You-Liang Fan1, Hai-Yun Xu1, Ming-Yang Xia1, Wen Zhang2, Hui-Long Wen1, Li-Bo Gao1, Yan-Hui Pei1.
Abstract
OBJECTIVE: To assess the biomechanical properties that influence wrist fracture, so as to provide the theoretical basis for simulation experiments to aid the optimal design of wrist protectors.Entities:
Keywords: Wrist fracture; biomechanical evaluation; finite element analysis; wrist protector
Mesh:
Year: 2020 PMID: 33135534 PMCID: PMC7780565 DOI: 10.1177/0300060520966884
Source DB: PubMed Journal: J Int Med Res ISSN: 0300-0605 Impact factor: 1.671
Figure 1.(a) The axial-loading experiment on cadaveric wrist specimens. (b) The establishment of four static strain test units.
Comparison of the peak stress and declines between the experimental and control groups.
| Peak stress of the control group, MPa | Peak stress of the experimental group, MPa | Mean percentage decline in peak stress | |
|---|---|---|---|
| Radial distal palmar unit | 36.6 | 20.2 | 44.8%* |
| Ulnar distal palmar unit | 37.9 | 24.3 | 35.9%* |
| Radial distal dorsal unit | 9.4 | 5.7 | 39.4%* |
| Ulnar distal dorsal unit | 13.4 | 4.8 | 64.2%* |
| Radial proximal palmar unit | 58.5 | 30.1 | 48.5%* |
| Ulnar proximal palmar unit | 37.4 | 24.9 | 33.4%* |
| Radial proximal dorsal unit | 10.5 | 10.3 | 1.9% |
| Ulnar proximal dorsal unit | 15.3 | 13.8 | 9.8% |
Data presented as mean.
*Significant between-group difference (P < 0.05); paired Student’s t-test.
Figure 2.Comparison of the load and stress of each unit in the experimental and control groups. Data presented as mean. The colour version of this figure is available at: http://imr.sagepub.com.
Figure 3.Comparison of the load and stress curves for each unit between the experimental and control groups. Data presented as mean. The colour version of this figure is available at: http://imr.sagepub.com.
The number of nodes, unit types and unit numbers of the finite element model of a normal human wrist joint.
| Bone | Cancellous bone | Soft tissue | Rigid ground | Soft brace | Rigid brace | |
|---|---|---|---|---|---|---|
| Unit number | 136 897 | 9166 | 228 893 | 2500 | 12 048 | 3984 |
| Nodes | 228 808 | 20499 | 356 621 | 2603 | 4196 | 2090 |
| Unit type | C3D10M | C3D10M | C3D10M | S4R | C3D10M | S3R |
Figure 4.Stress distribution patterns in the 3-dimensional finite element models of the control and experimental groups at the late stage of the experiments: (a) the stress colour pattern of the control group that did not have the buffer of a wrist protector was deeper than the experimental group in the radioulnar distal palmar, radioulnar proximal palmar and radioulnar distal dorsal units; (b) the overall stress colour pattern of the experimental group that had a wrist protector was lighter than the control group. The colour version of this figure is available at: http://imr.sagepub.com.