Literature DB >> 19394860

A novel ion trap that enables high duty cycle and wide m/z range on an orthogonal injection TOF mass spectrometer.

Alexander V Loboda1, Igor V Chernushevich.   

Abstract

Although TOF analyzers with orthogonal ion injection provide the whole spectrum without scanning, their duty cycle is low compared with scanning analyzers in single ion monitoring mode. Typical duty cycle is in the range of 5% to 30% depending on the instrument geometry and ion m/z value. We present here a novel trapping/releasing setup, which offers the duty cycle near 100% over a wide range. Operation in the mass range from m/z 120 to almost 2000 is demonstrated. Ions are trapped in a short linear ion trap at the end of the collision cell in an axial pseudopotential well created by additional rf ("AC") voltage applied to all four rods of the trap with the same amplitude and phase. The pseudopotential created by AC field is mass dependent, and by ramping down the AC voltage, ions can be released from the trap sequentially from high m/z to low, while all ions are gaining the same kinetic energy. Upon entering the TOF accelerator, ions with lower m/z catch up with heavier ions, and the AC ramp parameters can be selected to make all ions meet in the center of the TOF extraction region, resulting in sensitivity gains from 3 to 14 without loss of mass accuracy or resolution.

Year:  2009        PMID: 19394860     DOI: 10.1016/j.jasms.2009.03.018

Source DB:  PubMed          Journal:  J Am Soc Mass Spectrom        ISSN: 1044-0305            Impact factor:   3.109


  7 in total

Review 1.  Orthogonal acceleration time-of-flight mass spectrometry.

Authors:  M Guilhaus; D Selby; V Mlynski
Journal:  Mass Spectrom Rev       Date:  2000 Mar-Apr       Impact factor: 10.946

Review 2.  An introduction to quadrupole-time-of-flight mass spectrometry.

Authors:  I V Chernushevich; A V Loboda; B A Thomson
Journal:  J Mass Spectrom       Date:  2001-08       Impact factor: 1.982

3.  Duty cycle enhancement of an orthogonal acceleration TOF mass spectrometer using an axially-resonant excitation linear ion trap.

Authors:  Yuichiro Hashimoto; Hideki Hasegawa; Hiroyuki Satake; Takashi Baba; Izumi Waki
Journal:  J Am Soc Mass Spectrom       Date:  2006-08-22       Impact factor: 3.109

4.  Improvement of the duty cycle of an orthogonal acceleration time-of-flight mass spectrometer using ion gates.

Authors:  A G Brenton; T Krastev; D J Rousell; M A Kennedy; A S Craze; C M Williams
Journal:  Rapid Commun Mass Spectrom       Date:  2007       Impact factor: 2.419

5.  Peer Reviewed: Orthogonal-Injection TOFMS for Analyzing Biomolecules.

Authors:  I V Chernushevich; W Ens; K G Standing
Journal:  Anal Chem       Date:  1999-07       Impact factor: 6.986

6.  High sensitivity collisionally-activated decomposition tandem mass spectrometry on a novel quadrupole/orthogonal-acceleration time-of-flight mass spectrometer.

Authors:  H R Morris; T Paxton; A Dell; J Langhorne; M Berg; R S Bordoli; J Hoyes; R H Bateman
Journal:  Rapid Commun Mass Spectrom       Date:  1996       Impact factor: 2.419

7.  Reflecting time-of-flight mass spectrometer with an electrospray ion source and orthogonal extraction.

Authors:  A N Verentchikov; W Ens; K G Standing
Journal:  Anal Chem       Date:  1994-01-01       Impact factor: 6.986

  7 in total
  4 in total

1.  Interleaved Distance-of-Flight Mass Spectrometry: A Simple Method to Improve the Instrument Duty Factor.

Authors:  Alexander Gundlach-Graham; Elise A Dennis; Steven J Ray; Christie G Enke; Charles J Barinaga; David W Koppenaal; Gary M Hieftje
Journal:  J Am Soc Mass Spectrom       Date:  2013-08-28       Impact factor: 3.109

2.  A W-Geometry Ortho-TOF MS with High Resolution and Up to 100% Duty Cycle for MS/MS.

Authors:  Igor V Chernushevich; Samuel I Merenbloom; Suya Liu; Nic Bloomfield
Journal:  J Am Soc Mass Spectrom       Date:  2017-07-17       Impact factor: 3.109

3.  Controlled ion ejection from an external trap for extended m/z range in FT-ICR mass spectrometry.

Authors:  Nathan K Kaiser; Joshua J Savory; Christopher L Hendrickson
Journal:  J Am Soc Mass Spectrom       Date:  2014-04-02       Impact factor: 3.109

Review 4.  Towards Higher Sensitivity of Mass Spectrometry: A Perspective From the Mass Analyzers.

Authors:  Chang Li; Shiying Chu; Siyuan Tan; Xinchi Yin; You Jiang; Xinhua Dai; Xiaoyun Gong; Xiang Fang; Di Tian
Journal:  Front Chem       Date:  2021-12-21       Impact factor: 5.221

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.