Literature DB >> 23804956

A retrospective comparison of blood transfusion requirements during cardiopulmonary bypass with two different small adult oxygenators.

A Lahanas1, P W Argerakis, K A Johnson, M L Burdan, J E Ozdirik.   

Abstract

A low haematocrit during cardiopulmonary bypass (CPB) is associated with adverse outcomes and often results in homologous blood transfusions. Oxygenators with improved venous reservoir designs aid in reducing the priming volume. Recently, we changed our small adult oxygenator model from the D905 EOS oxygenator (Dideco, Mirandola, Italy) to the Capiox FX1540 (Terumo Corporation, Tokyo, Japan). We conducted a retrospective study of 42 patents to evaluate the impact of the Capiox FX 1540 on blood transfusion requirements in small patients (body surface area (BSA) up to 1.8 m(2)). The D905 EOS group had a lower minimum intraoperative haematocrit than the FX1540 group (20 ± 3 v 22 ± 4, p = 0.029) with 73% of the patients receiving intraoperative blood transfusions compared with 30% in the FX 1540 group (p = 0.012). Patients in the D905 EOS group received one blood transfusion more during CPB than the FX 1540 patients (p = 0.002). The haematocrits at the end of CPB and in the early postoperative period were identical in both groups. The postoperative ventilation time, length of stay in the intensive care unit and postoperative chest drain bleeding were similar in both groups. In conclusion, the Capiox FX1540 was effective in reducing intraoperative packed red cell transfusions.

Entities:  

Keywords:  blood transfusion; cardiopulmonary bypass; oxygenator; priming volume; small adult

Mesh:

Year:  2013        PMID: 23804956     DOI: 10.1177/0267659113492835

Source DB:  PubMed          Journal:  Perfusion        ISSN: 0267-6591            Impact factor:   1.972


  3 in total

1.  Understanding Off-Label Use and Reference Blood Flows in Modern Membrane Oxygenators.

Authors:  Gerard J Myers
Journal:  J Extra Corpor Technol       Date:  2014-09

2.  Goal-Directed Perfusion Methodology for Determining Oxygenator Performance during Clinical Cardiopulmonary Bypass.

Authors:  Alfred H Stammers; Randi Miller; Stephen G Francis; Laszlo Fuzesi; Anthony Nostro; Eric Tesdahl
Journal:  J Extra Corpor Technol       Date:  2017-06

3.  Implementation of a Prescriptive Extracorporeal Circuit and Its Effect on Hemodilution and Blood Product Usage during Cardiac Surgery.

Authors:  Kelsie Kiser; Harleen Sandhu; Charles C Miller; David Holt
Journal:  J Extra Corpor Technol       Date:  2020-12