Hardness of heat-polymerized acrylic resins after disinfection and long-term water immersion.

Karin Hermana Neppelenbroek1, Ana Cláudia Pavarina, Carlos Eduardo Vergani, Eunice Teresinha Giampaolo.   

Abstract

STATEMENT OF THE PROBLEM: In selecting a disinfectant for dental prostheses, compatibility between the disinfectant and the type of denture base material must be considered to avoid adverse effects on the hardness of the acrylic resin.
PURPOSE: This study investigated the hardness of 2 denture base resins after disinfection and long-term water immersion.
MATERIAL AND METHODS: Thirty-two disk-shaped specimens (13 mm in diameter and 8 mm thick) were fabricated from each resin (Lucitone 550 and QC-20), polished, stored in water at 37 degrees C for 48 hours, and submitted to hardness tests (Vickers hardness number [VHN]) before disinfection. Disinfection methods included scrubbing with 4% chlorhexidine gluconate for 1 minute, immersion for 10 minutes in 1 of the tested disinfectant solutions (n=8) (3.78% sodium perborate, 4% chlorhexidine gluconate, or 1% sodium hypochorite), and immersion in water for 3 minutes. The disinfection procedures were repeated 4 times, and 12 hardness measurements were made on each specimen. Control specimens (not disinfected) were stored in water for 56 minutes. Hardness tests (VHN) were also performed after 15, 30, 60, 90, and 120 days of storage in water. Statistical analyses of data were conducted with a repeated measures 3-way analysis of variance (ANOVA) and Tukey post-hoc test (alpha=.05).
RESULTS: Mean values +/- SD for Lucitone 550 (16.52 +/- 0.94 VHN) and QC-20 (9.61 +/- 0.62 VHN) demonstrated a significant (P <.05) decrease in hardness after disinfection, regardless of material and disinfectant solutions used (Lucitone 550: 15.25 +/- 0.74; QC-20: 8.09 +/- 0.39). However, this effect was reversed after 15 days of storage in water. Both materials exhibited a continuous increase (P <.05) in hardness values for up to 60 days of water storage, after which no significant change was observed.
CONCLUSION: Within the limitations of this in vitro study, QC-20 and Lucitone 550 specimens exhibited significantly lower hardness values after disinfection regardless of the disinfectant solution used.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 15674229     DOI: 10.1016/j.prosdent.2004.10.020

Source DB:  PubMed          Journal:  J Prosthet Dent        ISSN: 0022-3913            Impact factor:   3.426


  14 in total

1.  Evaluation of Surface Microhardness Following Chemical and Microwave Disinfection of Commercially Available Acrylic Resin Denture Teeth.

Authors:  Nitasha Gandhi; Smitha Daniel; Sushant Benjamin; Nirmal Kurian; Vinaya Susan Varghese
Journal:  J Clin Diagn Res       Date:  2017-05-01

2.  The Beneficial Effect of Equisetum giganteum L. against Candida Biofilm Formation: New Approaches to Denture Stomatitis.

Authors:  Rafaela A S Alavarce; Luiz L Saldanha; Nara Ligia M Almeida; Vinicius C Porto; Anne L Dokkedal; Vanessa S Lara
Journal:  Evid Based Complement Alternat Med       Date:  2015-07-28       Impact factor: 2.629

3.  Comparative Evaluation of Effect of Water Absorption on the Surface Properties of Heat Cure Acrylic: An in vitro Study.

Authors:  G S Chandu; Pooja Asnani; Siddarth Gupta; Mohd Faisal Khan
Journal:  J Int Oral Health       Date:  2015-04

4.  Changes in roughness of denture base and reline materials by chemical disinfection or microwave irradiation: surface roughness of denture base and reline materials.

Authors:  Ana Lucia Machado; Eunice Teresinha Giampaolo; Carlos Eduardo Vergani; Juliana Feltrin de Souza; Janaina Habib Jorge
Journal:  J Appl Oral Sci       Date:  2011-10       Impact factor: 2.698

5.  A Comparative Clinical Study of the Effect of Denture Cleansing on the Surface Roughness and Hardness of Two Denture Base Materials.

Authors:  Amani Ramadan Moussa; Wessam Mohamed Dehis; Asmaa Nabil Elboraey; Hisham Samir ElGabry
Journal:  Open Access Maced J Med Sci       Date:  2016-08-22

6.  The effect of acrylamide incorporation on the thermal and physical properties of denture resins.

Authors:  Elif Aydogan Ayaz; Rukiye Durkan; Bora Bagis
Journal:  J Adv Prosthodont       Date:  2013-05-30       Impact factor: 1.904

7.  Effect of denture-coating composite on Candida albicans biofilm and surface degradation after disinfection protocol.

Authors:  Matheus Jacobina Silva; Denise G de Oliveira; Oscar O Marcillo; Karin H Neppelenbroek; Vanessa S Lara; Vinícius C Porto
Journal:  Int Dent J       Date:  2016-01-07       Impact factor: 2.607

8.  Bond strength of hard chairside reline resins to a rapid polymerizing denture base resin before and after thermal cycling.

Authors:  Karin Hermana Neppelenbroek; Ana Cláudia Pavarina; Mauricio Neves Gomes; Ana Lucia Machado; Carlos Eduardo Vergani
Journal:  J Appl Oral Sci       Date:  2006-12       Impact factor: 2.698

9.  Effect of denture wearing on occurrence of fungal Isolates in the oral cavity: A pilot study.

Authors:  Shushant K Garg; Varsha A Singh; Sandeep K Garg; Sanjeev Mittal; Gagandeep K Chahal
Journal:  J Clin Exp Dent       Date:  2012-04-01

10.  Effect of a post-polymerization treatments on the flexural strength and Vickers hardness of reline and acrylic denture base resins.

Authors:  Rosangela Seiko Seo; Carlos Eduardo Vergani; Eunice Teresinha Giampaolo; Ana Claudia Pavarina; Ana Lucia Machado
Journal:  J Appl Oral Sci       Date:  2007-12       Impact factor: 2.698

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.