Literature DB >> 30027749

Perceived Usefulness of Continuous Glucose Monitoring Devices at the Workplace: Secondary Analysis of Data From a Qualitative Study.

Jessica Scharf1, Xuan Quynh Nguyen1, Patricia Vu-Eickmann1, Michael Krichbaum2, Adrian Loerbroks1.   

Abstract

BACKGROUND: Previous research suggests that psychosocial working conditions may detrimentally affect diabetes self-management behavior at work, including self-monitoring of glucose levels. We aimed to better understand the potential usefulness of continuous glucose monitoring devices at the workplace according to employees with diabetes.
METHODS: We carried out secondary analyses of data from a qualitative study, which sought to explore potential barriers to and solutions for effective diabetes self-management at work. Interviews were carried out in face-to-face contact or by telephone and were transcribed and content-analyzed using MaxQDA. The used topic guide did not specifically inquire after continuous glucose monitoring devices, but views on the suitability of those devices at the workplace repeatedly emerged from the interviews. Data from 25 employed adults with diabetes mellitus type 1 or type 2 on insulin therapy were included.
RESULTS: The major perceived improvements associated with the use of continuous glucose monitoring devices pertained to their time-saving application that allowed for an increased frequency of glucose level assessments and for socially covert glucose measurement. The socially less noticeable way of monitoring glucose level was specifically perceived as beneficial, as employees with diabetes believed their illness would thereby attract less attention. Fewer or shorter interruptions as well as the reliability of integrated alarm systems were perceived to increase concentration at work and workability.
CONCLUSIONS: Continuous glucose monitoring devices were perceived to facilitate glucose management at the workplace, which may exert positive effects on compliance as well as functioning at work. Further research would be of interest to statistically confirm our findings in occupational samples.

Entities:  

Keywords:  continuous glucose monitoring; diabetes mellitus; qualitative study; workplace

Mesh:

Substances:

Year:  2018        PMID: 30027749      PMCID: PMC6399790          DOI: 10.1177/1932296818789143

Source DB:  PubMed          Journal:  J Diabetes Sci Technol        ISSN: 1932-2968


  20 in total

1.  The role of work-related and personal factors in diabetes self-management.

Authors:  Iris Weijman; Wynand J G Ros; Guy E H M Rutten; Wilmar B Schaufeli; Marc J Schabracq; Jacques A M Winnubst
Journal:  Patient Educ Couns       Date:  2005-10

2.  Novel glucose-sensing technology and hypoglycaemia in type 1 diabetes: a multicentre, non-masked, randomised controlled trial.

Authors:  Jan Bolinder; Ramiro Antuna; Petronella Geelhoed-Duijvestijn; Jens Kröger; Raimund Weitgasser
Journal:  Lancet       Date:  2016-09-12       Impact factor: 79.321

3.  Best friend or spy: a qualitative meta-synthesis on the impact of continuous glucose monitoring on life with Type 1 diabetes.

Authors:  L H Messer; R Johnson; K A Driscoll; J Jones
Journal:  Diabet Med       Date:  2017-12-27       Impact factor: 4.359

4.  Disclosure of Type 1 diabetes at work among Finnish workers.

Authors:  P Hakkarainen; L Moilanen; V Hänninen; K Räsänen; F Munir
Journal:  Diabet Med       Date:  2016-05-27       Impact factor: 4.359

Review 5.  Psychosocial Aspects of Continuous Glucose Monitoring: Connecting to the Patients' Experience.

Authors:  Thomas Kubiak; Caroline G Mann; Katherine C Barnard; Lutz Heinemann
Journal:  J Diabetes Sci Technol       Date:  2016-06-28

6.  Characteristics associated with non-disclosure of Type 2 diabetes at work.

Authors:  K Olesen; B Cleal; T Skinner; I Willaing
Journal:  Diabet Med       Date:  2017-06-06       Impact factor: 4.359

7.  CGM Versus FGM; or, Continuous Glucose Monitoring Is Not Flash Glucose Monitoring.

Authors:  Lutz Heinemann; Guido Freckmann
Journal:  J Diabetes Sci Technol       Date:  2015-09-01

8.  Effect of Continuous Glucose Monitoring on Glycemic Control, Acute Admissions, and Quality of Life: A Real-World Study.

Authors:  Sara Charleer; Chantal Mathieu; Frank Nobels; Christophe De Block; Regis P Radermecker; Michel P Hermans; Youri Taes; Chris Vercammen; Guy T'Sjoen; Laurent Crenier; Steffen Fieuws; Bart Keymeulen; Pieter Gillard
Journal:  J Clin Endocrinol Metab       Date:  2018-03-01       Impact factor: 5.958

9.  The Performance and Usability of a Factory-Calibrated Flash Glucose Monitoring System.

Authors:  Timothy Bailey; Bruce W Bode; Mark P Christiansen; Leslie J Klaff; Shridhara Alva
Journal:  Diabetes Technol Ther       Date:  2015-07-14       Impact factor: 6.118

10.  Performance of the FreeStyle Libre Flash glucose monitoring system in patients with type 1 and 2 diabetes mellitus.

Authors:  M J Fokkert; P R van Dijk; M A Edens; S Abbes; D de Jong; R J Slingerland; H J G Bilo
Journal:  BMJ Open Diabetes Res Care       Date:  2017-02-17
View more
  2 in total

1.  Work-Related Intervention Needs of Medical Assistants and How to Potentially Address Them according to Supervising General Practitioners: A Qualitative Study.

Authors:  Jessica Scharf; Patricia Vu-Eickmann; Peter Angerer; Andreas Müller; Jürgen In der Schmitten; Adrian Loerbroks
Journal:  Int J Environ Res Public Health       Date:  2022-01-26       Impact factor: 3.390

2.  Return to Work after Common Mental Disorders: A Qualitative Study Exploring the Expectations of the Involved Stakeholders.

Authors:  Jessica Scharf; Peter Angerer; Gesine Müting; Adrian Loerbroks
Journal:  Int J Environ Res Public Health       Date:  2020-09-11       Impact factor: 3.390

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.