Literature DB >> 24562102

Compact piezoelectric transducer fiber scanning probe for optical coherence tomography.

Ning Zhang, Tsung-Han Tsai, Osman O Ahsen, Kaicheng Liang, Hsiang-Chieh Lee, Ping Xue, Xingde Li, James G Fujimoto.   

Abstract

We developed a compact, optical fiber scanning piezoelectric transducer (PZT) probe for endoscopic and minimally invasive optical coherence tomography (OCT). Compared with previous forward-mount fiber designs, we present a reverse-mount design that achieves a shorter rigid length. The fiber was mounted at the proximal end of a quadruple PZT tube and scanned inside the hollow PZT tube to reduce the probe length. The fiber resonant frequency was 338 Hz using a 17-mm-long fiber. A 0.9 mm fiber deflection was achieved with a driving amplitude of 35 V. Using a GRIN lens-based optical design with a 1.3× magnification, a ∼6 μm spot was scanned over a 1.2 mm diameter field. The probe was encased in a metal hypodermic tube with a ∼25 mm rigid length and covered with a 3.2 mm outer diameter (OD) plastic sheath. Imaging was performed with a swept source OCT system based on a Fourier domain modelocked laser (FDML) light source at a 240 kHz axial scan rate and 8 μm axial resolution (in air). En face OCT imaging of skin in vivo and human colon ex vivo was demonstrated.

Entities:  

Mesh:

Year:  2014        PMID: 24562102      PMCID: PMC5875689          DOI: 10.1364/OL.39.000186

Source DB:  PubMed          Journal:  Opt Lett        ISSN: 0146-9592            Impact factor:   3.776


  13 in total

1.  Unique features of optical scanning, single fiber endoscopy.

Authors:  Eric J Seibel; Quinn Y J Smithwick
Journal:  Lasers Surg Med       Date:  2002       Impact factor: 4.025

2.  Rapid-scanning forward-imaging miniature endoscope for real-time optical coherence tomography.

Authors:  Xiumei Liu; Michael J Cobb; Yuchuan Chen; Michael B Kimmey; Xingde Li
Journal:  Opt Lett       Date:  2004-08-01       Impact factor: 3.776

3.  Forward imaging OCT endoscopic catheter based on MEMS lens scanning.

Authors:  Hyeon-Cheol Park; Cheol Song; Minseok Kang; Yong Jeong; Ki-Hun Jeong
Journal:  Opt Lett       Date:  2012-07-01       Impact factor: 3.776

4.  Low-voltage polymer-based scanning cantilever for in vivo optical coherence tomography.

Authors:  Yuli Wang; Mark Bachman; Guann-Pyng Li; Shuguang Guo; Brian J F Wong; Zhongping Chen
Journal:  Opt Lett       Date:  2005-01-01       Impact factor: 3.776

5.  Optical coherence tomography.

Authors:  D Huang; E A Swanson; C P Lin; J S Schuman; W G Stinson; W Chang; M R Hee; T Flotte; K Gregory; C A Puliafito
Journal:  Science       Date:  1991-11-22       Impact factor: 47.728

6.  Integrated multimodal endomicroscopy platform for simultaneous en face optical coherence and two-photon fluorescence imaging.

Authors:  Jiefeng Xi; Yongping Chen; Yuying Zhang; Kartikeya Murari; Ming-Jun Li; Xingde Li
Journal:  Opt Lett       Date:  2012-02-01       Impact factor: 3.776

7.  High speed optical coherence microscopy with autofocus adjustment and a miniaturized endoscopic imaging probe.

Authors:  Aaron D Aguirre; Juergen Sawinski; Shu-Wei Huang; Chao Zhou; Winfried Denk; James G Fujimoto
Journal:  Opt Express       Date:  2010-03-01       Impact factor: 3.894

8.  Comprehensive microscopy of the esophagus in human patients with optical frequency domain imaging.

Authors:  Melissa J Suter; Benjamin J Vakoc; Patrick S Yachimski; Milen Shishkov; Gregory Y Lauwers; Mari Mino-Kenudson; Brett E Bouma; Norman S Nishioka; Guillermo J Tearney
Journal:  Gastrointest Endosc       Date:  2008-10       Impact factor: 9.427

9.  Semi-resonant operation of a fiber-cantilever piezotube scanner for stable optical coherence tomography endoscope imaging.

