Literature DB >> 28663845

Reduction of frame rate in full-field swept-source optical coherence tomography by numerical motion correction [Invited].

Clara Pfäffle1, Hendrik Spahr2, Dierck Hillmann3, Helge Sudkamp1, Gesa Franke1,2, Peter Koch1, Gereon Hüttmann1,2.   

Abstract

Full-field swept-source optical coherence tomography (FF-SS-OCT) was recently shown to allow new and exciting applications for imaging the human eye that were previously not possible using current scanning OCT systems. However, especially when using cameras that do not acquire data with hundreds of kHz frame rate, uncorrected phase errors due to axial motion of the eye lead to a drastic loss in image quality of the reconstructed volumes. Here we first give a short overview of recent advances in techniques and applications of parallelized OCT and finally present an iterative and statistical algorithm that estimates and corrects motion-induced phase errors in the FF-SS-OCT data. The presented algorithm is in many aspects adopted from the phase gradient autofocus (PGA) method, which is frequently used in synthetic aperture radar (SAR). Following this approach, the available phase errors can be estimated based on the image information that remains in the data, and no parametrization with few degrees of freedom is required. Consequently, the algorithm is capable of compensating even strong motion artifacts. Efficacy of the algorithm was tested on simulated data with motion containing varying frequency components. We show that even in strongly blurred data, the actual image information remains intact, and the algorithm can identify the phase error and correct it. Furthermore, we use the algorithm to compensate real phase error in FF-SS-OCT imaging of the human retina. Acquisition rates can be reduced by a factor of three (from 60 to 20 kHz frame rate) with an image quality that is even higher compared to uncorrected volumes recorded at the maximum acquisition rate. The presented algorithm for axial motion correction decreases the high requirements on the camera frame rate and thus brings FF-SS-OCT closer to clinical applications.

Entities:  

Keywords:  (100.3020) Image reconstruction-restoration; (110.4500) Optical coherence tomography

Year:  2017        PMID: 28663845      PMCID: PMC5480560          DOI: 10.1364/BOE.8.001499

Source DB:  PubMed          Journal:  Biomed Opt Express        ISSN: 2156-7085            Impact factor:   3.732


  21 in total

1.  Computational adaptive optics for broadband optical interferometric tomography of biological tissue.

Authors:  Steven G Adie; Benedikt W Graf; Adeel Ahmad; P Scott Carney; Stephen A Boppart
Journal:  Proc Natl Acad Sci U S A       Date:  2012-04-26       Impact factor: 11.205

2.  Wavelength-scanning digital interference holography for tomographic three-dimensional imaging by use of the angular spectrum method.

Authors:  Lingfeng Yu; Myung K Kim
Journal:  Opt Lett       Date:  2005-08-15       Impact factor: 3.776

3.  Ultrahigh-resolution, high-speed, Fourier domain optical coherence tomography and methods for dispersion compensation.

Authors:  Maciej Wojtkowski; Vivek Srinivasan; Tony Ko; James Fujimoto; Andrzej Kowalczyk; Jay Duker
Journal:  Opt Express       Date:  2004-05-31       Impact factor: 3.894

4.  Parallel Fourier domain optical coherence tomography for in vivo measurement of the human eye.

Authors:  Branislav Grajciar; Michael Pircher; Adolf Fercher; Rainer Leitgeb
Journal:  Opt Express       Date:  2005-02-21       Impact factor: 3.894

5.  Multi-MHz retinal OCT.

Authors:  Thomas Klein; Wolfgang Wieser; Lukas Reznicek; Aljoscha Neubauer; Anselm Kampik; Robert Huber
Journal:  Biomed Opt Express       Date:  2013-08-30       Impact factor: 3.732

6.  High-speed three-dimensional human retinal imaging by line-field spectral domain optical coherence tomography.

Authors:  Yoshifumi Nakamura; Shuichi Makita; Masahiro Yamanari; Masahide Itoh; Toyohiko Yatagai; Yoshiaki Yasuno
Journal:  Opt Express       Date:  2007-06-11       Impact factor: 3.894

7.  Interferometric synthetic aperture microscopy.

Authors:  Tyler S Ralston; Daniel L Marks; P Scott Carney; Stephen A Boppart
Journal:  Nat Phys       Date:  2007-02-01       Impact factor: 20.034

8.  Line-field parallel swept source MHz OCT for structural and functional retinal imaging.

Authors:  Daniel J Fechtig; Branislav Grajciar; Tilman Schmoll; Cedric Blatter; Rene M Werkmeister; Wolfgang Drexler; Rainer A Leitgeb
Journal:  Biomed Opt Express       Date:  2015-02-04       Impact factor: 3.732

9.  Computational high-resolution optical imaging of the living human retina.

Authors:  Nathan D Shemonski; Fredrick A South; Yuan-Zhi Liu; Steven G Adie; P Scott Carney; Stephen A Boppart
Journal:  Nat Photonics       Date:  2015       Impact factor: 38.771

10.  Aberration-free volumetric high-speed imaging of in vivo retina.

Authors:  Dierck Hillmann; Hendrik Spahr; Carola Hain; Helge Sudkamp; Gesa Franke; Clara Pfäffle; Christian Winter; Gereon Hüttmann
Journal:  Sci Rep       Date:  2016-10-20       Impact factor: 4.379

View more
  4 in total

1.  Introduction to the feature issue on the 25 year anniversary of optical coherence tomography.

Authors:  Joseph A Izatt; Stephen Boppart; Brett Bouma; Johannes de Boer; Wolfgang Drexler; Xingde Li; Yoshiaki Yasuno
Journal:  Biomed Opt Express       Date:  2017-06-15       Impact factor: 3.732

2.  Optical phase modulation by natural eye movements: application to time-domain FF-OCT image retrieval.

Authors:  Viacheslav Mazlin; Peng Xiao; Kristina Irsch; Jules Scholler; Kassandra Groux; Kate Grieve; Mathias Fink; A Claude Boccara
Journal:  Biomed Opt Express       Date:  2022-01-21       Impact factor: 3.732

3.  Live video rate volumetric OCT imaging of the retina with multi-MHz A-scan rates.

Authors:  Jan Philip Kolb; Wolfgang Draxinger; Julian Klee; Tom Pfeiffer; Matthias Eibl; Thomas Klein; Wolfgang Wieser; Robert Huber
Journal:  PLoS One       Date:  2019-03-28       Impact factor: 3.240

4.  Normalized field autocorrelation function-based optical coherence tomography three-dimensional angiography.

Authors:  Jianbo Tang; Sefik Evren Erdener; Smrithi Sunil; David A Boas
Journal:  J Biomed Opt       Date:  2019-03       Impact factor: 3.170

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.