Literature DB >> 23288762

A comparison of the noise generated from different types of knee prostheses.

James W Pritchett1.   

Abstract

After total knee arthroplasty (TKA), patients may experience noise from their replaced knee. A prospective study was conducted with 465 (930 knees) patients to evaluate noise after bilateral TKA. A different randomly selected prosthesis was used on each side. The prostheses used were medial pivot (MP), anterior and posterior cruciate ligament retaining (ACL-PCL), posterior cruciate ligament retaining (PCL), posterior cruciate-substituting (PS), or mobile bearing (MB). The evaluation included the patients' responses to questions about noise after both their TKAs. Noise-related symptoms were reported by 12% of the patients with MP prostheses, 4% of patients with ACL-PCL, 31% of patients with PCL, 33% of patients with PS, and 42% of patients with MB. Occasionally, patients were concerned or dissatisfied with this phenomenon. Noise was less common with TKAs that used MP and ACL-PCL knee prostheses than with TKAs that used other prostheses. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

Entities:  

Mesh:

Year:  2012        PMID: 23288762     DOI: 10.1055/s-0032-1319779

Source DB:  PubMed          Journal:  J Knee Surg        ISSN: 1538-8506            Impact factor:   2.757


  7 in total

1.  Bicruciate-retaining Total Knee Replacement Provides Satisfactory Function and Implant Survivorship at 23 Years.

Authors:  James W Pritchett
Journal:  Clin Orthop Relat Res       Date:  2015-02-27       Impact factor: 4.176

2.  Analysis of different bicruciate-retaining tibial prosthesis design using a three dimension finite element model.

Authors:  Peiheng He; Xing Li; Shuai Huang; Minghao Liu; Weizhi Chen; Dongliang Xu
Journal:  Am J Transl Res       Date:  2017-05-15       Impact factor: 4.060

3.  CORR Insights®: What Is the Frequency of Noise Generation in Modern Knee Arthroplasty and Is It Associated With Residual Symptoms?

Authors:  Tae Kyun Kim
Journal:  Clin Orthop Relat Res       Date:  2016-02-24       Impact factor: 4.176

4.  Bi-cruciate retaining total knee arthroplasty: a systematic literature review of clinical outcomes.

Authors:  Christoph Kolja Boese; Stephen Ebohon; Christian Ries; Diarmuid De Faoite
Journal:  Arch Orthop Trauma Surg       Date:  2020-10-13       Impact factor: 3.067

5.  What Is the Frequency of Noise Generation in Modern Knee Arthroplasty and Is It Associated With Residual Symptoms?

Authors:  Denis Nam; Toby Barrack; Ryan M Nunley; Robert L Barrack
Journal:  Clin Orthop Relat Res       Date:  2017-01       Impact factor: 4.176

6.  Comparison of outcomes after bilateral simultaneous total knee arthroplasty using posterior-substituting versus cruciate-retaining prostheses.

Authors:  Hong-Guang Liu; Wei Zhu; Zhen-Xiang Zhang
Journal:  Saudi Med J       Date:  2015-02       Impact factor: 1.484

7.  Knee Squeaking Secondary to Intra-articular Nonabsorbable Suture: A Report of 2 Cases.

Authors:  Jake Zarah; Zaira S Chaudhry; Kevin B Freedman; Paul Marchetto; Sommer Hammoud
Journal:  Orthop J Sports Med       Date:  2017-07-13
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.