Literature DB >> 28585878

Practical Considerations on the Use of Continuous Glucose Monitoring in Pediatrics and Older Adults and Nonadjunctive Use.

Gregory P Forlenza1, Nicholas B Argento2, Lori M Laffel3.   

Abstract

Clinical use of continuous glucose monitoring (CGM) devices has grown over the past 15 years from a niche concept to becoming standard of care for patients with type 1 diabetes (T1D). With the December 2016 Food and Drug Administration approval for diabetes treatment decisions directly from CGM values (nonadjunctive use) without finger-stick confirmation, the uptake and scope of CGM use will likely further expand. With this expansion, it is important to consider the role and impact of CGM technology in specific settings and high-risk populations, such as the young and the elderly. In pediatric patients, CGM concerns include limited body surface area, difficulty keeping sensors adhered, and the role of nonadjunctive use in the school setting. In older adults, Medicare did not, until very recently, cover CGM devices and as such, their use had been limited by lack of reimbursement. As CGM use will likely expand in clinical practice given the nonadjunctive indication, guidelines and recommendations for clinical practice are warranted. In this article, we discuss recent research on CGM use in the special populations of children and older adults and provide initial guidelines for nonadjunctive use in clinical practice.

Entities:  

Keywords:  Continuous glucose monitoring; Nonadjunctive use; Type 1 diabetes.

Mesh:

Substances:

Year:  2017        PMID: 28585878      PMCID: PMC5467117          DOI: 10.1089/dia.2017.0034

Source DB:  PubMed          Journal:  Diabetes Technol Ther        ISSN: 1520-9156            Impact factor:   6.118


  43 in total

1.  Management of Type 1 Diabetes in Older Adults.

Authors:  Ruban Dhaliwal; Ruth S Weinstock
Journal:  Diabetes Spectr       Date:  2014-02

2.  Current state of type 1 diabetes treatment in the U.S.: updated data from the T1D Exchange clinic registry.

Authors:  Kellee M Miller; Nicole C Foster; Roy W Beck; Richard M Bergenstal; Stephanie N DuBose; Linda A DiMeglio; David M Maahs; William V Tamborlane
Journal:  Diabetes Care       Date:  2015-06       Impact factor: 19.112

3.  Mortality in Type 1 Diabetes in the DCCT/EDIC Versus the General Population.

Authors: 
Journal:  Diabetes Care       Date:  2016-07-13       Impact factor: 19.112

4.  Momentary assessment of social context and glucose monitoring adherence in adolescents with type 1 diabetes.

Authors:  Joshua S Borus; Emily Blood; Lisa K Volkening; Lori Laffel; Lydia A Shrier
Journal:  J Adolesc Health       Date:  2012-12-12       Impact factor: 5.012

5.  Multiple complications and frequent severe hypoglycaemia in 'elderly' and 'old' patients with Type 1 diabetes.

Authors:  M Schütt; E-M Fach; J Seufert; W Kerner; W Lang; A Zeyfang; R Welp; R W Holl
Journal:  Diabet Med       Date:  2012-08       Impact factor: 4.359

6.  Insulin Pump and CGM Usage in the United States and Germany: Results of a Real-World Survey With 985 Subjects.

Authors:  John Walsh; Ruth Roberts; Dietmar Weber; Gabriele Faber-Heinemann; Lutz Heinemann
Journal:  J Diabetes Sci Technol       Date:  2015-06-12

7.  Effect of Continuous Glucose Monitoring on Glycemic Control in Adults With Type 1 Diabetes Using Insulin Injections: The DIAMOND Randomized Clinical Trial.

Authors:  Roy W Beck; Tonya Riddlesworth; Katrina Ruedy; Andrew Ahmann; Richard Bergenstal; Stacie Haller; Craig Kollman; Davida Kruger; Janet B McGill; William Polonsky; Elena Toschi; Howard Wolpert; David Price
Journal:  JAMA       Date:  2017-01-24       Impact factor: 56.272

8.  Analysis of a remote system to closely monitor glycemia and insulin pump delivery--is this the beginning of a wireless transformation in diabetes management?

