Literature DB >> 28656461

Comparison of radial 4D Flow-MRI with perivascular ultrasound to quantify blood flow in the abdomen and introduction of a porcine model of pre-hepatic portal hypertension.

A Frydrychowicz1,2,3, A Roldan-Alzate4,5, E Winslow6, D Consigny4, C A Campo4, U Motosugi4, K M Johnson7, O Wieben4,7, S B Reeder4,7,8,9,10.   

Abstract

OBJECTIVES: Objectives of this study were to compare radial time-resolved phase contrast magnetic resonance imaging (4D Flow-MRI) with perivascular ultrasound (pvUS) and to explore a porcine model of acute pre-hepatic portal hypertension (PHTN).
METHODS: Abdominal 4D Flow-MRI and pvUS in portal and splenic vein, hepatic and both renal arteries were performed in 13 pigs of approximately 60 kg. In six pigs, measurements were repeated after partial portal vein (PV) ligature. Inter- and intra-reader comparisons and statistical analysis including Bland-Altman (BA) comparison, paired Student's t tests and linear regression were performed.
RESULTS: PvUS and 4D Flow-MRI measurements agreed well; flow before partial PV ligature was 322 ± 30 ml/min in pvUS and 297 ± 27 ml/min in MRI (p = 0.294), and average BA difference was 25 ml/min [-322; 372]. Inter- and intra-reader results differed very little, revealed excellent correlation (R 2 = 0.98 and 0.99, respectively) and resulted in BA differences of -5 ml/min [-161; 150] and -2 ml/min [-28; 25], respectively. After PV ligature, PV flow decreased from 356 ± 50 to 298 ± 61 ml/min (p = 0.02), and hepatic arterial flow increased from 277 ± 36 to 331 ± 65 ml/min (p = n.s.).
CONCLUSION: The successful in vivo comparison of radial 4D Flow-MRI to perivascular ultrasound revealed good agreement of abdominal blood flow although with considerable spread of results. A model of pre-hepatic PHTN was successfully introduced and acute responses monitored. KEY POINTS: • Radial 4D Flow-MRI in the abdomen was successfully compared to perivascular ultrasound. • Inter- and intra-reader testing demonstrated excellent reproducibility of upper abdominal 4D Flow-MRI. • A porcine model of acute pre-hepatic portal hypertension was successfully introduced. • 4D Flow-MRI successfully monitored acute changes in a model of portal hypertension.

Entities:  

Keywords:  4D Flow-MRI; Animal model; Blood flow; Phase contrast magnetic resonance imaging; Portal hypertension

Mesh:

Year:  2017        PMID: 28656461      PMCID: PMC5675776          DOI: 10.1007/s00330-017-4862-4

Source DB:  PubMed          Journal:  Eur Radiol        ISSN: 0938-7994            Impact factor:   5.315


  42 in total

Review 1.  Complications of cirrhosis. I. Portal hypertension.

Authors:  J Bosch; J C García-Pagán
Journal:  J Hepatol       Date:  2000       Impact factor: 25.083

2.  PC VIPR: a high-speed 3D phase-contrast method for flow quantification and high-resolution angiography.

Authors:  Tianliang Gu; Frank R Korosec; Walter F Block; Sean B Fain; Quill Turk; Darren Lum; Yong Zhou; Thomas M Grist; Victor Haughton; Charles A Mistretta
Journal:  AJNR Am J Neuroradiol       Date:  2005-04       Impact factor: 3.825

Review 3.  Animal models of portal hypertension.

Authors:  Juan-G Abraldes; Marcos Pasarín; Juan-Carlos García-Pagán
Journal:  World J Gastroenterol       Date:  2006-11-07       Impact factor: 5.742

4.  Inverse thermodilution with conventional pulmonary artery catheters for the assessment of cerebral, hepatic, renal, and femoral blood flow.

Authors:  Christoph C Ganter; Christof Buser; Matthias Haenggi; Hanswilly Mattes; Jukka Takala; Stephan M Jakob
Journal:  Shock       Date:  2009-08       Impact factor: 3.454

5.  Highly k-t-space-accelerated phase-contrast MRI.

Authors:  Bernd Jung; Matthias Honal; Peter Ullmann; Jürgen Hennig; Michael Markl
Journal:  Magn Reson Med       Date:  2008-11       Impact factor: 4.668

6.  Quantitative 2D and 3D phase contrast MRI: optimized analysis of blood flow and vessel wall parameters.

Authors:  A F Stalder; M F Russe; A Frydrychowicz; J Bock; J Hennig; M Markl
Journal:  Magn Reson Med       Date:  2008-11       Impact factor: 4.668

