Goal-Directed Perfusion Methodology for Determining Oxygenator Performance during Clinical Cardiopulmonary Bypass.

Alfred H Stammers1, Randi Miller2, Stephen G Francis3, Laszlo Fuzesi4, Anthony Nostro5, Eric Tesdahl1.   

Abstract

New generation oxygenators incorporate arterial line filtration either sequential to, or directly in, the gas exchange module. This unique design may affect gas exchange performance by altering the operational characteristics of the device. The present study was designed to evaluate three oxygenators in a clinical setting using a goal-directed perfusion algorithm during cardiopulmonary bypass (CPB). After institutional review board approval, 60 adult patients undergoing cardiac surgery for acquired heart disease were matched for disease state and body size into three groups based on oxygenator type: Terumo SX18™ (n = 20), Terumo FX15™ (n = 20), and LivaNova Inspire6F™ 6 Dual (n = 20). An external arterial line filter was used with the FX15, whereas the SX18 and Inspire6F had integrated arterial filters. All perfusion, anesthetic and postoperative care management was standardized using institutional goal-directed patient management processes. Data were collected and stored according to quality improvement guidelines. There were no differences in demographics or type of surgical procedure performed among groups. The Inspire6F patients required lower fraction of inspired oxygen values as compared to the SX18 (67.9% ± 6.2% vs. 75.4% ± 6.5%, p < .005) and FX15 (79.1% ± 8.4%, p < .0001) groups. Arterial oxygen content and oxygen delivery were slightly higher in the FX15 group as compared to SX18 (13.1 ± 1.4 mL O2/dL vs. 12.4 ± 1.1 mL O2/dL, 611.1 ± 150.4 mL O2 vs. 528.2 ± 102.3 mL O2, p < .05). The FX15 patients had significantly higher CPB hematocrits compared to SX18 patients (30.3% ± 3.9% vs. 27.7% ± 2.6%, p < .05), but were not different when compared to the Inspire6F group (28.8% ± 3.5%, p < .50). There were no differences in intraoperative transfusion rates, but a higher percent of patients received postoperative transfusions in the SX18 group as compared to either FX15 or Inspire6F groups (p < .039). There were no differences in postoperative morbidity or complications in any group. In conclusion, the use of the SX18 was comparable to newer generation oxygenators in regard to gas exchange performance and the degree of hemodilution.

Entities:  

Keywords:  clinical study; gas transfer; outcomes; oxygenator; performance

Mesh:

Substances:

Year:  2017        PMID: 28638156      PMCID: PMC5474893     

Source DB:  PubMed          Journal:  J Extra Corpor Technol        ISSN: 0022-1058


  30 in total

1.  History of extracorporeal circulation: the invention and modification of blood pumps.

Authors:  Wolfgang Boettcher; Frank Merkle; Heinz-Hermann Weitkemper
Journal:  J Extra Corpor Technol       Date:  2003-09

2.  In vitro evaluation of gaseous microemboli handling of cardiopulmonary bypass circuits with and without integrated arterial line filters.

Authors:  Saifei Liu; Richard F Newland; Phillip J Tully; Sigrid C Tuble; Robert A Baker
Journal:  J Extra Corpor Technol       Date:  2011-09

3.  The effect of oxygenator mechanical characteristics on energy transfer during clinical cardiopulmonary bypass.

Authors:  Y M Ganushchak; K D Reesink; P W Weerwind; J G Maessen
Journal:  Perfusion       Date:  2010-10-04       Impact factor: 1.972

4.  Air Transmission Comparison of the Affinity Fusion Oxygenator with an Integrated Arterial Filter to the Affinity NT Oxygenator with a Separate Arterial Filter.

Authors:  Kieron C Potger; Darryl McMillan; Mark Ambrose
Journal:  J Extra Corpor Technol       Date:  2014-09

5.  Clinical evaluation of new generation oxygenators with integrated arterial line filters for cardiopulmonary bypass.

Authors:  Francesco Onorati; Francesco Santini; Federica Raffin; Tiziano Menon; Maria S Graziani; Bartolomeo Chiominto; Aldo Milano; Giuseppe Faggian; Alessandro Mazzucco
Journal:  Artif Organs       Date:  2012-07-16       Impact factor: 3.094

Review 6.  Does contemporary oxygenator design influence haemolysis?

Authors:  F De Somer
Journal:  Perfusion       Date:  2013-04-25       Impact factor: 1.972

7.  A retrospective comparison of blood transfusion requirements during cardiopulmonary bypass with two different small adult oxygenators.

Authors:  A Lahanas; P W Argerakis; K A Johnson; M L Burdan; J E Ozdirik
Journal:  Perfusion       Date:  2013-06-26       Impact factor: 1.972

8.  Use of computational fluid dynamics in the design of the Avecor Affinity oxygenator.

Authors:  M S Goodin; E J Thor; W S Haworth
Journal:  Perfusion       Date:  1994-05       Impact factor: 1.972

9.  Randomized trial of the Terumo Capiox FX05 oxygenator with integral arterial filter versus Terumo Capiox Baby RX05 and Terumo Capiox AF02 arterial filter in infants undergoing cardiopulmonary bypass.

Authors:  Mark M Nuszkowski; Nina Deutsch; Richard A Jonas; David Zurakowski; Erin Montague; David W Holt
Journal:  J Extra Corpor Technol       Date:  2011-12

10.  Evaluation of air handling in a new generation neonatal oxygenator with integral arterial filter.

Authors:  D Gomez; T J Preston; V F Olshove; A B Phillips; M E Galantowicz
Journal:  Perfusion       Date:  2009-03       Impact factor: 1.972

View more
  2 in total

1.  Does Standardizing Extracorporeal Circuit Design for Cardiopulmonary Bypass Affect Outcomes? Results from a National Perfusion Registry.

Authors:  Alfred H Stammers; Linda B Mongero; Eric A Tesdahl; Thomas Coley
Journal:  J Extra Corpor Technol       Date:  2019-12

2.  Pilot study of totally thoracoscopic periareolar approach for minimally invasive mitral valve surgery. Towards even less invasive?

Authors:  Marcin Maruszewski; Radosław Smoczyński; Mariusz Kowalewski; Maciej Bartczak; Anna Witkowska; Jakub Staromłyński; Dominik Drobiński; Mariusz Kujawski; Piotr Suwalski
Journal:  Wideochir Inne Tech Maloinwazyjne       Date:  2019-01-22       Impact factor: 1.195

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.