Literature DB >> 28670841

The sensitivity of 38 heart rate variability measures to the addition of artifact in human and artificial 24-hr cardiac recordings.

Nicolas J C Stapelberg1,2, David L Neumann3, David H K Shum3, Harry McConnell4, Ian Hamilton-Craig5.   

Abstract

BACKGROUND: Artifact is common in cardiac RR interval data derived from 24-hr recordings and has a significant impact on heart rate variability (HRV) measures. However, the relative impact of progressively added artifact on a large group of commonly used HRV measures has not been assessed. This study compared the relative sensitivity of 38 commonly used HRV measures to artifact to determine which measures show the most change with increasing increments of artifact. A secondary aim was to ascertain whether short-term and long-term HRV measures, as groups, share similarities in their sensitivity to artifact.
METHODS: Up to 10% of artifact was added to 20 artificial RR (ARR) files and 20 human cardiac recordings, which had been assessed for artifact by a cardiac technician. The added artifact simulated deletion of RR intervals and insertion of individual short RR intervals. Thirty-eight HRV measures were calculated for each file. Regression analysis was used to rank the HRV measures according to their sensitivity to artifact as determined by the magnitude of slope.
RESULTS: RMSSD, SDANN, SDNN, RR triangular index and TINN, normalized power and relative power linear measures, and most nonlinear methods examined are most robust to artifact.
CONCLUSION: Short-term time domain HRV measures are more sensitive to added artifact than long-term measures. Absolute power frequency domain measures across all frequency bands are more sensitive than normalized and relative frequency domain measures. Most nonlinear HRV measures assessed were relatively robust to added artifact, with Poincare plot SD1 being most sensitive.
© 2017 Wiley Periodicals, Inc.

Entities:  

Keywords:  artifact; clinical, noninvasive techniques-Holter/event recorders; noninvasive technique-heart rate variability

Mesh:

Year:  2017        PMID: 28670841      PMCID: PMC7313264          DOI: 10.1111/anec.12483

Source DB:  PubMed          Journal:  Ann Noninvasive Electrocardiol        ISSN: 1082-720X            Impact factor:   1.468


  56 in total

1.  A direct analytical demonstration of the essential equivalence of detrended fluctuation analysis and spectral analysis of RR interval variability.

Authors:  Keith Willson; Darrel P Francis
Journal:  Physiol Meas       Date:  2003-02       Impact factor: 2.833

2.  Cardiac vagal control in depression: a critical analysis.

Authors:  Jonathan Rottenberg
Journal:  Biol Psychol       Date:  2006-10-12       Impact factor: 3.251

3.  Correction of erroneous and ectopic beats using a point process adaptive algorithm.

Authors:  Riccardo Barbieri; Emery N Brown
Journal:  Conf Proc IEEE Eng Med Biol Soc       Date:  2006

4.  Smartphone-enabled pulse rate variability: an alternative methodology for the collection of heart rate variability in psychophysiological research.

Authors:  James A J Heathers
Journal:  Int J Psychophysiol       Date:  2013-06-08       Impact factor: 2.997

5.  Frequency domain measures of heart period variability and mortality after myocardial infarction.

Authors:  J T Bigger; J L Fleiss; R C Steinman; L M Rolnitzky; R E Kleiger; J N Rottman
Journal:  Circulation       Date:  1992-01       Impact factor: 29.690

6.  ECG artifacts and heart period variability: don't miss a beat!

Authors:  G G Berntson; J R Stowell
Journal:  Psychophysiology       Date:  1998-01       Impact factor: 4.016

7.  Power law behavior of RR-interval variability in healthy middle-aged persons, patients with recent acute myocardial infarction, and patients with heart transplants.

Authors:  J T Bigger; R C Steinman; L M Rolnitzky; J L Fleiss; P Albrecht; R J Cohen
Journal:  Circulation       Date:  1996-06-15       Impact factor: 29.690

8.  Power spectrum analysis of heart rate fluctuation: a quantitative probe of beat-to-beat cardiovascular control.

Authors:  S Akselrod; D Gordon; F A Ubel; D C Shannon; A C Berger; R J Cohen
Journal:  Science       Date:  1981-07-10       Impact factor: 47.728

9.  Depression and heart rate variability in patients with stable coronary heart disease: findings from the Heart and Soul Study.