7.  Four-dimensional (4D) flow of the whole heart and great vessels using real-time respiratory self-gating.

Authors:  Sergio Uribe; Philipp Beerbaum; Thomas Sangild Sørensen; Allan Rasmusson; Reza Razavi; Tobias Schaeffter
Journal:  Magn Reson Med       Date:  2009-10       Impact factor: 4.668

8.  Effect of portal hypertension on splenic blood flow, intrasplenic extravasation and systemic blood pressure.

Authors:  Susan Kaufman; Jody Levasseur
Journal:  Am J Physiol Regul Integr Comp Physiol       Date:  2003-06       Impact factor: 3.619

9.  Validation of magnetic resonance phase-contrast flow measurements in the main pulmonary artery and aorta using perivascular ultrasound in a large animal model.

Authors:  Sebastian Ley; Roland Unterhinninghofen; Julia Ley-Zaporozhan; Jens-Peter Schenk; Hans-Ulrich Kauczor; Gabor Szabo
Journal:  Invest Radiol       Date:  2008-06       Impact factor: 6.016

Review 10.  The clinical use of HVPG measurements in chronic liver disease.

Authors:  Jaime Bosch; Juan G Abraldes; Annalisa Berzigotti; Juan Carlos García-Pagan
Journal:  Nat Rev Gastroenterol Hepatol       Date:  2009-09-01       Impact factor: 46.802

View more
  9 in total

1.  In Vitro Assessment of Flow Variability in an Intracranial Aneurysm Model Using 4D Flow MRI and Tomographic PIV.

Authors:  Rafael Medero; Katrina Ruedinger; David Rutkowski; Kevin Johnson; Alejandro Roldán-Alzate
Journal:  Ann Biomed Eng       Date:  2020-06-10       Impact factor: 3.934

Review 2.  Noninvasive imaging assessment of portal hypertension.

Authors:  Paul Kennedy; Octavia Bane; Stefanie J Hectors; Aaron Fischman; Thomas Schiano; Sara Lewis; Bachir Taouli
Journal:  Abdom Radiol (NY)       Date:  2020-09-14

3.  Hemodynamic measurements with an abdominal 4D flow MRI sequence with spiral sampling and compressed sensing in patients with chronic liver disease.

Authors:  Octavia Bane; Steven Peti; Mathilde Wagner; Stefanie Hectors; Hadrien Dyvorne; Michael Markl; Bachir Taouli
Journal:  J Magn Reson Imaging       Date:  2018-10-14       Impact factor: 4.813

4.  Four-dimensional Flow MRI as a Marker for Risk Stratification of Gastroesophageal Varices in Patients with Liver Cirrhosis.

Authors:  Utaroh Motosugi; Alejandro Roldán-Alzate; Peter Bannas; Adnan Said; Sean Kelly; Ryan Zea; Oliver Wieben; Scott B Reeder
Journal:  Radiology       Date:  2018-10-16       Impact factor: 11.105

Review 5.  4D Flow MRI in the portal venous system: imaging and analysis methods, and clinical applications.

Authors:  Ryota Hyodo; Yasuo Takehara; Shinji Naganawa
Journal:  Radiol Med       Date:  2022-09-19       Impact factor: 6.313

Review 6.  Abdominal applications of quantitative 4D flow MRI.

Authors:  Thekla H Oechtering; Grant S Roberts; Nikolaos Panagiotopoulos; Oliver Wieben; Alejandro Roldán-Alzate; Scott B Reeder
Journal:  Abdom Radiol (NY)       Date:  2021-11-27

Review 7.  Noninvasive imaging of hepatic dysfunction: A state-of-the-art review.

Authors:  Ting Duan; Han-Yu Jiang; Wen-Wu Ling; Bin Song
Journal:  World J Gastroenterol       Date:  2022-04-28       Impact factor: 5.374

8.  Assessment of vascular stiffness in the internal carotid artery proximal to the carotid canal in Alzheimer's disease using pulse wave velocity from low rank reconstructed 4D flow MRI.

Authors:  Leonardo A Rivera-Rivera; Karly A Cody; Laura Eisenmenger; Paul Cary; Howard A Rowley; Cynthia M Carlsson; Sterling C Johnson; Kevin M Johnson
Journal:  J Cereb Blood Flow Metab       Date:  2020-03-13       Impact factor: 6.200

9.  Sildenafil administration improves right ventricular function on 4D flow MRI in young adults born premature.

Authors:  Philip A Corrado; Gregory P Barton; Christopher J Francois; Oliver Wieben; Kara N Goss
Journal:  Am J Physiol Heart Circ Physiol       Date:  2021-04-16       Impact factor: 5.125

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.