Literature DB >> 28580460

State Estimation with Sensor Recalibrations and Asynchronous Measurements for MPC of an Artificial Pancreas to Treat T1DM.

Ravi Gondhalekar1, Eyal Dassau1, Francis J Doyle1.   

Abstract

A novel state estimation scheme is proposed for use in Model Predictive Control (MPC) of an artificial pancreas based on Continuous Glucose Monitor (CGM) feedback, for treating type 1 diabetes mellitus. The performance of MPC strategies heavily depends on the initial condition of the predictions, typically characterized by a state estimator. Commonly employed Luenberger-observers and Kalman-filters are effective much of the time, but suffer limitations. Three particular limitations are tackled by the proposed approach. First, CGM recalibrations, step changes that cause highly dynamic responses in recursive state estimators, are accommodated in a graceful manner. Second, the proposed strategy is not affected by CGM measurements that are asynchronous, i.e., neither of fixed sample-period, nor of a sample-period that is equal to the controller's. Third, the proposal suffers no offsets due to plant-model mismatches. The proposed approach is based on moving-horizon optimization.

Entities:  

Keywords:  Artificial pancreas; Model predictive control; Optimization; State estimation

Year:  2014        PMID: 28580460      PMCID: PMC5451162          DOI: 10.3182/20140824-6-ZA-1003.01085

Source DB:  PubMed          Journal:  Proc IFAC World Congress


  17 in total

1.  Clinical hurdles and possible solutions in the implementation of closed-loop control in type 1 diabetes mellitus.

Authors:  Howard Zisser
Journal:  J Diabetes Sci Technol       Date:  2011-09-01

2.  A dual-rate Kalman filter for continuous glucose monitoring.

Authors:  Matthew Kuure-Kinsey; Cesar C Palerm; B Wayne Bequette
Journal:  Conf Proc IEEE Eng Med Biol Soc       Date:  2006

3.  Use of fourier models for analysis and interpretation of continuous glucose monitoring glucose profiles.

Authors:  Michael Miller; Poul Strange
Journal:  J Diabetes Sci Technol       Date:  2007-09

4.  A model-based algorithm for blood glucose control in type I diabetic patients.

Authors:  R S Parker; F J Doyle; N A Peppas
Journal:  IEEE Trans Biomed Eng       Date:  1999-02       Impact factor: 4.538

5.  Multivariable adaptive closed-loop control of an artificial pancreas without meal and activity announcement.

Authors:  Kamuran Turksoy; Elif Seyma Bayrak; Lauretta Quinn; Elizabeth Littlejohn; Ali Cinar
Journal:  Diabetes Technol Ther       Date:  2013-04-01       Impact factor: 6.118

6.  Fully integrated artificial pancreas in type 1 diabetes: modular closed-loop glucose control maintains near normoglycemia.

Authors:  Marc Breton; Anne Farret; Daniela Bruttomesso; Stacey Anderson; Lalo Magni; Stephen Patek; Chiara Dalla Man; Jerome Place; Susan Demartini; Simone Del Favero; Chiara Toffanin; Colleen Hughes-Karvetski; Eyal Dassau; Howard Zisser; Francis J Doyle; Giuseppe De Nicolao; Angelo Avogaro; Claudio Cobelli; Eric Renard; Boris Kovatchev
Journal:  Diabetes       Date:  2012-06-11       Impact factor: 9.461

7.  Quest for the artificial pancreas: combining technology with treatment.

Authors:  Rebecca A Harvey; Youqing Wang; Benyamin Grosman; Matthew W Percival; Wendy Bevier; Daniel A Finan; Howard Zisser; Dale E Seborg; Lois Jovanovic; Francis J Doyle; Eyal Dassau
Journal:  IEEE Eng Med Biol Mag       Date:  2010 Mar-Apr

8.  Zone model predictive control: a strategy to minimize hyper- and hypoglycemic events.

Authors:  Benyamin Grosman; Eyal Dassau; Howard C Zisser; Lois Jovanovic; Francis J Doyle
Journal:  J Diabetes Sci Technol       Date:  2010-07-01

9.  Model predictive control of type 1 diabetes: an in silico trial.

Authors:  Lalo Magni; Davide M Raimondo; Luca Bossi; Chiara Dalla Man; Giuseppe De Nicolao; Boris Kovatchev; Claudio Cobelli
Journal:  J Diabetes Sci Technol       Date:  2007-11

Review 10.  Artificial pancreas: past, present, future.

Authors:  Claudio Cobelli; Eric Renard; Boris Kovatchev
Journal:  Diabetes       Date:  2011-11       Impact factor: 9.461

View more
  2 in total

1.  Moving-horizon-like state estimation via continuous glucose monitor feedback in MPC of an artificial pancreas for type 1 diabetes.

Authors:  Ravi Gondhalekar; Eyal Dassau; Francis J Doyle
Journal:  Proc IEEE Conf Decis Control       Date:  2015-02-12

2.  Velocity-weighting & velocity-penalty MPC of an artificial pancreas: Improved safety & performance.

Authors:  Ravi Gondhalekar; Eyal Dassau; Francis J Doyle
Journal:  Automatica (Oxf)       Date:  2018-03-20       Impact factor: 5.944

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.