Literature DB >> 28534290

Wear predictions for UHMWPE material with various surface properties used on the femoral component in total knee arthroplasty: a computational simulation study.

Kyoung-Tak Kang1, Juhyun Son1, Ho-Joong Kim2, Changhyun Baek3, Oh-Ryong Kwon4, Yong-Gon Koh5.   

Abstract

The wear of ultrahigh-molecular weight polyethylene (UHMWPE) tibial inserts in total knee arthroplasty (TKA) remains a major limitation that hinders the longevity of clinically successful devices. Surface properties significantly affect the overall performance of TKA, and surface modification with mechanically and chemically stable materials is an effective method for overcoming the wear of TKA. However, wear tests are not cost-efficient or time-efficient; thus, the effects of geometric, loading, and alignment perturbations are often evaluated via parametric studies. Computational wear prediction using a finite element (FE) model followed by validation through comparison with experimental data is effective for assessing new prosthetic designs or surface change methods prior to functional testing and surgical implementation. The aim of this study was to evaluate the weight loss, wear depth, and kinematics for different surface properties, including nanostructured diamond (NSD), diamond-like carbon (DLC), titanium-nitride (TiN), and oxidized zirconium (OxZr) on femoral components in TKA using FE analysis under gait-cycle loading conditions. Weight loss and wear depth were lowest with OxZr followed by TiN, NSD, and DLC. However, the DLC femoral component did not show any improvement in wear rate compared to an uncoated cobalt-chromium (Co-Cr) femoral component. Not all surface changes applied in this study did lead to improvement in wear performance. However, this study demonstrates the potential of OxZr and TiN for reducing UHMWPE wear and offers new insights into the effects of wear on TKA.

Entities:  

Mesh:

Substances:

Year:  2017        PMID: 28534290     DOI: 10.1007/s10856-017-5916-5

Source DB:  PubMed          Journal:  J Mater Sci Mater Med        ISSN: 0957-4530            Impact factor:   3.896


  21 in total

1.  Effects of in vitro wear of machined and molded UHMWPE tibial inserts on TKR kinematics.

Authors:  L C Benson; J D DesJardins; M LaBerge
Journal:  J Biomed Mater Res       Date:  2001

2.  Investigation of wear of knee prostheses in a new displacement/force-controlled simulator.

Authors:  P I Barnett; H M J McEwen; D D Auger; M H Stone; E Ingham; J Fisher
Journal:  Proc Inst Mech Eng H       Date:  2002       Impact factor: 1.617

3.  Wear, debris, and biologic activity of cross-linked polyethylene in the knee: benefits and potential concerns.

Authors:  John Fisher; Hannah M J McEwen; Joanne L Tipper; Alison L Galvin; Jo Ingram; Amir Kamali; Martin H Stone; Eileen Ingham
Journal:  Clin Orthop Relat Res       Date:  2004-11       Impact factor: 4.176

4.  Comparison of deformable and elastic foundation finite element simulations for predicting knee replacement mechanics.

Authors:  Jason P Halloran; Sarah K Easley; Anthony J Petrella; Paul J Rullkoetter
Journal:  J Biomech Eng       Date:  2005-10       Impact factor: 2.097

5.  Predicting knee replacement damage in a simulator machine using a computational model with a consistent wear factor.

Authors:  Dong Zhao; Hideyuki Sakoda; W Gregory Sawyer; Scott A Banks; Benjamin J Fregly
Journal:  J Biomech Eng       Date:  2008-02       Impact factor: 2.097

6.  A knee simulating machine for performance evaluation of total knee replacements.

Authors:  P S Walker; G W Blunn; D R Broome; J Perry; A Watkins; S Sathasivam; M E Dewar; J P Paul
Journal:  J Biomech       Date:  1997-01       Impact factor: 2.712

7.  Wear simulation of total hip prostheses with polyethylene against CoCr, alumina and diamond-like carbon.

Authors:  V Saikko; T Ahlroos; O Calonius; J Keränen
Journal:  Biomaterials       Date:  2001-06       Impact factor: 12.479

8.  Importance of joint line preservation in unicompartmental knee arthroplasty: Finite element analysis.

Authors:  Oh-Ryong Kwon; Kyoung-Tak Kang; Juhyun Son; Dong-Suk Suh; Changhyun Baek; Yong-Gon Koh
Journal:  J Orthop Res       Date:  2016-05-12       Impact factor: 3.494

Review 9.  Mechanism and clinical significance of wear debris-induced osteolysis.

Authors:  H C Amstutz; P Campbell; N Kossovsky; I C Clarke
Journal:  Clin Orthop Relat Res       Date:  1992-03       Impact factor: 4.176

10.  Preliminary tribological evaluation of nanostructured diamond coatings against ultra-high molecular weight polyethylene.

Authors:  Michael R Hill; Shane A Catledge; Valeriy Konovalov; William C Clem; Shafiul A Chowdhury; Brandon S Etheridge; Andrei Stanishevsky; Jack E Lemons; Yogesh K Vohra; Alan W Eberhardt
Journal:  J Biomed Mater Res B Appl Biomater       Date:  2008-04       Impact factor: 3.368

View more
  5 in total

Review 1.  New alternate bearing surfaces in total hip arthroplasty: A review of the current literature.

Authors:  Preston W Grieco; Scott Pascal; Jared M Newman; Neil V Shah; Sarah G Stroud; Neil P Sheth; Aditya V Maheshwari
Journal:  J Clin Orthop Trauma       Date:  2017-10-27

2.  Influence of tibiofemoral congruency design on the wear of patient-specific unicompartmental knee arthroplasty using finite element analysis.

Authors:  Y-G Koh; K-M Park; H-Y Lee; K-T Kang
Journal:  Bone Joint Res       Date:  2019-04-02       Impact factor: 5.853

3.  Structure and Performance Attributes Optimization and Ranking of Gamma Irradiated Polymer Hybrids for Industrial Application.

Authors:  Suhail H Serbaya; Emad H Abualsauod; Mohammed Salem Basingab; Hatim Bukhari; Ali Rizwan; Malik Sajjad Mehmood
Journal:  Polymers (Basel)       Date:  2021-12-23       Impact factor: 4.329

4.  Prediction of wear performance in femoral and tibial conformity in patient-specific cruciate-retaining total knee arthroplasty.

Authors:  Yong-Gon Koh; Kyoung-Mi Park; Hwa-Yong Lee; Joon-Hee Park; Kyoung-Tak Kang
Journal:  J Orthop Surg Res       Date:  2020-01-22       Impact factor: 2.359

5.  Computational wear prediction of insert conformity and material on mobile-bearing unicompartmental knee arthroplasty.

Authors:  Y-G Koh; J-A Lee; H-Y Lee; H-J Kim; K-T Kang
Journal:  Bone Joint Res       Date:  2019-12-03       Impact factor: 5.853

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.