Authors:  Eda Cengiz
Journal:  J Diabetes Sci Technol       Date:  2013-03-01

9.  Continuous glucose monitoring and intensive treatment of type 1 diabetes.

Authors:  William V Tamborlane; Roy W Beck; Bruce W Bode; Bruce Buckingham; H Peter Chase; Robert Clemons; Rosanna Fiallo-Scharer; Larry A Fox; Lisa K Gilliam; Irl B Hirsch; Elbert S Huang; Craig Kollman; Aaron J Kowalski; Lori Laffel; Jean M Lawrence; Joyce Lee; Nelly Mauras; Michael O'Grady; Katrina J Ruedy; Michael Tansey; Eva Tsalikian; Stuart Weinzimer; Darrell M Wilson; Howard Wolpert; Tim Wysocki; Dongyuan Xing
Journal:  N Engl J Med       Date:  2008-09-08       Impact factor: 91.245

10.  Effect of acetaminophen on CGM glucose in an outpatient setting.

Authors:  David M Maahs; Daniel DeSalvo; Laura Pyle; Trang Ly; Laurel Messer; Paula Clinton; Emily Westfall; R Paul Wadwa; Bruce Buckingham
Journal:  Diabetes Care       Date:  2015-08-12       Impact factor: 19.112

View more
  19 in total

Review 1.  Use of Diabetes Technology in Children: Role of Structured Education for Young People with Diabetes and Families.

Authors:  Hannah R Desrochers; Alan T Schultz; Lori M Laffel
Journal:  Endocrinol Metab Clin North Am       Date:  2020-03       Impact factor: 4.741

2.  The Future of Continuous Glucose Monitoring.

Authors:  Satish K Garg; Halis K Akturk
Journal:  Diabetes Technol Ther       Date:  2017-06       Impact factor: 6.118

3.  Safety and Accuracy of Factory-Calibrated Continuous Glucose Monitoring in Pediatric Patients Undergoing Hematopoietic Stem Cell Transplantation.

Authors:  Jenna Sopfe; Tim Vigers; Laura Pyle; Roger H Giller; Gregory P Forlenza
Journal:  Diabetes Technol Ther       Date:  2020-03-17       Impact factor: 6.118

4.  Perceived Usefulness of Continuous Glucose Monitoring Devices at the Workplace: Secondary Analysis of Data From a Qualitative Study.

Authors:  Jessica Scharf; Xuan Quynh Nguyen; Patricia Vu-Eickmann; Michael Krichbaum; Adrian Loerbroks
Journal:  J Diabetes Sci Technol       Date:  2018-07-20

5.  Continuous Glucose Monitoring: Current Use in Diabetes Management and Possible Future Applications.

Authors:  Martina Vettoretti; Giacomo Cappon; Giada Acciaroli; Andrea Facchinetti; Giovanni Sparacino
Journal:  J Diabetes Sci Technol       Date:  2018-05-22

6.  Preserving Skin Integrity with Chronic Device Use in Diabetes.

Authors:  Laurel H Messer; Cari Berget; Christie Beatson; Sarit Polsky; Gregory P Forlenza
Journal:  Diabetes Technol Ther       Date:  2018-06       Impact factor: 6.118

7.  Accuracy of a 14-Day Factory-Calibrated Continuous Glucose Monitoring System With Advanced Algorithm in Pediatric and Adult Population With Diabetes.

Authors:  Shridhara Alva; Timothy Bailey; Ronald Brazg; Erwin S Budiman; Kristin Castorino; Mark P Christiansen; Gregory Forlenza; Mark Kipnes; David R Liljenquist; Hanqing Liu
Journal:  J Diabetes Sci Technol       Date:  2020-09-19

8.  Help when you need it: Perspectives of adults with T1D on the support and training they would have wanted when starting CGM.

Authors:  Molly L Tanenbaum; Laurel H Messer; Christine A Wu; Marina Basina; Bruce A Buckingham; Danielle Hessler; Shelagh A Mulvaney; David M Maahs; Korey K Hood
Journal:  Diabetes Res Clin Pract       Date:  2021-09-14       Impact factor: 8.180

9.  Pediatric Medicaid Patients With Type 1 Diabetes Benefit From Continuous Glucose Monitor Technology.

Authors:  Sonalee J Ravi; Alexander Coakley; Tim Vigers; Laura Pyle; Gregory P Forlenza; Todd Alonso
Journal:  J Diabetes Sci Technol       Date:  2020-03-14

10.  Perspectives on Remote Glucose Monitoring in Youth With Type 1 Diabetes.

Authors:  Ettya R Fremont; Victoria A Miller
Journal:  J Pediatr Psychol       Date:  2021-10-18
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.