Authors:  Sucbei Moon; Sang-Won Lee; Marc Rubinstein; Brian J F Wong; Zhongping Chen
Journal:  Opt Express       Date:  2010-09-27       Impact factor: 3.894

10.  Piezoelectric-transducer-based miniature catheter for ultrahigh-speed endoscopic optical coherence tomography.

Authors:  Tsung-Han Tsai; Benjamin Potsaid; Martin F Kraus; Chao Zhou; Yuankai K Tao; Joachim Hornegger; James G Fujimoto
Journal:  Biomed Opt Express       Date:  2011-07-29       Impact factor: 3.732

View more
  16 in total

1.  Ultrahigh speed en face OCT capsule for endoscopic imaging.

Authors:  Kaicheng Liang; Giovanni Traverso; Hsiang-Chieh Lee; Osman Oguz Ahsen; Zhao Wang; Benjamin Potsaid; Michael Giacomelli; Vijaysekhar Jayaraman; Ross Barman; Alex Cable; Hiroshi Mashimo; Robert Langer; James G Fujimoto
Journal:  Biomed Opt Express       Date:  2015-03-05       Impact factor: 3.732

2.  Correction of circumferential and longitudinal motion distortion in high-speed catheter/endoscope-based optical coherence tomography.

Authors:  Tan Huu Nguyen; Osman Oguz Ahsen; Kaicheng Liang; Jason Zhang; Hiroshi Mashimo; James G Fujimoto
Journal:  Biomed Opt Express       Date:  2020-12-09       Impact factor: 3.732

3.  Colposcopic imaging using visible-light optical coherence tomography.

Authors:  Lian Duan; Michael D McRaven; Wenzhong Liu; Xiao Shu; Jianmin Hu; Cheng Sun; Ronald S Veazey; Thomas J Hope; Hao F Zhang
Journal:  J Biomed Opt       Date:  2017-05-01       Impact factor: 3.170

4.  Endoscopic optical coherence tomography: technologies and clinical applications [Invited].

Authors:  Michalina J Gora; Melissa J Suter; Guillermo J Tearney; Xingde Li
Journal:  Biomed Opt Express       Date:  2017-04-07       Impact factor: 3.732

5.  Endoscopic forward-viewing optical coherence tomography and angiography with MHz swept source.

Authors:  Kaicheng Liang; Osman O Ahsen; Zhao Wang; Hsiang-Chieh Lee; Wenxuan Liang; Benjamin M Potsaid; Tsung-Han Tsai; Michael G Giacomelli; Vijaysekhar Jayaraman; Hiroshi Mashimo; Xingde Li; James G Fujimoto
Journal:  Opt Lett       Date:  2017-08-15       Impact factor: 3.776

6.  Circumferential-scanning endoscopic optical coherence tomography probe based on a circular array of six 2-axis MEMS mirrors.

Authors:  Site Luo; Dan Wang; Jianyu Tang; Liang Zhou; Can Duan; Donglin Wang; Hao Liu; Yu Zhu; Guoxing Li; Hui Zhao; Yuqing Wu; Xin An; Xinling Li; Yabing Liu; Li Huo; Huikai Xie
Journal:  Biomed Opt Express       Date:  2018-04-05       Impact factor: 3.732

7.  Development of tunable miniature piezoelectric-based scanners validated by the combination of two scanners in a direct image relay technique.

Authors:  Adam Harbi Shadfan; Michal Emanuel Pawlowski; Tomasz S Tkaczyk
Journal:  Opt Eng       Date:  2016-01-18

8.  Effect of an Added Mass on the Vibration Characteristics for Raster Scanning of a Cantilevered Optical Fiber.

Authors:  Kelli C Kiekens; David Vega; Harrison T Thurgood; Dominique Galvez; Davis J McGregor; Travis W Sawyer; Jennifer K Barton
Journal:  J Eng Sci Med Diagn Ther       Date:  2021-04-22

9.  Software-Based Phase Control, Video-Rate Imaging, and Real-Time Mosaicing With a Lissajous-Scanned Confocal Microscope.

Authors:  Nathan O Loewke; Zhen Qiu; Michael J Mandella; Robert Ertsey; Adrienne Loewke; Lisa A Gunaydin; Eben L Rosenthal; Christopher H Contag; Olav Solgaard
Journal:  IEEE Trans Med Imaging       Date:  2019-09-27       Impact factor: 10.048

10.  Expanding Functionality of Commercial Optical Coherence Tomography Systems by Integrating a Custom Endoscope.

Authors:  Weston A Welge; Jennifer K Barton
Journal:  PLoS One       Date:  2015-09-29       Impact factor: 3.240

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.