Literature DB >> 9499713

ECG artifacts and heart period variability: don't miss a beat!

G G Berntson1, J R Stowell.   

Abstract

The impact of artifacts on estimates of heart period variability were evaluated by modeling the effects of missed R-waves and spurious R-wave detections in actual and simulated heart period series. Results revealed that even a single artifact, occurring within a 128-s interbeat interval series, can impart substantial spurious variance into all commonly analyzed frequency bands, including that associated with respiratory sinus arrhythmia. In fact, the spurious variance introduced by a single artifact may be greater than that associated with true basal heart period variability and can far exceed typical effect sizes in psychophysiological studies. The effects of artifacts are not related to a specific analytical method and are apparent in both frequency and time domain analyses. Results emphasize the importance of artifact detection and resolution for studies of heart period variability.

Entities:  

Mesh:

Year:  1998        PMID: 9499713

Source DB:  PubMed          Journal:  Psychophysiology        ISSN: 0048-5772            Impact factor:   4.016


  40 in total

1.  Heart rate variability fraction--a new reportable measure of 24-hour R-R interval variation.

Authors:  Maciej Sosnowski; Elaine Clark; Shahid Latif; Peter W Macfarlane; Michal Tendera
Journal:  Ann Noninvasive Electrocardiol       Date:  2005-01       Impact factor: 1.468

2.  Analysis of first-derivative based QRS detection algorithms.

Authors:  Natalia M Arzeno; Zhi-De Deng; Chi-Sang Poon
Journal:  IEEE Trans Biomed Eng       Date:  2008-02       Impact factor: 4.538

3.  Cardiac reactivity during the ascending phase of acute intravenous alcohol exposure and association with subjective perceptions of intoxication in social drinkers.

Authors:  Vatsalya Vatsalya; Reza Momenan; Daniel W Hommer; Vijay A Ramchandani
Journal:  Alcohol Clin Exp Res       Date:  2014-03-21       Impact factor: 3.455

4.  Test-Retest Reliability of Pediatric Heart Rate Variability: A Meta-Analysis.

Authors:  Oren M Weiner; Jennifer J McGrath
Journal:  J Psychophysiol       Date:  2016-07-27       Impact factor: 1.333

5.  Learning by heart-the relationship between resting vagal tone and metacognitive judgments: a pilot study.

Authors:  Judith Meessen; Stefan Sütterlin; Siegfried Gauggel; Thomas Forkmann
Journal:  Cogn Process       Date:  2018-05-23

6.  Uncertainty in heart rate complexity metrics caused by R-peak perturbations.

Authors:  Nicholas J Napoli; Matthew W Demas; Sanjana Mendu; Chad L Stephens; Kellie D Kennedy; Angela R Harrivel; Randall E Bailey; Laura E Barnes
Journal:  Comput Biol Med       Date:  2018-10-17       Impact factor: 4.589

7.  Measurement fidelity of heart rate variability signal processing: the devil is in the details.

Authors:  Denise C Jarrin; Jennifer J McGrath; Sabrina Giovanniello; Paul Poirier; Marie Lambert
Journal:  Int J Psychophysiol       Date:  2012-07-20       Impact factor: 2.997

8.  On the validity of using the Polar RS800 heart rate monitor for heart rate variability research.

Authors:  Daniel S Quintana; James A J Heathers; Andrew H Kemp
Journal:  Eur J Appl Physiol       Date:  2012-07-13       Impact factor: 3.078

9.  Impact of Comorbid Depressive Disorders on Subjective and Physiological Responses to Emotion in Generalized Anxiety Disorder.

Authors:  Saren H Seeley; Douglas S Mennin; Amelia Aldao; Katie A McLaughlin; Jonathan Rottenberg; David M Fresco
Journal:  Cognit Ther Res       Date:  2015-12-12

10.  Stress recovery during exposure to nature sound and environmental noise.

Authors:  Jesper J Alvarsson; Stefan Wiens; Mats E Nilsson
Journal:  Int J Environ Res Public Health       Date:  2010-03-11       Impact factor: 3.390

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.