Literature DB >> 18956416

Quantitative 2D and 3D phase contrast MRI: optimized analysis of blood flow and vessel wall parameters.

A F Stalder1, M F Russe, A Frydrychowicz, J Bock, J Hennig, M Markl.   

Abstract

Quantification of CINE phase contrast (PC)-MRI data is a challenging task because of the limited spatiotemporal resolution and signal-to-noise ratio (SNR). The method presented in this work combines B-spline interpolation and Green's theorem to provide optimized quantification of blood flow and vessel wall parameters. The B-spline model provided optimal derivatives of the measured three-directional blood velocities onto the vessel contour, as required for vectorial wall shear stress (WSS) computation. Eight planes distributed along the entire thoracic aorta were evaluated in a 19-volunteer study using both high-spatiotemporal-resolution planar two-dimensional (2D)-CINE-PC ( approximately 1.4 x 1.4 mm(2)/24.4 ms) and lower-resolution 3D-CINE-PC ( approximately 2.8 x 1.6 x 3 mm(3)/48.6 ms) with three-directional velocity encoding. Synthetic data, error propagation, and interindividual, intermodality, and interobserver variability were used to evaluate the reliability and reproducibility of the method. While the impact of MR measurement noise was only minor, the limited resolution of PC-MRI introduced systematic WSS underestimations. In vivo data demonstrated close agreement for flow and WSS between 2D- and 3D-CINE-PC as well as observers, and confirmed the reliability of the method. WSS analysis along the aorta revealed the presence of a circumferential WSS component accounting for 10-20%. Initial results in a patient with atherosclerosis suggest the potential of the method for understanding the formation and progression of cardiovascular diseases.

Entities:  

Mesh:

Year:  2008        PMID: 18956416     DOI: 10.1002/mrm.21778

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  180 in total

1.  Synthetic dataset generation for the analysis and the evaluation of image-based hemodynamics of the human aorta.

Authors:  Umberto Morbiducci; Raffaele Ponzini; Giovanna Rizzo; Marco Evanghelos Biancolini; Francesco Iannaccone; Diego Gallo; Alberto Redaelli
Journal:  Med Biol Eng Comput       Date:  2011-12-23       Impact factor: 2.602

2.  In vivo and in vitro validation of aortic flow quantification by time-resolved three-dimensional velocity-encoded MRI.

Authors:  Fabian Rengier; Michael Delles; Roland Unterhinninghofen; Sebastian Ley; Matthias Müller-Eschner; Sasan Partovi; Philipp Geisbüsch; Rüdiger Dillmann; Hans-Ulrich Kauczor; Hendrik von Tengg-Kobligk
Journal:  Int J Cardiovasc Imaging       Date:  2012-02-24       Impact factor: 2.357

3.  Renal arteries: isotropic, high-spatial-resolution, unenhanced MR angiography with three-dimensional radial phase contrast.

Authors:  Christopher J François; Darren P Lum; Kevin M Johnson; Benjamin R Landgraf; Thorsten A Bley; Scott B Reeder; Mark L Schiebler; Thomas M Grist; Oliver Wieben
Journal:  Radiology       Date:  2010-10-27       Impact factor: 11.105

4.  Effects of arterial blood flow on walls of the abdominal aorta: distributions of wall shear stress and oscillatory shear index determined by phase-contrast magnetic resonance imaging.

Authors:  Koichi Sughimoto; Yoshiaki Shimamura; Chie Tezuka; Ken'ichi Tsubota; Hao Liu; Kenichiro Okumura; Yoshitada Masuda; Hideaki Haneishi
Journal:  Heart Vessels       Date:  2015-10-19       Impact factor: 2.037

5.  Four-dimensional flow MRI for evaluation of post-stenotic turbulent flow in a phantom: comparison with flowmeter and computational fluid dynamics.

Authors:  Jihoon Kweon; Dong Hyun Yang; Guk Bae Kim; Namkug Kim; MunYoung Paek; Aurelien F Stalder; Andreas Greiser; Young-Hak Kim
Journal:  Eur Radiol       Date:  2016-01-08       Impact factor: 5.315

6.  Characterizations and Correlations of Wall Shear Stress in Aneurysmal Flow.

Authors:  Amirhossein Arzani; Shawn C Shadden
Journal:  J Biomech Eng       Date:  2016-01       Impact factor: 2.097

Review 7.  Four-dimensional flow magnetic resonance imaging in cirrhosis.

Authors:  Zoran Stankovic
Journal:  World J Gastroenterol       Date:  2016-01-07       Impact factor: 5.742

8.  Comparison of 4D flow and 2D velocity-encoded phase contrast MRI sequences for the evaluation of aortic hemodynamics.

Authors:  Emilie Bollache; Pim van Ooij; Alex Powell; James Carr; Michael Markl; Alex J Barker
Journal:  Int J Cardiovasc Imaging       Date:  2016-07-19       Impact factor: 2.357

Review 9.  Noninvasive Imaging of Flow and Vascular Function in Disease of the Aorta.

Authors:  Matthew C Whitlock; W Gregory Hundley
Journal:  JACC Cardiovasc Imaging       Date:  2015-09

10.  Reproducibility of cerebrospinal venous blood flow and vessel anatomy with the use of phase contrast-vastly undersampled isotropic projection reconstruction and contrast-enhanced MRA.

Authors:  E M Schrauben; K M Johnson; J Huston; A M Del Rio; S B Reeder; A Field; O Wieben
Journal:  AJNR Am J Neuroradiol       Date:  2013-11-28       Impact factor: 3.825

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.