Literature DB >> 19654153

Evaluation of air handling in a new generation neonatal oxygenator with integral arterial filter.

D Gomez1, T J Preston, V F Olshove, A B Phillips, M E Galantowicz.   

Abstract

Prime volume of the cardiopulmonary bypass circuit may lead to significant hemodilution and the potential need for blood products for all patients, but may be more critical in the pediatric and, specifically, the neonatal patient. We report on the first use of the Terumo CAPIOX FX05 (Baby-FX) oxygenator with integral arterial filter, prime volume 43 ml, evaluating performance and air-handling of six Baby-FX versus thirteen Baby-RX oxygenators. The Terumo Baby-FX primes and performs as easily as the Baby-RX series. A significant prime component in the neonatal CPB circuit can be the arterial line filter (ALF). Removal of the ALF may lead to significant reduction in prime volume, decreased exposure to foreign surfaces with subsequent reduction in inflammation, and potential elimination or reduction in blood product exposures.

Entities:  

Mesh:

Year:  2009        PMID: 19654153     DOI: 10.1177/0267659109106825

Source DB:  PubMed          Journal:  Perfusion        ISSN: 0267-6591            Impact factor:   1.972


  9 in total

1.  In-vitro quantification of gaseous microemboli in two extracorporeal life support circuits.

Authors:  Jeffrey Burnside; Daniel Gomez; Thomas J Preston; Vincent F Olshove; Alistair Phillips
Journal:  J Extra Corpor Technol       Date:  2011-09

2.  Goal-Directed Perfusion Methodology for Determining Oxygenator Performance during Clinical Cardiopulmonary Bypass.

Authors:  Alfred H Stammers; Randi Miller; Stephen G Francis; Laszlo Fuzesi; Anthony Nostro; Eric Tesdahl
Journal:  J Extra Corpor Technol       Date:  2017-06

3.  The effects of pressure on gases in solution: possible insights to improve microbubble filtration for extracorporeal circulation.

Authors:  Daniel P Herbst
Journal:  J Extra Corpor Technol       Date:  2013-06

4.  Effects of Purge-Flow Rate on Microbubble Capture in Radial Arterial-Line Filters.

Authors:  Daniel P Herbst
Journal:  J Extra Corpor Technol       Date:  2016-09

5.  Can the oxygenator screen filter reduce gaseous microemboli?

Authors:  Daniel Johagen; Micael Appelblad; Staffan Svenmarker
Journal:  J Extra Corpor Technol       Date:  2014-03

6.  Removal of Gross Air Embolization from Cardiopulmonary Bypass Circuits with Integrated Arterial Line Filters: A Comparison of Circuit Designs.

Authors:  James A Reagor; David W Holt
Journal:  J Extra Corpor Technol       Date:  2016-03

7.  Randomized trial of the Terumo Capiox FX05 oxygenator with integral arterial filter versus Terumo Capiox Baby RX05 and Terumo Capiox AF02 arterial filter in infants undergoing cardiopulmonary bypass.

Authors:  Mark M Nuszkowski; Nina Deutsch; Richard A Jonas; David Zurakowski; Erin Montague; David W Holt
Journal:  J Extra Corpor Technol       Date:  2011-12

Review 8.  Recent innovations in perfusion and cardiopulmonary bypass for neonatal and infant cardiac surgery.

Authors:  David Sturmer; Claude Beaty; Sean Clingan; Eric Jenkins; Whitney Peters; Ming-Sing Si
Journal:  Transl Pediatr       Date:  2018-04

Review 9.  Evolution of membrane oxygenator technology for utilization during pediatric cardiopulmonary bypass.

Authors:  Richard W Melchior; Steven W Sutton; William Harris; Heidi J Dalton
Journal:  Pediatric Health Med Ther       Date:  2016-06-28
  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.