze only those pixels that were stained from loading. The TekScan system utilized special matrix-based sensors interfaced with a Windows compatible desktop computer that was equipped with specialized data acquisition hardware and analysis software. The data from this study did not support the hypothesis that all three methods would have accuracies within +/-5% of a known value, when estimating area, force and pressure. Specifically, the TekScan system was found to be more accurate than either of the Fuji Film methods when estimating area and pressure.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 16181797     DOI: 10.1016/j.medengphy.2005.07.022

Source DB:  PubMed          Journal:  Med Eng Phys        ISSN: 1350-4533            Impact factor:   2.242


  25 in total

1.  PCL to graft impingement pressure after anatomical or non-anatomical single-bundle ACL reconstruction.

Authors:  Takanori Iriuchishima; Goro Tajima; Sheila J M Ingham; Kenji Shirakura; Freddie H Fu
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2011-09-21       Impact factor: 4.342

2.  Effects of initial graft tension on the tibiofemoral compressive forces and joint position after anterior cruciate ligament reconstruction.

Authors:  Mark F Brady; Michael P Bradley; Braden C Fleming; Paul D Fadale; Michael J Hulstyn; Rahul Banerjee
Journal:  Am J Sports Med       Date:  2007-01-11       Impact factor: 6.202

Review 3.  Techniques of Force and Pressure Measurement in the Small Joints of the Wrist.

Authors:  Michael J Schreck; Meghan Kelly; Colin D Canham; John C Elfar
Journal:  Hand (N Y)       Date:  2017-02-06

4.  Intercondylar roof impingement pressure after anterior cruciate ligament reconstruction in a porcine model.

Authors:  Takanori Iriuchishima; Goro Tajima; Sheila J M Ingham; Wei Shen; Takashi Horaguchi; Akiyoshi Saito; Patrick Smolinski; Freddie H Fu
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2008-12-17       Impact factor: 4.342

5.  Effects of implant rotational malposition on contact surface area after implantation of the augmented glenoid baseplate in the setting of glenoid bone loss.

Authors:  Aimee Bobko; Gary Edwards; Jose Rodriguez; Taylor Southworth; Adam Miller; Dmitriy Peresada; Leonard Onsen; Benjamin Goldberg
Journal:  Int Orthop       Date:  2021-04-20       Impact factor: 3.075

6.  Tibiofemoral compression force differences using laxity- and force-based initial graft tensioning techniques in the anterior cruciate ligament-reconstructed cadaveric knee.

Authors:  Braden C Fleming; Mark F Brady; Michael P Bradley; Rahul Banerjee; Michael J Hulstyn; Paul D Fadale
Journal:  Arthroscopy       Date:  2008-06-30       Impact factor: 4.772

7.  Increased patellofemoral pressure after TKA: an in vitro study.

Authors:  Ulf G Leichtle; Markus Wünschel; Carmen I Leichtle; Otto Müller; Philipp Kohler; Nikolaus Wülker; Andrea Lorenz
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2013-01-18       Impact factor: 4.342

8.  Different effects of the lateral meniscus complete radial tear on the load distribution and transmission functions depending on the tear site.

Authors:  Tomoki Ohori; Tatsuo Mae; Konsei Shino; Hiromichi Fujie; Takehito Hirose; Yuta Tachibana; Hideki Yoshikawa; Ken Nakata
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2020-03-10       Impact factor: 4.342

9.  A nondestructive, reproducible method of measuring joint reaction force at the distal radioulnar joint.

Authors:  Colin D Canham; Michael J Schreck; Noorullah Maqsoodi; Madison Doolittle; Mark Olles; John C Elfar
Journal:  J Hand Surg Am       Date:  2015-04-16       Impact factor: 2.230

10.  Novel metallic implantation technique for osteochondral defects of the medial talar dome. A cadaver study.

Authors:  Christiaan J A van Bergen; Maartje Zengerink; Leendert Blankevoort; Maayke N van Sterkenburg; Jakob van Oldenrijk; C Niek van Dijk
Journal:  Acta Orthop       Date:  2010-08       Impact factor: 3.717