High-speed three-dimensional human retinal imaging by line-field spectral domain optical coherence tomography.

Yoshifumi Nakamura, Shuichi Makita, Masahiro Yamanari, Masahide Itoh, Toyohiko Yatagai, Yoshiaki Yasuno.   

Abstract

Line-field spectral domain optical coherence tomography (LF-SDOCT) has been developed for very high-speed three-dimensional (3D) retinal imaging. By this technique, the A-line rate significantly improved to 823,200 A-lines/s for single frame imaging and 51,500 A-lines/s for continues frame imaging. The frame rate at continues frame imaging is 201 fps. This 3D acquisition speed is more than two fold higher acquisition speed than the standard flying spot SD-OCT. In this paper, the integration time of the camera was optimized for the in vivo retinal measurement and the degradation of the lateral resolution due to the ocular aberrations was suppressed by introducing the pupil stop. Owing to an optimal integration time, the motion artifact can be significantly suppressed. Also a pupil stop was employed in order to enhance the contrast of the OCT image for the effect of ocular aberrations. The in vivo 3D retinal imaging with 256 cross-sectional images (256 A-lines/image) was successfully performed in 1.3 seconds, corresponding to 0.8 volume/s. The maximum on-axis system sensitivity was measured to be 89.4 dB at a depth of 112 mum with an axial resolution of 7.4 mum in tissue. It is shown that LF-SDOCT might have a sensitivity advantage in comparison to the flying spot SD-OCT in the ultra high-speed acquisition mode.

Entities:  

Year:  2007        PMID: 19547028     DOI: 10.1364/oe.15.007103

Source DB:  PubMed          Journal:  Opt Express        ISSN: 1094-4087            Impact factor:   3.894


  15 in total

1.  Snapshot 3D optical coherence tomography system using image mapping spectrometry.

Authors:  Thuc-Uyen Nguyen; Mark C Pierce; Laura Higgins; Tomasz S Tkaczyk
Journal:  Opt Express       Date:  2013-06-03       Impact factor: 3.894

2.  High definition live 3D-OCT in vivo: design and evaluation of a 4D OCT engine with 1 GVoxel/s.

Authors:  Wolfgang Wieser; Wolfgang Draxinger; Thomas Klein; Sebastian Karpf; Tom Pfeiffer; Robert Huber
Journal:  Biomed Opt Express       Date:  2014-08-06       Impact factor: 3.732

3.  Line-field parallel swept source MHz OCT for structural and functional retinal imaging.

Authors:  Daniel J Fechtig; Branislav Grajciar; Tilman Schmoll; Cedric Blatter; Rene M Werkmeister; Wolfgang Drexler; Rainer A Leitgeb
Journal:  Biomed Opt Express       Date:  2015-02-04       Impact factor: 3.732

4.  Design and optimization of line-field optical coherence tomography at visible wavebands.

Authors:  Fangjian Xing; Jang-Hoon Lee; Collin Polucha; Jonghwan Lee
Journal:  Biomed Opt Express       Date:  2021-02-09       Impact factor: 3.732

5.  Twenty-five years of optical coherence tomography: the paradigm shift in sensitivity and speed provided by Fourier domain OCT [Invited].

Authors:  Johannes F de Boer; Rainer Leitgeb; Maciej Wojtkowski
Journal:  Biomed Opt Express       Date:  2017-06-15       Impact factor: 3.732

6.  Ultra-fast line-field low coherence holographic elastography using spatial phase shifting.

Authors:  Chih-Hao Liu; Alexander Schill; Raksha Raghunathan; Chen Wu; Manmohan Singh; Zhaolong Han; Achuth Nair; Kirill V Larin
Journal:  Biomed Opt Express       Date:  2017-01-23       Impact factor: 3.732

Review 7.  High-speed OCT light sources and systems [Invited].

Authors:  Thomas Klein; Robert Huber
Journal:  Biomed Opt Express       Date:  2017-01-13       Impact factor: 3.732

8.  Reduction of frame rate in full-field swept-source optical coherence tomography by numerical motion correction [Invited].

Authors:  Clara Pfäffle; Hendrik Spahr; Dierck Hillmann; Helge Sudkamp; Gesa Franke; Peter Koch; Gereon Hüttmann
Journal:  Biomed Opt Express       Date:  2017-02-13       Impact factor: 3.732

9.  Laser applications and system considerations in ocular imaging.

Authors:  Ann E Elsner; Matthew S Muller
Journal:  Laser Photon Rev       Date:  2008-10-01       Impact factor: 13.138

10.  Non-contact single shot elastography using line field low coherence holography.

Authors:  Chih-Hao Liu; Alexander Schill; Chen Wu; Manmohan Singh; Kirill V Larin
Journal:  Biomed Opt Express       Date:  2016-07-12       Impact factor: 3.732

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.