Literature DB >> 17705255

Improvement of the duty cycle of an orthogonal acceleration time-of-flight mass spectrometer using ion gates.

A G Brenton1, T Krastev, D J Rousell, M A Kennedy, A S Craze, C M Williams.   

Abstract

A method to control the duty cycle of a time-of-flight mass spectrometer is described. The method relies on one or more ion gates placed in the beam path that have the function to transmit or stop the beam. These ion gates can switch from the open state to the closed state in tens of nanoseconds and effectively select portions of the mass range. The method is useful in circumstances where recording the complete mass spectrum is not an essential requirement, for example, in the analysis of known compounds where sensitivity and speed of operation are more important. It will be of benefit for applications in separation sciences with techniques involving fast chromatographic separations, where hundreds of mass spectra may be required per second. In such circumstances analytical identification may require only a limited number of masses (or mass regions) to be continuously monitored. Improvement of the duty cycle is particularly important for orthogonal-acceleration time-of-flight (oa-TOF) mass spectrometry instruments whose performance suffers from a low duty cycle. The duty cycle is not a constant for an instrument design but is a mass-dependent function and is least for smaller masses. The method described here is capable of raising the duty cycle to 100%. A theory is developed for one or more ion gate arrangements, for both linear- and reflectron-TOF systems. For a two-gate system the relationship between the positions of the first and second gates is described by a '2/3 rule'. Experimental results are shown for one-gate and two-gate operation, both in linear and in reflectron modes of operation, on an oa-TOF system built in-house. Copyright (c) 2007 John Wiley & Sons, Ltd.

Mesh:

Substances:

Year:  2007        PMID: 17705255     DOI: 10.1002/rcm.3186

Source DB:  PubMed          Journal:  Rapid Commun Mass Spectrom        ISSN: 0951-4198            Impact factor:   2.419


  7 in total

1.  A novel ion trap that enables high duty cycle and wide m/z range on an orthogonal injection TOF mass spectrometer.

Authors:  Alexander V Loboda; Igor V Chernushevich
Journal:  J Am Soc Mass Spectrom       Date:  2009-03-31       Impact factor: 3.109

2.  Interleaved Distance-of-Flight Mass Spectrometry: A Simple Method to Improve the Instrument Duty Factor.

Authors:  Alexander Gundlach-Graham; Elise A Dennis; Steven J Ray; Christie G Enke; Charles J Barinaga; David W Koppenaal; Gary M Hieftje
Journal:  J Am Soc Mass Spectrom       Date:  2013-08-28       Impact factor: 3.109

3.  A W-Geometry Ortho-TOF MS with High Resolution and Up to 100% Duty Cycle for MS/MS.

Authors:  Igor V Chernushevich; Samuel I Merenbloom; Suya Liu; Nic Bloomfield
Journal:  J Am Soc Mass Spectrom       Date:  2017-07-17       Impact factor: 3.109

4.  Ion mobility tandem mass spectrometry enhances performance of bottom-up proteomics.

Authors:  Dominic Helm; Johannes P C Vissers; Christopher J Hughes; Hannes Hahne; Benjamin Ruprecht; Fiona Pachl; Arkadiusz Grzyb; Keith Richardson; Jason Wildgoose; Stefan K Maier; Harald Marx; Mathias Wilhelm; Isabelle Becher; Simone Lemeer; Marcus Bantscheff; James I Langridge; Bernhard Kuster
Journal:  Mol Cell Proteomics       Date:  2014-08-08       Impact factor: 5.911

5.  Distance-of-Flight Mass Spectrometry: What, Why, and How?

Authors:  Elise A Dennis; Alexander W Gundlach-Graham; Steven J Ray; Christie G Enke; Gary M Hieftje
Journal:  J Am Soc Mass Spectrom       Date:  2016-08-25       Impact factor: 3.109

6.  From the discovery of field ionization to field desorption and liquid injection field desorption/ionization-mass spectrometry-A journey from principles and applications to a glimpse into the future.

Authors:  Jürgen H Gross
Journal:  Eur J Mass Spectrom (Chichester)       Date:  2020-06-30       Impact factor: 1.067

Review 7.  Towards Higher Sensitivity of Mass Spectrometry: A Perspective From the Mass Analyzers.

Authors:  Chang Li; Shiying Chu; Siyuan Tan; Xinchi Yin; You Jiang; Xinhua Dai; Xiaoyun Gong; Xiang Fang; Di Tian
Journal:  Front Chem       Date:  2021-12-21       Impact factor: 5.221

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.