Complete dentures fixed on dental implants: chewing patterns and implant stress.

J Setz, A Krämer, U Benzing, H Weber.   

Abstract

Electrognathographic measurements on 18 patients with implant-attached mandibular complete dentures showed larger and more stable chewing patterns compared to their former dentures without implants. Strain gauge measurements revealed mechanical stress acting on the implants even during the fixation of the bar. In addition to simulating the periodontal ligament, the intramobile element (IME) of the IMZ system compensated minor, clinically undetectable mismatches inherent with technical procedures (casting, soldering). Although the implants are loaded with tensile and compressive stress, tensile stress dominated during the chewing process. The implants were also loaded during swallowing. This load reached half of the value of the chewing loads.

Entities:  

Mesh:

Substances:

Year:  1989        PMID: 2599581

Source DB:  PubMed          Journal:  Int J Oral Maxillofac Implants        ISSN: 0882-2786            Impact factor:   2.804


  5 in total

1.  Stress analysis of mandibular implant overdenture with locator and bar/clip attachment: Comparative study with differences in the denture base length.

Authors:  Jin Suk Yoo; Kung-Rock Kwon; Kwantae Noh; Hyeonjong Lee; Janghyun Paek
Journal:  J Adv Prosthodont       Date:  2017-06-19       Impact factor: 1.904

2.  Photoelastic stress analysis surrounding implant-supported prosthesis and alveolar ridge on mandibular overdentures.

Authors:  Dorival Pedroso da Silva; Claudia Cazal; Fernanda Campos Sousa de Almeida; Reinaldo Brito E Dias; Rafael Yagüe Ballester
Journal:  Int J Dent       Date:  2010-05-10

Review 3.  Bioengineering Tools Applied to Dentistry: Validation Methods for In Vitro and In Silico Analysis.

Authors:  Jefferson David Melo de Matos; Daher Antonio Queiroz; Leonardo Jiro Nomura Nakano; Valdir Cabral Andrade; Nathália de Carvalho Ramos Ribeiro; Alexandre Luiz Souto Borges; Marco Antonio Bottino; Guilherme da Rocha Scalzer Lopes
Journal:  Dent J (Basel)       Date:  2022-08-04

4.  Clinical Performance of Implant Crown Retained Removable Partial Dentures for Mandibular Edentulism-A Retrospective Study.

Authors:  Soo-Yeon Yoo; Seong-Kyun Kim; Seong-Joo Heo; Jai-Young Koak; Hye-Rin Jeon
Journal:  J Clin Med       Date:  2021-05-18       Impact factor: 4.241

5.  Fracture of abutment screw supporting a cemented implant-retained prosthesis with external hexagon connection: a case report with sem evaluation.

Authors:  Mariana Diniz Bisi Santos; Arthur Braga Pfeifer; Marcos Rogério Pupo Silva; Claudio Luiz Sendyk; Wilson Roberto Sendyk
Journal:  J Appl Oral Sci       Date:  2007-04       Impact factor: 2.698

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.