Literature DB >> 28579655

Development of tunable miniature piezoelectric-based scanners validated by the combination of two scanners in a direct image relay technique.

Adam Harbi Shadfan1, Michal Emanuel Pawlowski1, Tomasz S Tkaczyk1,2.   

Abstract

Miniature piezoelectric actuators are commonly used as a compact means to relay images for numerous endoscopic applications. These scanners normally consist of an electrically driven lead zirconate titanate (PZT) tube that oscillates an optical fiber at its resonant frequency. The diameter and length of the PZT and fiber, the attachment of the fiber to the PZT, as well as the driving signal determine the main characteristics of the scan-frequency and amplitude of vibration. We present a new, robust, and repeatable method for producing miniature PZT actuators. The described technology allows for continuous tuning of the scanner mechanical properties during the assembly stage, enabling adjustment of resonant frequency and subsequent amplitude of vibration without a priori knowledge of the fiber's mechanical properties. The method consists of manufacturing high-precision fiber-holding plastic inserts with diamond turning lathes that allow for the fiber length to be quickly varied and locked during operation in order to meet the preferred performance. This concept of tuned PZTs was demonstrated with an imaging technique that combined two scanners oscillating in unison at the ends of a single optical fiber to relay images without the need to correlate the driving signal with a detector.

Entities:  

Keywords:  diamond machining; dual scanning imaging; endoscopy; micromachining; optical scanning

Year:  2016        PMID: 28579655      PMCID: PMC5450973          DOI: 10.1117/1.OE.55.1.013104

Source DB:  PubMed          Journal:  Opt Eng        ISSN: 0091-3286


  14 in total

Review 1.  Scanning fiber endoscopy with highly flexible, 1 mm catheterscopes for wide-field, full-color imaging.

Authors:  Cameron M Lee; Christoph J Engelbrecht; Timothy D Soper; Fritjof Helmchen; Eric J Seibel
Journal:  J Biophotonics       Date:  2010-06       Impact factor: 3.207

Review 2.  Fiber-optic fluorescence imaging.

Authors:  Benjamin A Flusberg; Eric D Cocker; Wibool Piyawattanametha; Juergen C Jung; Eunice L M Cheung; Mark J Schnitzer
Journal:  Nat Methods       Date:  2005-12       Impact factor: 28.547

3.  Two-dimensional scanning realized by an asymmetry fiber cantilever driven by single piezo bender actuator for optical coherence tomography.

Authors:  Tong Wu; Zhihua Ding; Kai Wang; Minghui Chen; Chuan Wang
Journal:  Opt Express       Date:  2009-08-03       Impact factor: 3.894

4.  Compact piezoelectric transducer fiber scanning probe for optical coherence tomography.

Authors:  Ning Zhang; Tsung-Han Tsai; Osman O Ahsen; Kaicheng Liang; Hsiang-Chieh Lee; Ping Xue; Xingde Li; James G Fujimoto
Journal:  Opt Lett       Date:  2014-01-15       Impact factor: 3.776

5.  Varifocal MOEMS fiber scanner for confocal endomicroscopy.

Authors:  Tobias Meinert; Niklas Weber; Hans Zappe; Andreas Seifert
Journal:  Opt Express       Date:  2014-12-15       Impact factor: 3.894

6.  Fiber-optic raster scanning two-photon endomicroscope using a tubular piezoelectric actuator.

Authors:  Dukho Do; Hongki Yoo; Dae-Gab Gweon
Journal:  J Biomed Opt       Date:  2014-06       Impact factor: 3.170

7.  Development of 2D Microdisplay Using an Integrated Microresonating Waveguide Scanning System.

Authors:  Wei-Shu Hua; Wei-Chih Wang; Wen-Jong Wu; Chi Leung Tsui; Wei Cui; Wen-Pin Shih
Journal:  J Intell Mater Syst Struct       Date:  2011-09       Impact factor: 2.569

Review 8.  Systematic review of outcomes following observational and operative endoscopic middle ear surgery.

Authors:  Elliott D Kozin; Shawn Gulati; Alyson B Kaplan; Ashton E Lehmann; Aaron K Remenschneider; Lukas D Landegger; Michael S Cohen; Daniel J Lee
Journal:  Laryngoscope       Date:  2014-11-24       Impact factor: 3.325

Review 9.  Advanced technologies for gastrointestinal endoscopy.

Authors:  Pietro Valdastri; Massimiliano Simi; Robert J Webster
Journal:  Annu Rev Biomed Eng       Date:  2012-05-22       Impact factor: 9.590

10.  Semi-resonant operation of a fiber-cantilever piezotube scanner for stable optical coherence tomography endoscope imaging.

Authors:  Sucbei Moon; Sang-Won Lee; Marc Rubinstein; Brian J F Wong; Zhongping Chen
Journal:  Opt Express       Date:  2010-09-27       Impact factor: 3.894

View more