Literature DB >> 28717932

A W-Geometry Ortho-TOF MS with High Resolution and Up to 100% Duty Cycle for MS/MS.

Igor V Chernushevich1, Samuel I Merenbloom2, Suya Liu3, Nic Bloomfield3.   

Abstract

Orthogonal injection time-of-flight (orthoTOF) mass spectrometry (MS) is the most prevalent form of TOFMS, owing to its greater control over incoming ion energy, the ability to correct for aberrations in incoming ion velocity and position, and its ability to provide an entire mass spectrum within a single scan. However, the duty cycle of orthoTOFMS is low compared with scanning analyzers, which can have 100% duty cycle when measuring a single type of ion. Typical duty cycles for orthoTOFMS range from 1% to 30%, depending on instrument geometry. Generally, as instrument resolution increases, duty cycle decreases. Additionally, the greatest duty cycle is achieved for the highest m/z ion recorded in the spectrum, and decreases for all other ions as a function of m/z. In a prior publication [Loboda, A.V.; Chernushevich, I.V. J. Am. Soc. Mass Spectrom. 20, 1342-1348 (20)], a novel trapping/release method for restoring the duty cycle of a V-geometry orthoTOFMS to near 100% (referred to as "Zeno pulsing") was presented. Here, we apply that method to a W-TOF geometry analyzer with analog detection. Across a m/z range of 100-2000, sensitivity gains of ~5-20 are observed, for total ion currents approaching ~107 ions·s-1. Zeno pulsing, or similar strategies for restoring duty cycle, will continue to be important as instrument resolution in orthoTOFMS is increased through the use of ion mirrors. Graphical Abstract ᅟ.

Keywords:  Collision cell; Duty cycle; Ion trapping; Mass resolution; Quadrupole; Time-of-flight mass spectrometry; Zeno; orthoTOF

Year:  2017        PMID: 28717932     DOI: 10.1007/s13361-017-1742-8

Source DB:  PubMed          Journal:  J Am Soc Mass Spectrom        ISSN: 1044-0305            Impact factor:   3.109


  13 in total

Review 1.  Orthogonal acceleration time-of-flight mass spectrometry.

Authors:  M Guilhaus; D Selby; V Mlynski
Journal:  Mass Spectrom Rev       Date:  2000 Mar-Apr       Impact factor: 10.946

Review 2.  An introduction to quadrupole-time-of-flight mass spectrometry.

Authors:  I V Chernushevich; A V Loboda; B A Thomson
Journal:  J Mass Spectrom       Date:  2001-08       Impact factor: 1.982

3.  Multi-turn time-of-flight mass spectrometers with electrostatic sectors.

Authors:  Michisato Toyoda; Daisuke Okumura; Morio Ishihara; Itsuo Katakuse
Journal:  J Mass Spectrom       Date:  2003-11       Impact factor: 1.982

Review 4.  Biomolecule analysis by ion mobility spectrometry.

Authors:  Brian C Bohrer; Samuel I Merenbloom; Stormy L Koeniger; Amy E Hilderbrand; David E Clemmer
Journal:  Annu Rev Anal Chem (Palo Alto Calif)       Date:  2008       Impact factor: 10.745

5.  Duty cycle enhancement of an orthogonal acceleration TOF mass spectrometer using an axially-resonant excitation linear ion trap.

Authors:  Yuichiro Hashimoto; Hideki Hasegawa; Hiroyuki Satake; Takashi Baba; Izumi Waki
Journal:  J Am Soc Mass Spectrom       Date:  2006-08-22       Impact factor: 3.109

6.  Improvement of the duty cycle of an orthogonal acceleration time-of-flight mass spectrometer using ion gates.

Authors:  A G Brenton; T Krastev; D J Rousell; M A Kennedy; A S Craze; C M Williams
Journal:  Rapid Commun Mass Spectrom       Date:  2007       Impact factor: 2.419

7.  A novel ion trap that enables high duty cycle and wide m/z range on an orthogonal injection TOF mass spectrometer.

Authors:  Alexander V Loboda; Igor V Chernushevich
Journal:  J Am Soc Mass Spectrom       Date:  2009-03-31       Impact factor: 3.109

8.  Peer Reviewed: Orthogonal-Injection TOFMS for Analyzing Biomolecules.

Authors:  I V Chernushevich; W Ens; K G Standing
Journal:  Anal Chem       Date:  1999-07       Impact factor: 6.986

Review 9.  In pursuit of resolution in time-of-flight mass spectrometry: A historical perspective.

Authors:  Anna Radionova; Igor Filippov; Peter J Derrick
Journal:  Mass Spectrom Rev       Date:  2015-05-12       Impact factor: 10.946

10.  Reflecting time-of-flight mass spectrometer with an electrospray ion source and orthogonal extraction.

Authors:  A N Verentchikov; W Ens; K G Standing
Journal:  Anal Chem       Date:  1994-01-01       Impact factor: 6.986

View more
  3 in total

1.  A W-Geometry Ortho-TOF MS with High Resolution and Up to 100% Duty Cycle for MS/MS.

Authors:  Igor V Chernushevich; Samuel I Merenbloom; Suya Liu; Nic Bloomfield
Journal:  J Am Soc Mass Spectrom       Date:  2017-07-17       Impact factor: 3.109

Review 2.  High-Resolution Native Mass Spectrometry.

Authors:  Sem Tamara; Maurits A den Boer; Albert J R Heck
Journal:  Chem Rev       Date:  2021-08-20       Impact factor: 72.087

3.  Quantitative structural multiclass lipidomics using differential mobility: electron impact excitation of ions from organics (EIEIO) mass spectrometry.

Authors:  Takashi Baba; J Larry Campbell; J C Yves Le Blanc; Paul R S Baker; Kazutaka Ikeda
Journal:  J Lipid Res       Date:  2018-03-14       Impact factor: 5.922

  3 in total