A combined RSA and FE study of the implanted proximal tibia: correlation of the post-operative mechanical environment with implant migration.

A Perillo-Marcone1, L Ryd, K Johnsson, M Taylor.   

Abstract

There is strong evidence to suggest that inducible displacements, migration and implant loosening are closely related to the initial mechanical environment of the implanted tibia. If this is true, then it should be possible to predict the likelihood of implant migration using patient-specific finite element models. Finite element models of the proximal implanted tibiae were analysed based on pre-operative quantitative computed tomography data of four patients entered into a radiographic migration study. These four patients were also part of an radiostereometric analysis (RSA) study. A variety of load cases were analysed and the risk of bone failure determined for a 2 mm layer of bone immediately beneath the tibial tray. The results were compared with the RSA data measured 1 year post-operatively for each patient. For each patient, an appropriate load case was selected based on patient weight and on the varus-valgus migrations observed in the migration study. The two patients with press-fit implants were predicted to have the highest risk of failure and were found to migrate the most. The two patients with bonded implants (one HA coated and one cemented) were found to have a low risk of failure and these implants migrated the least. This study suggests that the degree of implant migration is dependent on the initial mechanical environment and can be determined using patient-specific finite element analysis.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 15212926     DOI: 10.1016/j.jbiomech.2003.12.004

Source DB:  PubMed          Journal:  J Biomech        ISSN: 0021-9290            Impact factor:   2.712


  4 in total

Review 1.  Tibial component designs in primary total knee arthroplasty: should we reconsider all-polyethylene component?

Authors:  Tao Cheng; Xiaoyun Pan; Tao Liu; Xianlong Zhang
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2011-10-05       Impact factor: 4.342

2.  Finite element analysis: a comparison of an all-polyethylene tibial implant and its metal-backed equivalent.

Authors:  S M Thompson; D Yohuno; W N Bradley; A D Crocombe
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2015-12-22       Impact factor: 4.342

3.  Analysis of different bicruciate-retaining tibial prosthesis design using a three dimension finite element model.

Authors:  Peiheng He; Xing Li; Shuai Huang; Minghao Liu; Weizhi Chen; Dongliang Xu
Journal:  Am J Transl Res       Date:  2017-05-15       Impact factor: 4.060

4.  A Numerical Investigation into the Effects of Overweight and Obesity on Total Knee Arthroplasty.

Authors:  Changjiang Wang; Yuan Guo; Junfen Shi; Weiyi Chen
Journal:  J Healthc Eng       Date:  2017-05-29       Impact factor: 2.682