Authors:  Anil Gehi; Dennis Mangano; Sharon Pipkin; Warren S Browner; Mary A Whooley
Journal:  Arch Gen Psychiatry       Date:  2005-06

10.  Quantitative analysis of heart rate variability.

Authors:  J. Kurths; A. Voss; P. Saparin; A. Witt; H. J. Kleiner; N. Wessel
Journal:  Chaos       Date:  1995-03       Impact factor: 3.642

View more
  9 in total

1.  Prenatal and recent methylmercury exposure and heart rate variability in young adults: the Seychelles Child Development Study.

Authors:  Wojciech Zareba; Sally W Thurston; Grazyna Zareba; Jean Philippe Couderc; Katie Evans; Jean Xia; Gene E Watson; J J Strain; Emeir McSorley; Alison Yeates; Maria Mulhern; Conrad F Shamlaye; Pascal Bovet; Edwin van Wijngaarden; Philip W Davidson; Gary J Myers
Journal:  Neurotoxicol Teratol       Date:  2019-05-23       Impact factor: 3.763

2.  The sensitivity of 38 heart rate variability measures to the addition of artifact in human and artificial 24-hr cardiac recordings.

Authors:  Nicolas J C Stapelberg; David L Neumann; David H K Shum; Harry McConnell; Ian Hamilton-Craig
Journal:  Ann Noninvasive Electrocardiol       Date:  2017-07-02       Impact factor: 1.468

3.  RMSSD Is More Sensitive to Artifacts Than Frequency-Domain Parameters: Implication in Athletes' Monitoring.

Authors:  Nicolas Bourdillon; Sasan Yazdani; Jean-Marc Vesin; Laurent Schmitt; Grégoire P Millet
Journal:  J Sports Sci Med       Date:  2022-06-01       Impact factor: 4.017

Review 4.  Fractal Correlation Properties of Heart Rate Variability as a Biomarker for Intensity Distribution and Training Prescription in Endurance Exercise: An Update.

Authors:  Bruce Rogers; Thomas Gronwald
Journal:  Front Physiol       Date:  2022-05-09       Impact factor: 4.755

5.  Stochastic vagus nerve stimulation affects acute heart rate dynamics in rats.

Authors:  Steven W Lee; Kanchan Kulkarni; Elizabeth M Annoni; Imad Libbus; Bruce H KenKnight; Elena G Tolkacheva
Journal:  PLoS One       Date:  2018-03-28       Impact factor: 3.240

6.  Influence of Artefact Correction and Recording Device Type on the Practical Application of a Non-Linear Heart Rate Variability Biomarker for Aerobic Threshold Determination.

Authors:  Bruce Rogers; David Giles; Nick Draper; Laurent Mourot; Thomas Gronwald
Journal:  Sensors (Basel)       Date:  2021-01-26       Impact factor: 3.576

7.  Estimation of Respiratory Frequency in Women and Men by Kubios HRV Software Using the Polar H10 or Movesense Medical ECG Sensor during an Exercise Ramp.

Authors:  Bruce Rogers; Marcelle Schaffarczyk; Thomas Gronwald
Journal:  Sensors (Basel)       Date:  2022-09-21       Impact factor: 3.847

8.  Heart Rate Variability as Indicator of Clinical State in Depression.

Authors:  Ralf Hartmann; Frank M Schmidt; Christian Sander; Ulrich Hegerl
Journal:  Front Psychiatry       Date:  2019-01-17       Impact factor: 4.157

9.  Impact of Using Different Levels of Threshold-Based Artefact Correction on the Quantification of Heart Rate Variability in Three Independent Human Cohorts.

Authors:  Juan M A Alcantara; Abel Plaza-Florido; Francisco J Amaro-Gahete; Francisco M Acosta; Jairo H Migueles; Pablo Molina-Garcia; Jerzy Sacha; Guillermo Sanchez-Delgado; Borja Martinez-Tellez
Journal:  J Clin Med       Date:  2020-01-23       Impact factor: 4.241

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.