Literature DB >> 1398835

Three-dimensional force measurements on mandibular implants supporting overdentures.

R Mericske-Stern1, A H Geering, W B Burgin, H Graf.   

Abstract

The purpose of this study was to determine masticatory and functional forces in three axes on mandibular implants supporting overdentures. Five edentulous test subjects were selected, each having two mandibular implants. Three-dimensional piezoelectric force transducers were mounted on the two-part ITI Bonefit implants and rigidly connected to the denture. Forces in vertical, lateromedial, and anteroposterior directions were measured by means of electrostatic plotter records. The test modalities were light tapping, grinding, maximal occlusal force, and chewing test food. Results showed that the five subjects developed similar stress patterns but quantitatively different occlusal and chewing forces. In all but one subject, reduced maximal occlusal force was found compared to dentate subjects and edentulous subjects with fixed partial prostheses supported by implants. The recordings of chewing cycles when eating test food resulted in very regular rhythmic strokes, similar to those of dentate subjects but with slightly reduced speed. All stress patterns showed that occlusal and chewing forces were mainly directed in vertical, medial, and anterior dimensions. The dominating component was vertical.

Entities:  

Mesh:

Substances:

Year:  1992        PMID: 1398835

Source DB:  PubMed          Journal:  Int J Oral Maxillofac Implants        ISSN: 0882-2786            Impact factor:   2.804


  5 in total

1.  In vitro synchrotron-based radiography of micro-gap formation at the implant-abutment interface of two-piece dental implants.

Authors:  A Rack; T Rack; M Stiller; H Riesemeier; S Zabler; K Nelson
Journal:  J Synchrotron Radiat       Date:  2010-02-03       Impact factor: 2.616

2.  Stress analysis of mandibular implant overdenture with locator and bar/clip attachment: Comparative study with differences in the denture base length.

Authors:  Jin Suk Yoo; Kung-Rock Kwon; Kwantae Noh; Hyeonjong Lee; Janghyun Paek
Journal:  J Adv Prosthodont       Date:  2017-06-19       Impact factor: 1.904

3.  The Effect of Number and Distribution of Mini Dental Implants on Overdenture Stability: An In Vitro Study.

Authors:  Rafif Alshenaiber; Craig Barclay; Nick Silikas
Journal:  Materials (Basel)       Date:  2022-04-20       Impact factor: 3.748

4.  Analysis of Torque Maintenance and Fracture Resistance after Fatigue in Retention Screws Made of Different Metals for Screw-Retained Implant-Borne Prosthesis Joints.

Authors:  Maria Beatriz Bello Taborda; Gabriela Sumie Yaguinuma Gonçalves; Cecília Alves de Sousa; Wirley Gonçalves Assunção
Journal:  Int J Dent       Date:  2021-11-18

5.  Clinical Performance of Implant Crown Retained Removable Partial Dentures for Mandibular Edentulism-A Retrospective Study.

Authors:  Soo-Yeon Yoo; Seong-Kyun Kim; Seong-Joo Heo; Jai-Young Koak; Hye-Rin Jeon
Journal:  J Clin Med       Date:  2021-05-18       Impact factor: 4.241

  5 in total