Literature DB >> 22803968

Clinical evaluation of new generation oxygenators with integrated arterial line filters for cardiopulmonary bypass.

Francesco Onorati1, Francesco Santini, Federica Raffin, Tiziano Menon, Maria S Graziani, Bartolomeo Chiominto, Aldo Milano, Giuseppe Faggian, Alessandro Mazzucco.   

Abstract

New generation oxygenators with integrated arterial line filters have been marketed to improve the efficacy of cardiopulmonary bypass (CPB). Differences in designs, materials, coating surfaces, pore size of arterial filter, and static prime exist between the oxygenators. Despite abundant preclinical data, literature lacks clinical studies. From September 2010 to March 2011, 80 consecutive patients were randomized to CPB using Terumo Capiox FX25 (40 patients, Group-T) or Sorin Synthesis (40 patients, Group-S) oxygenators. Pressure drop and gas exchange efficacy were registered during CPB. High-sensitivity C-reactive protein (hs-CRP), white blood cells (WBCs), fluid balance, activated clotting time, international normalized ratio (INR), activated partial thromboplastin time (aPTT), fibrinogen, platelets (PLTs), serum albumin, and total proteins were measured perioperatively at different timepoints. Clinical outcome was recorded. Repeated measure analysis of variance and nonparametric statistics assessed between-groups and during time differences. The two groups showed similar baseline and intraoperative variables. No differences were recorded in pressure drop and gas exchange (group-P and group*time-P = N.S. for all) during CPB. Despite similar fluid balance (P = N.S. for static/dynamic priming and ΔVolume administered intraoperatively), Group-T showed higher hs-CRP (group-P = 0.034), aPTT (group-P = 0.0001), and INR (group-P= 0.05), with lower serum albumin (group-P = 0.014), total proteins (group-P = 0.0001), fibrinogen (group-P = 0.041), and PLTs (group-P = 0.021). Group-T also showed higher postoperative bleeding (group-P = 0.009) and need for transfusions (P = 0.008 for packed red cells and P = 0.0001 for fresh frozen plasma and total transfused volumes). However, clinical outcome was comparable (P = N.S. for all clinical endpoints). Both oxygenators proved effective and resulted in comparable clinical outcomes. However, Sorin Synthesis seems to reduce inflammation and better preserve the coagulative cascade and serum proteins, resulting in lower transfusions and post-CPB inflammatory response.
© 2012, Copyright the Authors. Artificial Organs © 2012, International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22803968     DOI: 10.1111/j.1525-1594.2012.01469.x

Source DB:  PubMed          Journal:  Artif Organs        ISSN: 0160-564X            Impact factor:   3.094


  2 in total

1.  Goal-Directed Perfusion Methodology for Determining Oxygenator Performance during Clinical Cardiopulmonary Bypass.

Authors:  Alfred H Stammers; Randi Miller; Stephen G Francis; Laszlo Fuzesi; Anthony Nostro; Eric Tesdahl
Journal:  J Extra Corpor Technol       Date:  2017-06

2.  Effect of retrograde autologous priming based on miniaturized cardiopulmonary bypass in children undergoing open heart surgery: A STROBE compliant retrospective observational study.

Authors:  Baoying Meng; Keye Wu; Yuanxiang Wang; Sheshe Zhang; Xing Zhou; Yiqun Ding
Journal:  Medicine (Baltimore)       Date:  2020-01       Impact factor: 1.889

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.