Literature DB >> 28658916

Evaluation of Surface Microhardness Following Chemical and Microwave Disinfection of Commercially Available Acrylic Resin Denture Teeth.

Nitasha Gandhi1, Smitha Daniel2, Sushant Benjamin2, Nirmal Kurian2, Vinaya Susan Varghese3.   

Abstract

INTRODUCTION: Denture disinfection is an indispensable procedure for preventing cross contamination and the maintenance of a healthy oral mucosa in patients rehabilitated with removable dental prosthesis. Nevertheless, they are known to cause changes in the physical and mechanical properties of denture base resins and acrylic resin denture teeth following immersion of a denture in a suitable chemical disinfectant solution or by undergoing microwave irradiation. One such mechanical property indicator for artificial tooth materials is hardness. AIM: To assess the surface hardness of acrylic resin teeth of three different commercial brands (Ivoclar, Newace, Acryrock) following chemical (2% glutaraldehyde, 1% sodium hypochlorite) and microwave disinfections.
MATERIALS AND METHODS: Ten specimens of each of the three commercial brands were made for control and each simulated disinfection type and stored in distilled water at room temperature for 24 hours. After water storage, specimens were immersed in 2% glutaraldehyde and 1% sodium hypochlorite (one and three cycles) at room temperature for 10 minutes. Irradiation with microwave (one and three cycles) was done in domestic microwave for three minutes with the specimens immersed in 150 ml of distilled water. The specimens were stored in distilled water at room temperature for seven days after each disinfection cycle. Vickers hardness measurements were made using a hardness indenter under a load of 50 g force for 10 seconds. Data was subjected to repeated measure two-way ANOVA test and Tukey's test.
RESULTS: There were statistically significant differences for the variables disinfection, tooth, and cycle (p<0.05 for teeth &amp; disinfectant interaction, p<0.05 cycle and disinfectant interaction). The mean surface hardness following one microwave disinfection cycle was lower than control, glutaraldehyde and sodium hypochlorite. Comparison among cycles revealed that microhardness was significantly decreased for three cycles of microwave disinfection.
CONCLUSION: It was concluded that there was no significant difference in microhardness when the teeth were subjected to chemical disinfection but three cycles of microwave disinfection produced decrease in the microhardness of different types of artificial teeth.

Entities:  

Keywords:  Acrylic teeth; Cross contamination; Vickers hardness

Year:  2017        PMID: 28658916      PMCID: PMC5483818          DOI: 10.7860/JCDR/2017/27587.9944

Source DB:  PubMed          Journal:  J Clin Diagn Res        ISSN: 0973-709X


  26 in total

1.  Effectiveness of microwave irradiation on the disinfection of complete dentures.

Authors:  Mariana Montenegro Silva; Carlos Eduardo Vergani; Eunice Teresinha Giampaolo; Karin Hermana Neppelenbroek; Denise Madalena Palomari Spolidorio; Ana Lúcia Machado
Journal:  Int J Prosthodont       Date:  2006 May-Jun       Impact factor: 1.681

2.  Effect of disinfectants on the hardness and roughness of reline acrylic resins.

Authors:  Andrea Azevedo; Ana Lucia Machado; Carlos Eduardo Vergani; Eunice Teresinha Giampaolo; Ana Cláudia Pavarina; Romeo Magnani
Journal:  J Prosthodont       Date:  2006 Jul-Aug       Impact factor: 2.752

3.  Microwave disinfection of dentures for the treatment of oral candidiasis.

Authors:  D W Banting; S A Hill
Journal:  Spec Care Dentist       Date:  2001

4.  Hardness of heat-polymerized acrylic resins after disinfection and long-term water immersion.

Authors:  Karin Hermana Neppelenbroek; Ana Cláudia Pavarina; Carlos Eduardo Vergani; Eunice Teresinha Giampaolo
Journal:  J Prosthet Dent       Date:  2005-02       Impact factor: 3.426

5.  In vitro wear resistance, hardness and elastic modulus of artificial denture teeth.

Authors:  Pii Suwannaroop; Pisaisit Chaijareenont; Natthavoot Koottathape; Hidekazu Takahashi; Mansuang Arksornnukit
Journal:  Dent Mater J       Date:  2011-07-21       Impact factor: 2.102

6.  Effect of chemical and microwave disinfection on the surface microhardness of acrylic resin denture teeth.

Authors:  Ligia Regina Vasconcelos; Rafael Leonardo Xediek Consani; Marcelo Ferraz Mesquita; Mário Alexandre Coelho Sinhoreti
Journal:  J Prosthodont       Date:  2013-02-06       Impact factor: 2.752

7.  An in vitro study into the effect of a limited range of denture cleaners on surface roughness and removal of Candida albicans from conventional heat-cured acrylic resin denture base material.

Authors:  Z Harrison; A Johnson; C W I Douglas
Journal:  J Oral Rehabil       Date:  2004-05       Impact factor: 3.837

8.  Effect of the physical properties of acrylic resin of overnight immersion in sodium hypochlorite solution.

Authors:  Letícia Resende Davi; Amanda Peracini; Nathália de Queiroz Ribeiro; Rafael Bellini Soares; Cláudia Helena Lovato da Silva; Helena de Freitas Oliveira Paranhos; Raphael Freitas de Souza
Journal:  Gerodontology       Date:  2010-12       Impact factor: 2.980

9.  Hardness and surface roughness of reline and denture base acrylic resins after repeated disinfection procedures.

Authors:  Ana Lucia Machado; Larry C Breeding; Carlos Eduardo Vergani; Luciano Elias da Cruz Perez
Journal:  J Prosthet Dent       Date:  2009-08       Impact factor: 3.426

10.  Compositional characteristics and hardness of acrylic and composite resin artificial teeth.

Authors:  Paola G Loyaga-Rendon; Hidekazu Takahashi; Iwao Hayakawa; Naohiko Iwasaki
Journal:  J Prosthet Dent       Date:  2007-08       Impact factor: 3.426

View more
  2 in total

1.  Optimization of antimicrobial efficiency of silver nanoparticles against three oral microorganisms in irreversible hydrocolloid impressions.

Authors:  Ahmad Jafari; Ramin Mazaheri Nezhad Fard; Sima Shahabi; Farid Abbasi; Golshid Javdani Shahedin; Ronak Bakhtiari
Journal:  Iran J Microbiol       Date:  2021-12

2.  Effects of incorporation of 2.5 and 5 wt% TiO2 nanotubes on fracture toughness, flexural strength, and microhardness of denture base poly methyl methacrylate (PMMA).

Authors:  Sahar Abdulrazzaq Naji; Marjan Behroozibakhsh; Tahereh Sadat Jafarzadeh Kashi; Hossein Eslami; Reza Masaeli; Hosseinali Mahgoli; Mohammadreza Tahriri; Mehrsima Ghavvami Lahiji; Vahid Rakhshan
Journal:  J Adv Prosthodont       Date:  2018-04-18       Impact factor: 1.904