Literature DB >> 19885152

Model predictive control of type 1 diabetes: an in silico trial.

Lalo Magni1, Davide M Raimondo, Luca Bossi, Chiara Dalla Man, Giuseppe De Nicolao, Boris Kovatchev, Claudio Cobelli.   

Abstract

BACKGROUND: The development of artificial pancreas has received a new impulse from recent technological advancements in subcutaneous continuous glucose monitoring and subcutaneous insulin pump delivery systems. However, the availability of innovative sensors and actuators, although essential, does not guarantee optimal glycemic regulation. Closed-loop control of blood glucose levels still poses technological challenges to the automatic control expert, most notable of which are the inevitable time delays between glucose sensing and insulin actuation.
METHODS: A new in silico model is exploited for both design and validation of a linear model predictive control (MPC) glucose control system. The starting point is a recently developed meal glucose-insulin model in health, which is modified to describe the metabolic dynamics of a person with type 1 diabetes mellitus. The population distribution of the model parameters originally obtained in healthy 204 patients is modified to describe diabetic patients. Individual models of virtual patients are extracted from this distribution. A discrete-time MPC is designed for all the virtual patients from a unique input-output-linearized approximation of the full model based on the average population values of the parameters. The in silico trial simulates 4 consecutive days, during which the patient receives breakfast, lunch, and dinner each day.
RESULTS: Provided that the regulator undergoes some individual tuning, satisfactory results are obtained even if the control design relies solely on the average patient model. Only the weight on the glucose concentration error needs to be tuned in a quite straightforward and intuitive way. The ability of the MPC to take advantage of meal announcement information is demonstrated. Imperfect knowledge of the amount of ingested glucose causes only marginal deterioration of performance. In general, MPC results in better regulation than proportional integral derivative, limiting significantly the oscillation of glucose levels.
CONCLUSIONS: The proposed in silico trial shows the potential of MPC for artificial pancreas design. The main features are a capability to consider meal announcement information, delay compensation, and simplicity of tuning and implementation.

Entities:  

Keywords:  artificial pancreas; diabetes; model predictive control; simulation; virtual patients

Year:  2007        PMID: 19885152      PMCID: PMC2769684          DOI: 10.1177/193229680700100603

Source DB:  PubMed          Journal:  J Diabetes Sci Technol        ISSN: 1932-2968


  12 in total

1.  Oral glucose tolerance test minimal model indexes of beta-cell function and insulin sensitivity.

Authors:  E Breda; M K Cavaghan; G Toffolo; K S Polonsky; C Cobelli
Journal:  Diabetes       Date:  2001-01       Impact factor: 9.461

2.  A model of glucose production during a meal.

Authors:  Chiara Dalla Man; Gianna Toffolo; Rita Basu; Robert A Rizza; Claudio Cobelli
Journal:  Conf Proc IEEE Eng Med Biol Soc       Date:  2006

3.  The hot IVGTT two-compartment minimal model: indexes of glucose effectiveness and insulin sensitivity.

Authors:  P Vicini; A Caumo; C Cobelli
Journal:  Am J Physiol       Date:  1997-11

4.  A model-based algorithm for blood glucose control in type I diabetic patients.

Authors:  R S Parker; F J Doyle; N A Peppas
Journal:  IEEE Trans Biomed Eng       Date:  1999-02       Impact factor: 4.538

5.  Model-based blood glucose control for Type 1 diabetes via parametric programming.

Authors:  Pinky Dua; Francis J Doyle; Efstratios N Pistikopoulos
Journal:  IEEE Trans Biomed Eng       Date:  2006-08       Impact factor: 4.538

6.  Quantifying temporal glucose variability in diabetes via continuous glucose monitoring: mathematical methods and clinical application.

