Literature DB >> 23387984

Effect of chemical and microwave disinfection on the surface microhardness of acrylic resin denture teeth.

Ligia Regina Vasconcelos1, Rafael Leonardo Xediek Consani, Marcelo Ferraz Mesquita, Mário Alexandre Coelho Sinhoreti.   

Abstract

PURPOSE: The purpose of this study was to evaluate the effect of simulated disinfections (2% glutaraldehyde, 1% sodium hypochlorite, and microwave energy) on the surface hardness of Trilux, Biocler, Biotone, New Ace, and Magister commercial artificial teeth.
MATERIALS AND METHODS: Specimens (n = 10) were made with the teeth included individually in circular blocks of acrylic resin, leaving the labial surface exposed. Cycles of simulated chemical disinfection were accomplished with the specimens immersed in the solutions at room temperature for 10 minutes, followed by tap water washing for 30 seconds and storage in distilled water at room temperature for 7 days until the next disinfection. Simulated disinfection by microwave energy was carried out in a domestic oven with 1300 W at a potency of 50% for 3 minutes with the specimens individually immersed in 150 ml of distilled water. Control (no disinfection) and the experimental groups (first and third disinfection cycles) were submitted to Knoop hardness measurements with indentations at the center of the labial tooth surface. Data were submitted to repeated measure two-way ANOVA and Tukey's test (α = 0.05).
RESULTS: Biocler, Magister, and Trilux showed lower surface microhardness when submitted to microwave. Lower microhardness for Biotone was promoted by hypochlorite, while no significant difference was shown for New Ace. The third disinfection cycle significantly decreased the tooth surface hardness only for microwave.
CONCLUSIONS: Different disinfection methods promoted different effects on the microhardness of different types of artificial teeth. Surface microhardness of the teeth was less affected by the simulated chemical disinfections when compared to microwaved specimens.
© 2013 by the American College of Prosthodontists.

Entities:  

Mesh:

Substances:

Year:  2013        PMID: 23387984     DOI: 10.1111/jopr.12009

Source DB:  PubMed          Journal:  J Prosthodont        ISSN: 1059-941X            Impact factor:   2.752


  5 in total

1.  Evaluation of Surface Microhardness Following Chemical and Microwave Disinfection of Commercially Available Acrylic Resin Denture Teeth.

Authors:  Nitasha Gandhi; Smitha Daniel; Sushant Benjamin; Nirmal Kurian; Vinaya Susan Varghese
Journal:  J Clin Diagn Res       Date:  2017-05-01

Review 2.  The Effect of Microwave Disinfection on Denture Base Polymers, Liners and Teeth: A Basic Overview.

Authors:  Theodoros Klironomos; Aspasia Katsimpali; Gregory Polyzois
Journal:  Acta Stomatol Croat       Date:  2015-09

3.  Bond strength of veneer ceramic and zirconia cores with different surface modifications after microwave sintering.

Authors:  Muhammet Saka; Bulem Yuzugullu
Journal:  J Adv Prosthodont       Date:  2013-11-28       Impact factor: 1.904

4.  Effect of different denture cleansers on surface roughness and microhardness of artificial denture teeth.

Authors:  Bulem Yuzugullu; Ozlem Acar; Cem Cetinsahin; Cigdem Celik
Journal:  J Adv Prosthodont       Date:  2016-10-21       Impact factor: 1.904

5.  Effect of Repeated Microwave Disinfection on the Surface Hardness of a Heat-Cured Denture Base Resin: An In vitro Study.

Authors:  Priti Jaiswal; Neelam Pande; Rajlakshmi Banerjee; Usha Radke
Journal:  Contemp Clin Dent       Date:  2018 Jul-Sep
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.