Literature DB >> 17067844

The influence of wire positioning upon the initial stability of scaphoid fractures fixed using Kirschner wires A finite element study.

F Ezquerro1, S Jiménez, A Pérez, M Prado, G de Diego, A Simón.   

Abstract

A finite element model of the carpal scaphoid and its joints was developed to study how wire positioning affects the initial stability of the fixation of scaphoid waist fractures using Kirschner wires. A transverse fracture of the scaphoid waist was simulated along with its fixation using five different two-wire configurations. The resulting models were subjected to a load simulating a 200N force passing through the wrist. Friction between bony fragments was taken into account; as the friction coefficient of cancellous bone is unknown, three different values were analysed. For each of these friction coefficient values, the smallest transverse interfragmentary displacements, and consequently maximum initial stability, were obtained for the model that simulated the maximum gap between wires in the plane of fracture. Results also show that for a similar gap in the plane of fracture, more stable fixation can be achieved when wires cross each other not only in the frontal plane of the hand, but also perpendicularly to it.

Entities:  

Mesh:

Year:  2006        PMID: 17067844     DOI: 10.1016/j.medengphy.2006.08.005

Source DB:  PubMed          Journal:  Med Eng Phys        ISSN: 1350-4533            Impact factor:   2.242


  8 in total

1.  High speed insertion of bone fracture fixation pins: a finite element penetration model with experimental comparisons.

Authors:  Matthew P Prygoski; Timotius Pasang; Steven R Schmid; Antony J Lozier
Journal:  J Mater Sci Mater Med       Date:  2011-11-01       Impact factor: 3.896

Review 2.  Techniques of Force and Pressure Measurement in the Small Joints of the Wrist.

Authors:  Michael J Schreck; Meghan Kelly; Colin D Canham; John C Elfar
Journal:  Hand (N Y)       Date:  2017-02-06

3.  Establishing a central zone in scaphoid surgery: a computational approach.

Authors:  Yang Guo; Guang Lei Tian; Shanlin Chen; Carla Tapia
Journal:  Int Orthop       Date:  2013-09-10       Impact factor: 3.075

4.  Finite element analysis of the wrist in stroke patients: the effects of hand grip.

Authors:  Muhammad Hanif Ramlee; Gan Kok Beng; Nazri Bajuri; Mohammed Rafiq Abdul Kadir
Journal:  Med Biol Eng Comput       Date:  2017-12-05       Impact factor: 2.602

5.  Validation of radiocarpal joint contact models based on images from a clinical MRI scanner.

Authors:  Joshua E Johnson; Terence E McIff; Phil Lee; E Bruce Toby; Kenneth J Fischer
Journal:  Comput Methods Biomech Biomed Engin       Date:  2012-05-25       Impact factor: 1.763

6.  Four-Corner Arthrodesis: Description of Surgical Technique Using Headless Retrograde Crossed Screws.

Authors:  João Mamede; Sandro Castro Adeodato; Rafael Aquino Leal
Journal:  Hand (N Y)       Date:  2017-04-05

7.  Radiographic Parameters to Predict Union After Volar Percutaneous Fixation of Herbert Type B1 and B2 Scaphoid Fractures.

Authors:  Mostafa Mahmoud; Mohamed Hegazy; Sherif Ahmed Khaled; Nasef Mohamed Nasef Abdelatif; Walid Osman; John C Elfar
Journal:  J Hand Surg Am       Date:  2016-02       Impact factor: 2.230

8.  Absorbable scaphoid screw development: a comparative study on biomechanics.

Authors:  Yi Wang; Muguo Song; Yongqing Xu; Xiaoqing He; YueLiang Zhu
Journal:  Ther Clin Risk Manag       Date:  2016-04-22       Impact factor: 2.423

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.