Effect of decentration of wavefront-corrected intraocular lenses on the higher-order aberrations of the eye.

Li Wang1, Douglas D Koch.   

Abstract

OBJECTIVE: To evaluate the theoretical effect of decentration of aspherical intraocular lenses (IOLs) and wavefront-corrected IOLs up to the sixth order on higher-order aberrations (HOAs) (third through sixth order) of the eye.
METHODS: An aspherical IOL with HOAs of fourth-order spherical aberrations only (-0.287 microm with a 6-mm pupil) and a wavefront-corrected IOL with HOAs of equal magnitude and opposite from the corneal HOAs were created and laterally shifted up to 1 mm to simulate decentered IOLs. The residual HOAs for pupils of 3 to 6 mm were calculated by combining the HOAs from the cornea and the decentered IOL. Based on the residual HOAs, optical quality was rated by 3 criteria: the Marechal criterion, a diffraction-limited optical system with an aberration less than lambda/14; P(10), the lower 10th percentile of the corneal HOAs in this study group; and decreased HOA, residual ocular HOAs less than the corresponding corneal HOAs.
RESULTS: Simulated implantation of the aspherical IOLs and wavefront-corrected IOLs was performed in 154 eyes of 94 patients aged 40 to 80 years. For a centered aspherical IOL and a 6-mm pupil, no eyes met the Marechal criterion, and the P(10) and decreased-HOA criteria were met by 46% and 93% of eyes, respectively. For a 6-mm pupil, the required centration was 0.47 mm to meet the decreased-HOA criterion in 50% of eyes. With a wavefront-corrected IOL and a 6-mm pupil, the centrations required to meet the criteria for 90% of eyes were 0.04 mm for the Marechal criterion, 0.36 mm for P(10), and 0.48 mm for the decreased-HOA criterion.
CONCLUSION: Excellent centration is required to maximize the visual outcome of wavefront-corrected IOLs. CLINICAL RELEVANCE: With current surgical techniques, implantation of aspherical IOLs and wavefront-corrected IOLs will reduce total ocular HOAs below corneal HOAs in approximately 45% and 86% of eyes (6-mm pupil), respectively.

Entities:  

Mesh:

Year:  2005        PMID: 16157803     DOI: 10.1001/archopht.123.9.1226

Source DB:  PubMed          Journal:  Arch Ophthalmol        ISSN: 0003-9950


  14 in total

1.  Comparison of contrast sensitivity, depth of field and ocular wavefront aberrations in eyes with an IOL with zero versus positive spherical aberration.

Authors:  Jay S Pepose; Mujtaba A Qazi; Keith H Edwards; Jeff P Sanderson; Edwin J Sarver
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2009-03-11       Impact factor: 3.117

2.  Custom optimization of intraocular lens asphericity.

Authors:  Douglas D Koch; Li Wang
Journal:  Trans Am Ophthalmol Soc       Date:  2007

3.  Comparative study of visual function and ocular aberrations of two different one-piece designed hydrophilic acrylic intraocular lens.

Authors:  Yuxin Zhao; Zhaoxia Wang; Xia Tian; Xuehong Wang; Xining Gao
Journal:  Int Ophthalmol       Date:  2017-05-30       Impact factor: 2.031

Review 4.  [Iris suture fixation of posterior chamber lenses. New perspectives for an old technique].

Authors:  K Gerstmeyer; W Sekundo
Journal:  Ophthalmologe       Date:  2014-03       Impact factor: 1.059

5.  Spherical aberration reduction in nuclear cataracts.

Authors:  Jong-Hyuck Lee; Hun Gu Choo; Sun Woong Kim
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2016-03-17       Impact factor: 3.117

6.  Evaluation of actual retinal images produced by misaligned aspheric intraocular lenses in a model eye.

Authors:  Takashi Fujikado; Makoto Saika
Journal:  Clin Ophthalmol       Date:  2014-11-28

7.  Customized Clinical Practice Guidelines for Management of Adult Cataract in Iran.

Authors:  Zhaleh Rajavi; Mohammad Ali Javadi; Narsis Daftarian; Sare Safi; Farhad Nejat; Armin Shirvani; Hamid Ahmadieh; Saeid Shahraz; Hossein Ziaei; Hamidreza Moein; Behzad Fallahi Motlagh; Sepehr Feizi; Alireza Foroutan; Hassan Hashemi; Seyed Javad Hashemian; Mahmoud Jabbarvand; Mohammad Reza Jafarinasab; Farid Karimian; Hossein Mohammad-Rabei; Mehrdad Mohammadpour; Nader Nassiri; Mahmoodreza Panahi-Bazaz; Mohammad Reza Rohani; Mohammad Reza Sedaghat; Kourosh Sheibani
Journal:  J Ophthalmic Vis Res       Date:  2015 Oct-Dec

8.  Comparisons of the in-the-bag stabilities of single-piece and three-piece intraocular lenses for age-related cataract patients: a randomized controlled trial.

Authors:  Xiaojian Zhong; Erping Long; Wan Chen; Wu Xiang; Zhaochuan Liu; Hui Chen; Jingjing Chen; Zhuoling Lin; Haotian Lin; Weirong Chen
Journal:  BMC Ophthalmol       Date:  2016-07-08       Impact factor: 2.209

9.  Keratoconic eyes with stable corneal tomography could benefit more from custom intraocular lens design than normal eyes.

Authors:  Simon Schröder; Timo Eppig; Weidi Liu; Jens Schrecker; Achim Langenbucher
Journal:  Sci Rep       Date:  2019-03-05       Impact factor: 4.379

10.  Comparison of retinal image quality with spherical and customized aspheric intraocular lenses.

Authors:  Huanqing Guo; Alexander V Goncharov; Chris Dainty
Journal:  Biomed Opt Express       Date:  2012-03-01       Impact factor: 3.732