| Literature DB >> 28634690 |
P Rogmark1,2, O Ekberg3,4, A Montgomery3,5.
Abstract
Purpose Ingrowth of fibroblasts in a polypropylene mesh may cause contraction and a later recurrence. We assessed mesh contraction in intraabdominal and retromuscular implantation after incisional hernia repair.Entities:
Keywords: IPOM; Incisional hernia repair; Mesh contraction; Retromuscular mesh
Mesh:
Substances:
Year: 2017 PMID: 28634690 PMCID: PMC5608776 DOI: 10.1007/s10029-017-1624-9
Source DB: PubMed Journal: Hernia ISSN: 1248-9204 Impact factor: 4.739
Characteristics of mesh size changes over time
| LHR ( |
| OHR ( |
| |||||
|---|---|---|---|---|---|---|---|---|
| Baseline | 1 year | Baseline | 1 year | |||||
| Hernia defect | ||||||||
| Length, cm | 9.0 | SD 5.4 | 7.6 | SD 5.8 |
| |||
| Width, cm | 6.1 | SD 2.8 | 4.6 | SD 2.4 |
| |||
| Area (mn SD), cm2 | 68 | SD 57 | 45 | SD 48 |
| |||
| Area (md IQR), cm2 | 41 | 18–104 | 25 | 6–86 |
| |||
| Mesh size | ||||||||
| Length (mn SD), cm | 15.9 | SD 4.7 | 15.4 SD 4.5 |
| 11.1 | SD 3.8 | 10.8 SD 3.5 |
|
| Width (mn SD), cm | 16.2 | SD 4.7 | 16.0 SD 3.5 |
| 12.3 | SD 2.5 | 12.6 SD 2.6 |
|
| Area, (mn SD), cm2 | 266 | SD 114 | 253 SD 109 |
| 143 | SD 68 | 142 SD 68 |
|
| Area (md IQR) cm2 | 253 | 157–389 | 239 145–366 | 240 | 175–412 | 131 83–195 | ||
| Mesh change % from start | ||||||||
| Length, mn% | −2.8 SE 1.15 |
| −2.6 SE 1.66 |
| ||||
| Width, mn% | −1.6 SE 1.21 |
| +3.13 SE 0.98 |
| ||||
| Mesh area, mn% | −4.4 SE 1.48 |
| +0.48 SE 2.16 |
| ||||
p < 0.05 are presented in bold
mn mean, SD standard deviation, md median, IQR interquartile range, SE standard error, LHR laparoscopic hernia repair, OHR open hernia repair
Fig. 1Abdominal supine examination after laparoscopic incisional hernia repair. The mesh is fixed with concentric rows of metal spiral tackers. The marker has a 10-mm hole and a 25 mm diameter. a Postoperative 1 day. b Postoperative 1 year
Fig. 2Abdominal supine examination after open incisional hernia repair. Mesh is placed in the retromuscular plane of the rectus abdominis muscles. Metal clips mark the longitudinal and transverse edges of the mesh and the hernia defect. The marker has a 10-mm hole and a 25 mm diameter. a Postoperative 1 day. b Postoperative 1 year
Pain assessment and correlation to mesh area change (MAC)
| LHR | OHR |
| |
|---|---|---|---|
| Preoperative | |||
| VAS (mm) | 2 (0–42) | 23 (0–32) |
|
| Follow-up | |||
| VAS (mm) | 0 (0–4) | 0 (0–2) |
|
| MAC | 0.109 ( | −0.208 ( | |
| Change | |||
| VAS (mm) | −2 (−34 to 0) | −14 (−32 to 0) | <0.662 |
| MAC | −0.209 ( | 0.025 ( | |
VAS values are median and interquartile range, r Pearson correlation coefficient
Review of mesh behavior in hernia repairs—study type and operative data
| References | Study |
| Mesh | Mesh material | Mesh position | Mesh fixation | Mesh overlap (cm) | Hernia defect (cm) |
|---|---|---|---|---|---|---|---|---|
| Ventral hernia studies | ||||||||
| Schoenmaeckers et al. [ | Retrospective | 40 | Dualmesh® | ePTFE | IPOM | Transfix + Protack® | – | – |
| Langer et al. [ | RCT mesh type | 27 | Biomesh® | • PP Hw | Retromusc. | PDS® | 5 | >4 |
| Beldi et al. [ | RCT mesh fixation | 36 | Parietene Composite® | PP | IPOM | • ProTack®
| 5 | <8 |
| Köhler et al. [ | Case report | 10 | Dynamesh IPOM® | PP/PVDF | IPOM | Transfix + Secure Straps® | 5 | – |
| Rogmark et al. [ | RCT op technique | 20 | Proceed®
| PP Lw | • IPOM | ProTack®
| 5 | <10 |
| Inguinal hernia studies | ||||||||
| Silvestre et al. [ | RCT mesh type | 15 | Prolene®
| • PP Hw | Licht:n | – | – | – |
| Ciritsis et al. [ | Case report | 10 | Dynamesh Endolap® | PVDF | TAPP | – | – | – |
| Summary | 4 RCT | 173 | 153 PP | 106 IPOM | ||||
ePTFE expanded polytetrafluoroethylene, PVDF polyvinylidene difluoride, PP polypropylene, Lw light weight, Hw heavy weight, • identifies group randomization
Review of mesh behavior in hernia repairs—mesh size change, dislocation, and recurrence
| Reference | Follow-up (months) | Follow-up modality | Mesh size change (%) | Dislocation | Recurrence | Comment | |
|---|---|---|---|---|---|---|---|
| Ventral hernia studies | |||||||
| Schoenmaeckers et al. [ | 18 | CT | Tv: | −7.5 ± 7.5 | – | 2 | Initial size from medical records |
| A: | −14 | ||||||
| Langer et al. [ | 12 | X-ray and CT | A: | Hw: +12 | – | 0 | Only transverse increase |
| Beldi et al. [ | 6 | X-ray | Vt: | t −2.8 SD 6.1 | 0 | 2 | More pain in suture group at 6 w: |
| Tv: | t −3.1 SD 3.9 | ||||||
| A: | t −2.5 | ||||||
| Köhler et al. [ | 3 | MRI | A: | −4.2 | – | – | 15 × 15 mesh implanted |
| Rogmark et al., [ | 12 | X-ray | Vt: | i −2.8 SD 1.15 | 5 | 3 | 5 dislocation in IPOM |
| Tv: | i −1.6 SD 1.21 | ||||||
| A: | i −4.4 SD 1.48 | ||||||
| Inguinal hernia studies | |||||||
| Silvestre et al. [ | 3 | X-ray | A: | Hw: −7.9 | – | 0 | |
| Ciritsis et al. [ | 3 | MRI | A: | −20.9 SD 7.1 | – | – | 7 patients, 3 bilateral operations |
| Average weighted size change | |||||||
| IPOM | Area: | −6.4 SD 6.4 | |||||
| Retromuscular (sublay) | Area: | +10.4 SD 6.1 | |||||
A area, Vt vertical, Tv transverse, Lw light weight, Hw heavy weight
Fig. 3Change of mesh measurements after 1 year relative to the immediate postoperative measurement. The horizontal black line is the mean change. Area defined as length × width