Authors:  Boris P Kovatchev; William L Clarke; Marc Breton; Kenneth Brayman; Anthony McCall
Journal:  Diabetes Technol Ther       Date:  2005-12       Impact factor: 6.118

7.  A system model of oral glucose absorption: validation on gold standard data.

Authors:  Chiara Dalla Man; Michael Camilleri; Claudio Cobelli
Journal:  IEEE Trans Biomed Eng       Date:  2006-12       Impact factor: 4.538

8.  The artificial pancreas: how sweet engineering will solve bitter problems.

Authors:  David C Klonoff
Journal:  J Diabetes Sci Technol       Date:  2007-01

9.  Meal simulation model of the glucose-insulin system.

Authors:  Chiara Dalla Man; Robert A Rizza; Claudio Cobelli
Journal:  IEEE Trans Biomed Eng       Date:  2007-10       Impact factor: 4.538

10.  Effects of plasma glucose concentration on glucose utilization and glucose clearance in normal man.

Authors:  C A Verdonk; R A Rizza; J E Gerich
Journal:  Diabetes       Date:  1981-06       Impact factor: 9.461

View more
  77 in total

1.  Development of a multi-parametric model predictive control algorithm for insulin delivery in type 1 diabetes mellitus using clinical parameters.

Authors:  M W Percival; Y Wang; B Grosman; E Dassau; H Zisser; L Jovanovič; F J Doyle
Journal:  J Process Control       Date:  2011-03-01       Impact factor: 3.666

2.  AP@home: a novel European approach to bring the artificial pancreas home.

Authors:  Lutz Heinemann; Carsten Benesch; J Hans DeVries
Journal:  J Diabetes Sci Technol       Date:  2011-11-01

3.  Impact of blood glucose self-monitoring errors on glucose variability, risk for hypoglycemia, and average glucose control in type 1 diabetes: an in silico study.

Authors:  Marc D Breton; Boris P Kovatchev
Journal:  J Diabetes Sci Technol       Date:  2010-05-01

4.  A simplification of Cobelli's glucose-insulin model for type 1 diabetes mellitus and its FPGA implementation.

Authors:  Peng Li; Lei Yu; Qiang Fang; Shuenn-Yuh Lee
Journal:  Med Biol Eng Comput       Date:  2015-12-30       Impact factor: 2.602

Review 5.  Can technological solutions for diabetes replace islet cell function?

Authors:  Justin M Gregory; Daniel J Moore
Journal:  Organogenesis       Date:  2011-01-01       Impact factor: 2.500

6.  Modeling the error of continuous glucose monitoring sensor data: critical aspects discussed through simulation studies.

Authors:  Andrea Facchinetti; Giovanni Sparacino; Claudio Cobelli
Journal:  J Diabetes Sci Technol       Date:  2010-01-01

7.  Algorithms for a closed-loop artificial pancreas: the case for model predictive control.

Authors:  B Wayne Bequette
Journal:  J Diabetes Sci Technol       Date:  2013-11-01

8.  Postprandial fuzzy adaptive strategy for a hybrid proportional derivative controller for the artificial pancreas.

Authors:  Aleix Beneyto; Josep Vehi
Journal:  Med Biol Eng Comput       Date:  2018-05-03       Impact factor: 2.602

9.  Multi-level Supervision and Modification of Artificial Pancreas Control System.

Authors:  Jianyuan Feng; Iman Hajizadeh; Xia Yu; Mudassir Rashid; Kamuran Turksoy; Sediqeh Samadi; Mert Sevil; Nicole Hobbs; Rachel Brandt; Caterina Lazaro; Zacharie Maloney; Elizabeth Littlejohn; Louis H Philipson; Ali Cinar
Journal:  Comput Chem Eng       Date:  2018-02-10       Impact factor: 3.845

10.  In silico preclinical trials: a proof of concept in closed-loop control of type 1 diabetes.

Authors:  Boris P Kovatchev; Marc Breton; Chiara Dalla Man; Claudio Cobelli
Journal:  J Diabetes Sci Technol       Date:  2009-01
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.