Literature DB >> 9932336

A model-based algorithm for blood glucose control in type I diabetic patients.

R S Parker1, F J Doyle, N A Peppas.   

Abstract

A model-based predictive control algorithm is developed to maintain normoglycemia in the Type I diabetic patient using a closed-loop insulin infusion pump. Utilizing compartmental modeling techniques, a fundamental model of the diabetic patient is constructed. The resulting nineteenth-order nonlinear pharmacokinetic-pharmacodynamic representation is used in controller synthesis. Linear identification of an input-output model from noisy patient data is performed by filtering the impulse-response coefficients via projection onto the Laguerre basis. A linear model predictive controller is developed using the identified step response model. Controller performance for unmeasured disturbance rejection (50 g oral glucose tolerance test) is examined. Glucose setpoint tracking performance is improved by designing a second controller which substitutes a more detailed internal model including state-estimation and a Kalman filter for the input-output representation. The state-estimating controller maintains glucose within 15 mg/dl of the setpoint in the presence of measurement noise. Under noise-free conditions, the model-based predictive controller using state estimation outperforms an internal model controller from literature (49.4% reduction in undershoot and 45.7% reduction in settling time). These results demonstrate the potential use of predictive algorithms for blood glucose control in an insulin infusion pump.

Entities:  

Mesh:

Substances:

Year:  1999        PMID: 9932336     DOI: 10.1109/10.740877

Source DB:  PubMed          Journal:  IEEE Trans Biomed Eng        ISSN: 0018-9294            Impact factor:   4.538


  91 in total

1.  Development of a multi-parametric model predictive control algorithm for insulin delivery in type 1 diabetes mellitus using clinical parameters.

Authors:  M W Percival; Y Wang; B Grosman; E Dassau; H Zisser; L Jovanovič; F J Doyle
Journal:  J Process Control       Date:  2011-03-01       Impact factor: 3.666

2.  A switching control strategy for the attenuation of blood glucose disturbances.

Authors:  Mihalis G Markakis; Georgios D Mitsis; George P Papavassilopoulos; Petros A Ioannou; Vasilis Z Marmarelis
Journal:  Optim Control Appl Methods       Date:  2011       Impact factor: 2.530

Review 3.  Toward closing the loop: an update on insulin pumps and continuous glucose monitoring systems.

Authors:  Tandy Aye; Jen Block; Bruce Buckingham
Journal:  Endocrinol Metab Clin North Am       Date:  2010-09       Impact factor: 4.741

4.  Anticipating the next meal using meal behavioral profiles: a hybrid model-based stochastic predictive control algorithm for T1DM.

Authors:  C S Hughes; S D Patek; M Breton; B P Kovatchev
Journal:  Comput Methods Programs Biomed       Date:  2010-06-19       Impact factor: 5.428

5.  Prediction of blood glucose level of type 1 diabetics using response surface methodology and data mining.

Authors:  M Yamaguchi; C Kaseda; K Yamazaki; M Kobayashi
Journal:  Med Biol Eng Comput       Date:  2006-06-03       Impact factor: 2.602

Review 6.  The future of open- and closed-loop insulin delivery systems.

Authors:  Terry G Farmer; Thomas F Edgar; Nicholas A Peppas
Journal:  J Pharm Pharmacol       Date:  2008-01       Impact factor: 3.765

Review 7.  Glucose-Responsive Insulin and Delivery Systems: Innovation and Translation.

Authors:  Jinqiang Wang; Zejun Wang; Jicheng Yu; Anna R Kahkoska; John B Buse; Zhen Gu
Journal:  Adv Mater       Date:  2019-08-18       Impact factor: 30.849

8.  Velocity-weighting & velocity-penalty MPC of an artificial pancreas: Improved safety & performance.

Authors:  Ravi Gondhalekar; Eyal Dassau; Francis J Doyle
Journal:  Automatica (Oxf)       Date:  2018-03-20       Impact factor: 5.944

9.  Periodic zone-MPC with asymmetric costs for outpatient-ready safety of an artificial pancreas to treat type 1 diabetes.

Authors:  Ravi Gondhalekar; Eyal Dassau; Francis J Doyle
Journal:  Automatica (Oxf)       Date:  2016-06-01       Impact factor: 5.944

Review 10.  Pharmacokinetic/pharmacodynamic modelling in diabetes mellitus.

Authors:  Cornelia B Landersdorfer; William J Jusko
Journal:  Clin Pharmacokinet       Date:  2008       Impact factor: 6.447

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.