Literature DB >> 28708724

Impact of SSF on Diagnostic Performance of Coronary Computed Tomography Angiography Within 1 Heart Beat in Patients With High Heart Rate Using a 256-Row Detector Computed Tomography.

Junfu Liang, Hui Wang, Lei Xu, Li Dong, Zhanming Fan, Rui Wang, Zhonghua Sun.   

Abstract

OBJECTIVE: The aim of this study was to investigate the impact of a motion-correction algorithm on diagnostic accuracy of coronary computed tomography angiography (CCTA) within 1 heart beat in patients with high heart rate (HR) using a 256-row detector CT.
METHOD: Sixty-four consecutive patients with known or suspected coronary artery disease (symptomatic) and with HR of 75 beats per minute or greater (mean [SD] HR, 82.6 [7.3] beats per minute) undergoing CCTA and invasive coronary angiography within 4 weeks were prospectively enrolled. Coronary computed tomography angiography was performed with a 256-row detector CT (Revolution CT, GE Healthcare) using prospectively electrocardiography-triggered volume scan in 1 heart beat. All images were reconstructed using standard (STD) algorithm and a motion-correction algorithm reconstruction (Snapshot Freeze SSF; GE Healthcare) technique. The image quality of coronary artery segments was evaluated by 2 experienced radiologists using a 4-point scale based on the 18-segment model. Diagnostic accuracy was compared between STD and SSF for significant lumen stenosis (≥50%) of each segment with invasive coronary angiography as the reference standard for determining significant stenosis.
RESULTS: The diagnostic sensitivity, specificity, positive predictive value, and negative predictive value with STD and SSF were 93.7%, 85.1%, 50.2%, and 98.8% versus 91.9%, 95.8%, 77.9%, and 98.7% on per-segment assessment; 98.7%, 74.0%, 62.9%, and 99.2% versus 96.2%, 94.4%, 77.9%, and 98.7% on per-artery assessment; and 100%, 14.3%, 70.5%, and 100% versus 100%, 85.7%, 93.5%, and 100% on per-patient assessment, respectively. There was a significant difference in accuracy between STD and SFF on per-patient level 71.9% versus 95.3%, on per-artery level 81.6% versus 94.9%, and per-segment level 86.3% versus 95.3%, respectively. The area under receiver operating characteristics curve analysis also showed a significant improvement on diagnostic performance with the SSF technique versus with the STD algorithm on per-patient level (P < 0.001), with corresponding area under the curve being 0.91 (95% confidence interval, 0.79-1.00) and 0.60 (95% confidence interval, 0.44-0.75). The mean effective dose was 2.0 mSv.
CONCLUSIONS: Coronary computed tomography angiography can be performed in patients with high HR within 1 heart beat yielding low radiation dose. The use of SSF technique reconstruction for 1 heart beat CCTA achieves significant improvements in image quality and diagnostic value.

Entities:  

Mesh:

Substances:

Year:  2018        PMID: 28708724     DOI: 10.1097/RCT.0000000000000641

Source DB:  PubMed          Journal:  J Comput Assist Tomogr        ISSN: 0363-8715            Impact factor:   1.826


  8 in total

1.  Second-generation motion correction algorithm improves diagnostic accuracy of single-beat coronary CT angiography in patients with increased heart rate.

Authors:  Junfu Liang; Ying Sun; Ziqing Ye; Yanchun Sun; Lei Xu; Zhen Zhou; Brian Thomsen; Jianying Li; Zhonghua Sun; Zhanming Fan
Journal:  Eur Radiol       Date:  2019-01-07       Impact factor: 5.315

2.  Relationship between heart rate and optimal reconstruction phase in coronary CT angiography performed on a 256-slice multidetector CT.

Authors:  Ching-Ching Yang; Wei-Yip Law; Kun-Mu Lu; Tung-Hsin Wu
Journal:  Br J Radiol       Date:  2019-07-29       Impact factor: 3.039

3.  Personalized 3D printed coronary models in coronary stenting.

Authors:  Zhonghua Sun; Shirley Jansen
Journal:  Quant Imaging Med Surg       Date:  2019-08

4.  Influence of Heart Rate and Innovative Motion-Correction Algorithm on Coronary Artery Image Quality and Measurement Accuracy Using 256-Detector Row Computed Tomography Scanner: Phantom Study.

Authors:  Jeong Bin Park; Yeon Joo Jeong; Geewon Lee; Nam Kyung Lee; Jin You Kim; Ji Won Lee
Journal:  Korean J Radiol       Date:  2018-12-27       Impact factor: 3.500

Review 5.  Clinical Applications of Wide-Detector CT Scanners for Cardiothoracic Imaging: An Update.

Authors:  Eun Ju Kang
Journal:  Korean J Radiol       Date:  2019-12       Impact factor: 3.500

6.  Radiation dose and image quality of CT coronary angiography in patients with high heart rate or irregular heart rhythm using a 16-cm wide detector CT scanner.

Authors:  Marian Ondrejkovic; Dusan Salat; Daniel Cambal; Andrej Klepanec
Journal:  Medicine (Baltimore)       Date:  2022-09-16       Impact factor: 1.817

7.  Intraindividual evaluation of effects of image filter function on image quality in coronary computed tomography angiography.

Authors:  Liang Jin; Pan Gao; Kun Wang; Jianying Li; Ming Li
Journal:  Front Cardiovasc Med       Date:  2022-09-15

Review 8.  Diagnostic accuracy of prospectively gated, 128-slice or greater CTCA at high heart rates: a systematic review and meta-analysis.

Authors:  Gordon T W Mander; Karen Dobeli; Caitlin Steffensen; Zachary Munn
Journal:  J Med Radiat Sci       Date:  2021-07-07
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.