Literature DB >> 10803135

In vivo forces on oral implants supporting a mandibular overdenture: the influence of attachment system.

J Duyck1, H Van Oosterwyck, J Vander Sloten, M De Cooman, R Puers, I Naert.   

Abstract

This study was designed to gain insight into the influence of the attachment system on the loading conditions of oral implants supporting a mandibular overdenture on two implants. Five patients were selected and were provided with two implants in the canine area of the mandible (Brånemark System). All patients received a new mandibular overdenture that could be mounted on an ovoid-shaped bar (Dolder, C&M): (a) with and (b) without bilateral extensions and (c) on ball-attachments (Nobel Biocare). Using three strain gauges attached to the outer surface of the 5.5-mm standard abutments, the axial forces and bending moments on both supporting implants could be quantified. Load registrations were made during application of 50 N on seven predetermined positions along the occlusal surface of the prosthesis and during maximal biting in maximal occlusion (clenching). The results revealed no differences in induced axial force for the various anchorage devices, unlike the differences in bending moment. Although there is a tendency for better axial load sharing with bars and better sharing of bending moments with ball attachments, these differences were not significant.

Entities:  

Mesh:

Substances:

Year:  1999        PMID: 10803135     DOI: 10.1007/s007840050102

Source DB:  PubMed          Journal:  Clin Oral Investig        ISSN: 1432-6981            Impact factor:   3.573


  4 in total

1.  Tissue-supported dental implant prosthesis (overdenture): the search for the ideal protocol. A literature review.

Authors:  Domenica Laurito; Luca Lamazza; Michael J Spink; Alberto De Biase
Journal:  Ann Stomatol (Roma)       Date:  2012-05-03

2.  Stress analysis of mandibular implant overdenture with locator and bar/clip attachment: Comparative study with differences in the denture base length.

Authors:  Jin Suk Yoo; Kung-Rock Kwon; Kwantae Noh; Hyeonjong Lee; Janghyun Paek
Journal:  J Adv Prosthodont       Date:  2017-06-19       Impact factor: 1.904

3.  [Clinical application of mandibular overdenture supported by a two-implant and interforaminal bar in an edentulous atrophic mandible].

Authors:  Dao Li; Xiao Xue; Wang Xiaodong; Zhao Ke
Journal:  Hua Xi Kou Qiang Yi Xue Za Zhi       Date:  2017-08-01

4.  Evaluation of stress distribution of implant-retained mandibular overdenture with different vertical restorative spaces: A finite element analysis.

Authors:  Behnaz Ebadian; Mahmoud Farzin; Saeid Talebi; Niloufar Khodaeian
Journal:  Dent Res J (Isfahan)       Date:  2012-11
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.