Literature DB >> 33919257

Accuracy of Computer-Assisted Dynamic Navigation in Implant Placement with a Fully Digital Approach: A Prospective Clinical Trial.

Cornelia Edelmann1, Martin Wetzel1, Anne Knipper1, Ralph G Luthardt2, Sigmar Schnutenhaus1,2.   

Abstract

BACKGROUND: This prospective clinical study aimed to investigate a possible deviation between the digitally planned implant position and the position achieved using dynamic navigation. The aim of the study was to establish clinical effectiveness and precision of implantation using dynamic navigation.
METHODS: Twenty consecutive patients received an implant (iSy-Implantat, Camlog, Wimsheim, Germany). One screw implant was placed in one jaw with remaining dentition of at least six teeth. The workflow was fully digital. Digital implant planning was conducted using cone-beam computed tomography (CBCT) and an intraoral scan of the actual condition. Twenty implants were subsequently placed using a dynamic computer-assisted procedure. The clinical situation of the implant position was recorded using an intraoral scan. Using these data, models were produced via 3D printing, and CBCTs of these models were made using laboratory analogs. Deviations of the achieved implant position from the planned position were determined using evaluation software.
RESULTS: The evaluation of 20 implants resulted in a mean angle deviation of 2.7° (95% CI 2.2-3.3°). The 3D deviation at the implant shoulder was 1.83 mm (95% CI 1.34-2.33 mm). No significant differences were found for any of the parameters between the implantation in the upper or lower jaw and an open or flapless procedure (p-value < 0.05).
CONCLUSION: The clinical trial showed that sufficiently precise implantation was possible with the dynamic navigation system used here. Dynamic navigation can improve the quality of implant positioning. In particular, the procedure allows safe positioning of the implants in minimally invasive procedures, which usually cannot be performed freehand in this form. A clinical benefit and effectiveness can be determined from the results.

Entities:  

Keywords:  computer-aided surgery; computer-assisted surgery; dental implants; dynamic navigation; real-time tracking

Year:  2021        PMID: 33919257     DOI: 10.3390/jcm10091808

Source DB:  PubMed          Journal:  J Clin Med        ISSN: 2077-0383            Impact factor:   4.241


  42 in total

Review 1.  Computer technology applications in surgical implant dentistry: a systematic review.

Authors:  Ronald E Jung; David Schneider; Jeffrey Ganeles; Daniel Wismeijer; Marcel Zwahlen; Christoph H F Hämmerle; Ali Tahmaseb
Journal:  Int J Oral Maxillofac Implants       Date:  2009       Impact factor: 2.804

2.  The accuracy of static vs. dynamic computer-assisted implant surgery in single tooth space: A randomized controlled trial.

Authors:  Dechawat Kaewsiri; Soontra Panmekiate; Keskanya Subbalekha; Nikos Mattheos; Atiphan Pimkhaokham
Journal:  Clin Oral Implants Res       Date:  2019-05-07       Impact factor: 5.977

Review 3.  Accuracy of Implant Placement with Computer-Guided Surgery: A Systematic Review and Meta-Analysis Comparing Cadaver, Clinical, and In Vitro Studies.

Authors:  Fernando Bover-Ramos; José Viña-Almunia; Juan Cervera-Ballester; Miguel Peñarrocha-Diago; Berta García-Mira
Journal:  Int J Oral Maxillofac Implants       Date:  2017-06-20       Impact factor: 2.804

4.  The accuracy of static computer-aided implant surgery: A systematic review and meta-analysis.

Authors:  Ali Tahmaseb; Viviane Wu; Daniel Wismeijer; Wim Coucke; Christopher Evans
Journal:  Clin Oral Implants Res       Date:  2018-10       Impact factor: 5.977

Review 5.  Different techniques of static/dynamic guided implant surgery: modalities and indications.

Authors:  Marjolein Vercruyssen; Thomas Fortin; Gerlig Widmann; Reinhilde Jacobs; Marc Quirynen
Journal:  Periodontol 2000       Date:  2014-10       Impact factor: 7.589

Review 6.  Initial and long-term crestal bone responses to modern dental implants.

Authors:  Tomas Albrektsson; Bruno Chrcanovic; Per-Olov Östman; Lars Sennerby
Journal:  Periodontol 2000       Date:  2017-02       Impact factor: 7.589

Review 7.  Osseointegration of titanium, titanium alloy and zirconia dental implants: current knowledge and open questions.

Authors:  Dieter D Bosshardt; Vivianne Chappuis; Daniel Buser
Journal:  Periodontol 2000       Date:  2017-02       Impact factor: 7.589

8.  Accuracy and precision of 3D-printed implant surgical guides with different implant systems: An in vitro study.

Authors:  Matthew Yeung; Aous Abdulmajeed; Caroline K Carrico; George R Deeb; Sompop Bencharit
Journal:  J Prosthet Dent       Date:  2019-10-23       Impact factor: 3.426

9.  Quantification of image artifacts from navigation markers in dynamic guided implant surgery and the effect on registration performance in different clinical scenarios.

Authors:  Yu Du; Kaijuan Wangrao; Liu Liu; Li Liu; Yang Yao
Journal:  Int J Oral Maxillofac Implants       Date:  2018-12-05       Impact factor: 2.804

10.  Accuracy of Computer-Aided Dynamic Navigation Compared to Computer-Aided Static Navigation for Dental Implant Placement: An In Vitro Study.

Authors:  Alfonso Mediavilla Guzmán; Elena Riad Deglow; Álvaro Zubizarreta-Macho; Rubén Agustín-Panadero; Sofía Hernández Montero
Journal:  J Clin Med       Date:  2019-12-02       Impact factor: 4.241

View more
  2 in total

1.  Clinical and radiological outcomes of novel digital workflow and dynamic navigation for single-implant immediate loading in aesthetic zone: 1-year prospective case series.

Authors:  Alessandro Pozzi; Lorenzo Arcuri; Paolo Carosi; Alessandra Nardi; Joseph Kan
Journal:  Clin Oral Implants Res       Date:  2021-09-08       Impact factor: 5.021

2.  Dynamic navigation system-guided trans-inferior alveolar nerve implant placement in the atrophic posterior mandible: A case report.

Authors:  Liang-Wen Chen; Xiao-E Zhao; Qi Yan; Hai-Bin Xia; Quan Sun
Journal:  World J Clin Cases       Date:  2022-04-26       Impact factor: 1.534

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.