Literature DB >> 28680544

Stress analysis of mandibular implant overdenture with locator and bar/clip attachment: Comparative study with differences in the denture base length.

Jin Suk Yoo1, Kung-Rock Kwon2, Kwantae Noh2, Hyeonjong Lee2, Janghyun Paek2.   

Abstract

PURPOSE: The design of the attachment must provide an optimum stress distribution around the implant. In this study, for implant overdentures with a bar/clip attachment or a locator attachment, the stress transmitted to the implant in accordance with the change in the denture base length and the vertical pressure was measured and analyzed.
MATERIALS AND METHODS: Test model was created with epoxy resin. The strain gauges made a tight contact with implant surfaces. A universal testing machine was used to exert a vertical pressure on the mandibular implant overdenture and the strain rate of the implants was measured.
RESULTS: Means and standard deviations of the maximum micro-deformation rates were determined. 1) Locator attachment: The implants on the working side generally showed higher strain than those on the non-working side. Tensile force was observed on the mesial surface of the implant on the working side, and the compressive force was applied to the buccal surface and on the surfaces of the implant on the non-working side. 2) Bar/clip attachment: The implants on the both non-working and working sides showed high strain; all surfaces except the mesial surface of the implant on the non-working side showed a compressive force.
CONCLUSION: To minimize the strain on implants in mandibular implant overdentures, the attachment of the implant should be carefully selected and the denture base should be extended as much as possible.

Entities:  

Keywords:  Bar/Clip; Denture Base Length; Locator; Mandibular Overdenture; Stress Analysis

Year:  2017        PMID: 28680544      PMCID: PMC5483399          DOI: 10.4047/jap.2017.9.3.143

Source DB:  PubMed          Journal:  J Adv Prosthodont        ISSN: 2005-7806            Impact factor:   1.904


  21 in total

1.  In vivo forces on oral implants supporting a mandibular overdenture: the influence of attachment system.

Authors:  J Duyck; H Van Oosterwyck; J Vander Sloten; M De Cooman; R Puers; I Naert
Journal:  Clin Oral Investig       Date:  1999-12       Impact factor: 3.573

Review 2.  Mandibular implant overdenture treatment: consensus and controversy.

Authors:  D R Burns
Journal:  J Prosthodont       Date:  2000-03       Impact factor: 2.752

3.  Comparison of load distribution for implant overdenture attachments.

Authors:  Joseph A Porter; Vicki C Petropoulos; John B Brunski
Journal:  Int J Oral Maxillofac Implants       Date:  2002 Sep-Oct       Impact factor: 2.804

Review 4.  The McGill consensus statement on overdentures. Mandibular two-implant overdentures as first choice standard of care for edentulous patients.

Authors:  J S Feine; G E Carlsson; M A Awad; A Chehade; W J Duncan; S Gizani; T Head; G Heydecke; J P Lund; M MacEntee; R Mericske-Stern; P Mojon; J A Morais; I Naert; A G T Payne; J Penrod; G T Stoker; A Tawse-Smith; T D Taylor; J M Thomason; W M Thomson; D Wismeijer
Journal:  Gerodontology       Date:  2002-07       Impact factor: 2.980

5.  Force transmission in bar-retained implant-stabilised mandibular over-dentures: an in-vitro study.

Authors:  Ali M el-Sheikh; John A Hobkirk
Journal:  Eur J Prosthodont Restor Dent       Date:  2002-12

6.  Three-dimensional force measurements on mandibular implants supporting overdentures.

Authors:  R Mericske-Stern; A H Geering; W B Burgin; H Graf
Journal:  Int J Oral Maxillofac Implants       Date:  1992       Impact factor: 2.804

7.  Mandibular implant-retained overdenture: a clinical trial of two anchorage systems.

Authors:  G Menicucci; M Lorenzetti; P Pera; G Preti
Journal:  Int J Oral Maxillofac Implants       Date:  1998 Nov-Dec       Impact factor: 2.804

8.  Complete dentures fixed on dental implants: chewing patterns and implant stress.

Authors:  J Setz; A Krämer; U Benzing; H Weber
Journal:  Int J Oral Maxillofac Implants       Date:  1989       Impact factor: 2.804

Review 9.  Attachment systems for implant retained overdentures: a literature review.

Authors:  Theodoros Trakas; Konstantinos Michalakis; Kiho Kang; Hiroshi Hirayama
Journal:  Implant Dent       Date:  2006-03       Impact factor: 2.454

10.  A three-dimensional, finite-element analysis of bone around dental implants in an edentulous human mandible.

Authors:  H J Meijer; F J Starmans; W H Steen; F Bosman
Journal:  Arch Oral Biol       Date:  1993-06       Impact factor: 2.633

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.