Literature DB >> 12686231

Impact of a modified optic design on visual function: clinical comparative study.

Ulrich Mester1, Patrick Dillinger, Nicola Anterist.   

Abstract

PURPOSE: To determine whether implantation of an intraocular lens (IOL) with a modified anterior surface designed to compensate for the positive spherical aberration of the cornea in eyes of cataract patients results in improved pseudophakic quality of vision.
SETTING: Department of Ophthalmology, Bundesknappschaft's Hospital, Sulzbach, Germany.
METHODS: In an intraindividual randomized study of 45 patients with bilateral cataract, an IOL with a modified anterior surface (Tecnis Z9000, Pharmacia) was compared with a biconvex lens with spherical surfaces (SI-40, Allergan). All patients had bilateral cataract surgery; in 1 eye the Z9000 IOL was implanted and in the other, the SI-40 IOL. After 1 and 3 months, the following investigations were performed: assessment of the anterior and posterior segments including IOL decentration and tilt, pupil size, high- and low-contrast visual acuities, photopic and mesopic contrast sensitivities, and wavefront aberration of the cornea and eye.
RESULTS: Thirty-seven patients were examined at all follow-up visits. Although the eyes with the Z9000 IOL had significantly better best corrected visual acuity after 3 months, the improved quality of vision was more apparent when assessing low-contrast visual acuity and contrast sensitivity. Wavefront measurements revealed no significant spherical aberration in eyes with a Z9000 IOL but significantly positive spherical aberration in eyes with an SI-40 IOL.
CONCLUSIONS: The clinical results confirm the theoretical preclinical calculations that the spherical aberration of the eye after cataract surgery can be eliminated by modifying the anterior surface of the IOL. The Tecnis Z9000 lens compensates for the positive spherical aberration in older eyes. This leads to a significant improvement, particularly in contrast sensitivity and mesopic visual quality.

Entities:  

Mesh:

Year:  2003        PMID: 12686231     DOI: 10.1016/s0886-3350(02)01983-1

Source DB:  PubMed          Journal:  J Cataract Refract Surg        ISSN: 0886-3350            Impact factor:   3.351


  32 in total

1.  [Clinical results of the aspheric intraocular lens FY-60AD (Hoya) with particular respect to decentration and tilt].

Authors:  U Mester; S Heinen; H Kaymak
Journal:  Ophthalmologe       Date:  2010-09       Impact factor: 1.059

2.  Visual and optical performance of eyes with different corneal spherical aberration implanted with aspheric intraocular lens.

Authors:  Xian-Hui Gong; Qin-Xiang Zheng; Na Wang; Ding Chen; Juan Zhao; Jin Li; Yun-E Zhao
Journal:  Int J Ophthalmol       Date:  2012-06-18       Impact factor: 1.779

3.  Star testing: a novel evaluation of intraocular lens optical quality.

Authors:  L Mitchell; A C B Molteno; T H Bevin; G Sanderson
Journal:  Br J Ophthalmol       Date:  2006-05       Impact factor: 4.638

Review 4.  [Application of wavefront analysis in clinical and scientific settings. From irregular astigmatism to aberrations of a higher order--Part II: examples].

Authors:  J Bühren; T Kohnen
Journal:  Ophthalmologe       Date:  2007-11       Impact factor: 1.059

5.  Comparison of contrast sensitivity, depth of field and ocular wavefront aberrations in eyes with an IOL with zero versus positive spherical aberration.

Authors:  Jay S Pepose; Mujtaba A Qazi; Keith H Edwards; Jeff P Sanderson; Edwin J Sarver
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2009-03-11       Impact factor: 3.117

6.  [Aberration corrected intraocular lens for microincision cataract surgery (MICS). Intraindividual comparison with a conventional lens - 1-year follow-up].

Authors:  M Möglich; H Häberle; D T Pham; C Wirbelauer
Journal:  Ophthalmologe       Date:  2009-10       Impact factor: 1.059

7.  [The aspheric blue light filter IOL AcrySof IQ compared to the AcrySof SA60AT : influence of IOL power, pupil diameter, and corneal asphericity on postoperative spherical aberration].

Authors:  U Mester; H Kaymak
Journal:  Ophthalmologe       Date:  2008-11       Impact factor: 1.059

8.  Higher order aberration comparison between two aspherical intraocular lenses: MC6125AS and Akreos advanced optics.

Authors:  Mohammad Taher Rajabi; Sara Korouji; Mahgol Farjadnia; Mohammad Naderan; Mohammad Bagher Rajabi; Bahram Khosravi; Seyed Mehdi Tabatabaie
Journal:  Int J Ophthalmol       Date:  2015-06-18       Impact factor: 1.779

9.  Comparative study of visual function and ocular aberrations of two different one-piece designed hydrophilic acrylic intraocular lens.

Authors:  Yuxin Zhao; Zhaoxia Wang; Xia Tian; Xuehong Wang; Xining Gao
Journal:  Int Ophthalmol       Date:  2017-05-30       Impact factor: 2.031

10.  [First results with a new aberration correcting bifocal intraocular lens].

Authors:  H Kaymak; U Mester
Journal:  Ophthalmologe       Date:  2007-12       Impact factor: 1.059

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.