Investigation of wear of knee prostheses in a new displacement/force-controlled simulator.

P I Barnett1, H M J McEwen, D D Auger, M H Stone, E Ingham, J Fisher.   

Abstract

The performance of two knee simulators designed by ProSim (Manchester, UK) was evaluated by comparison of the wear seen in the press-fit condylar (PFC) Sigma (DePuy) knee prosthesis. Twelve specimens of the same design and manufacturing specification, were subjected to a wear test of 2 x 10(6) cycles duration using bovine serum as a lubricant. The anterior/posterior displacement and internal/external rotation inputs were based on the kinematics of the natural knee. International Standards Organization (ISO) standards were used for the flexion and axial load. The wear rates and wear scar areas were compared across all stations. The mean wear rates found were 17.6+/-5 mm3/10(6) cycles for stations 1 to 6 and 19.6+/-4 mm3/10(6) cycles for stations 7 to 12, resulting in an overall mean wear rate of 18.1+/-3 mm3/10(6) cycles. The differences between the two simulators were not significant. The average wear scar area seen on inserts from stations I to 6 was calculated at 32.4+/-1 per cent of the intended articulating surface. Similarly on stations 7 to 12 the average wear scar area was 30.7+/-3 per cent. The wear scars seen were a good physiological representation of those found from clinical explant data. This study has shown good repeatability from the simulator, both within and between the simulators.

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 11908483     DOI: 10.1243/0954411021536289

Source DB:  PubMed          Journal:  Proc Inst Mech Eng H        ISSN: 0954-4119            Impact factor:   1.617


  7 in total

1.  2009 Knee Society Presidential Guest Lecture: Polyethylene wear in total knees.

Authors:  John Fisher; Louise M Jennings; Alison L Galvin; Zhongmin M Jin; Martin H Stone; Eileen Ingham
Journal:  Clin Orthop Relat Res       Date:  2009-08-11       Impact factor: 4.176

2.  The choice of the femoral center of rotation affects material loss in total knee replacement wear testing - A parametric finite element study of ISO 14243-3.

Authors:  Steven P Mell; Markus A Wimmer; Hannah J Lundberg
Journal:  J Biomech       Date:  2019-03-23       Impact factor: 2.712

3.  Wear predictions for UHMWPE material with various surface properties used on the femoral component in total knee arthroplasty: a computational simulation study.

Authors:  Kyoung-Tak Kang; Juhyun Son; Ho-Joong Kim; Changhyun Baek; Oh-Ryong Kwon; Yong-Gon Koh
Journal:  J Mater Sci Mater Med       Date:  2017-05-22       Impact factor: 3.896

4.  CR TKA UHMWPE wear tested after artificial aging of the vitamin E treated gliding component by simulating daily patient activities.

Authors:  Jens Schwiesau; Bernhard Fritz; Ines Kutzner; Georg Bergmann; Thomas M Grupp
Journal:  Biomed Res Int       Date:  2014-11-20       Impact factor: 3.411

5.  The influence of simulator input conditions on the wear of total knee replacements: An experimental and computational study.

Authors:  Claire L Brockett; Abdellatif Abdelgaied; Tony Haythornthwaite; Catherine Hardaker; John Fisher; Louise M Jennings
Journal:  Proc Inst Mech Eng H       Date:  2016-05       Impact factor: 1.617

6.  A comparison between electromechanical and pneumatic-controlled knee simulators for the investigation of wear of total knee replacements.

Authors:  Abdellatif Abdelgaied; John Fisher; Louise M Jennings
Journal:  Proc Inst Mech Eng H       Date:  2017-03-25       Impact factor: 1.617

7.  PEEK and CFR-PEEK as alternative bearing materials to UHMWPE in a fixed bearing total knee replacement: An experimental wear study.

Authors:  Claire L Brockett; Silvia Carbone; John Fisher; Louise M Jennings
Journal:  Wear       Date:  2017-03-15       Impact factor: 3.892

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.